Needle Aligned Ultrasound Image-Guided Access Through Dual-Segment Array

被引:1
|
作者
Rahaman, Ashiqur [1 ,2 ]
Tang, Yichuan [1 ]
Gao, Shang [1 ]
Ma, Xihan [1 ]
Sorokin, Igor [3 ]
Zhang, Haichong K. [1 ,2 ,4 ]
机构
[1] Worcester Polytech Inst, Dept Robot Engn, Worcester, MA 01609 USA
[2] Worcester Polytech Inst, Dept Biomed Engn, Worcester, MA 01609 USA
[3] Univ Massachusetts, Med Sch, Dept Urol, Worcester, MA USA
[4] Worcester Polytech Inst, Dept Comp Sci, Worcester, MA 01609 USA
基金
美国国家卫生研究院;
关键词
Needles; Acoustic beams; Probes; Kidney; Imaging; Image segmentation; Visualization; Needle-image alignment; Percutaneous intervention; Ultrasound-guided intervention; Dual-segment array; PERCUTANEOUS NEPHROLITHOTOMY; VISUALIZATION; GUIDANCE; FREEHAND; BIOPSY; SYSTEM;
D O I
10.1109/TBME.2023.3260735
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Ultrasound (US) guided access for percutaneous nephrolithotomy (PCNL) is gaining popularity in the urology community as it reduces radiation risk. The most popular technique involves manual image-needle alignment. A misaligned needle however needs to be retracted and reinserted, resulting in a lengthened operation time and complications such as bleeding. These limitations can be mitigated through the co-registration between the US array and needle. The through-hole array concept provides the primary solution, including a hole at the center of the array. Because of the central opening, the image-needle alignment is achieved inherently. Previous literature has described applications that are limited to superficial and intravascular procedures, suggesting that developing a through-hole array for deeper target applications would be a new breakthrough. Objective. Here, we present a dual-segment array with a central opening. As the prototype development, two segments of 32-element arrays are combined with an open space of 10 mm in length in between them. Method. We conducted phantom and ex-vivo studies considering the target depth of the 80-100 mm range. The image quality and needle visibility are evaluated by comparing the signal-to-noise ratio (SNR), full width at half maximum (FWHM), and contrast-to-noise ratio (CNR) results measured with a no-hole linear array under equivalent conditions. An ex-vivo study is performed using porcine kidneys with ceramic balls embedded to evaluate the needle access accuracy. Results and conclusion.The mean needle access error of 20 trials is found to be 2.94$\pm$1.09 mm, suggesting its potential impact on realizing a simple and intuitive deep US image-guided access.
引用
收藏
页码:2645 / 2654
页数:10
相关论文
共 50 条
  • [21] Ultrasound Image-Guided Drug Delivery using a Spherically Focused Phased Array Transducer
    Margolis, Ryan
    Basavarajappa, Lokesh
    Li, Junjie
    Hoyt, Kenneth
    INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS 2021), 2021,
  • [22] Improvement of Tubular Permanent Magnet Machine Performance Using Dual-Segment Halbach Array
    Minh-Trung Duong
    Chun, Yon-Do
    Bang, Deok-Je
    ENERGIES, 2018, 11 (11)
  • [23] Ultrasound triggered image-guided drug delivery
    Bohmer, Marcel R.
    Klibanov, Alexander L.
    Tiemann, Klaus
    Hall, Christopher S.
    Gruell, Holger
    Steinbach, Oliver C.
    EUROPEAN JOURNAL OF RADIOLOGY, 2009, 70 (02) : 242 - 253
  • [24] Image-Guided Focused Ultrasound Surgery and Therapy
    Farahani, K.
    MEDICAL PHYSICS, 2016, 43 (06) : 3699 - 3700
  • [25] Image-guided control of a robot for medical ultrasound
    Abolmaesumi, P
    Salcudean, SE
    Zhu, WH
    Sirouspour, MR
    DiMaio, SP
    IEEE TRANSACTIONS ON ROBOTICS AND AUTOMATION, 2002, 18 (01): : 11 - 23
  • [26] An Ultrasound Probe Holder for Image-Guided Surgery
    Yousef, Basem Fayez
    Patel, Rajni V.
    Moallem, Mehrdad
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2008, 2 (02):
  • [27] Image-guided core needle biopsy for DCIS: Is this accurate?
    Rutstein, LA
    Johnson, R
    Poller, W
    Dabbs, D
    Rakitt, T
    Groblewski, J
    Tsung, A
    Kirchner, T
    Falk, J
    ANNALS OF SURGICAL ONCOLOGY, 2003, 10 (01) : S54 - S54
  • [28] Advances in Image-Guided Focused Ultrasound Applications
    de Senneville, B. Denis
    Payne, A.
    Lafon, C.
    Chen, H.
    MEDICAL PHYSICS, 2019, 46 (06) : E375 - E375
  • [29] A novel platform for image-guided ultrasound - Comments
    Skirboll, S
    Chang, SD
    Nimsky, C
    Sonntag, VKH
    Barnett, GH
    NEUROSURGERY, 2006, 58 (04) : 717 - 718
  • [30] Ultrasound image-guided core biopsy of the breast
    Klimberg, V. Suzanne
    Rivere, Amy