Needle Aligned Ultrasound Image-Guided Access Through Dual-Segment Array

被引:1
|
作者
Rahaman, Ashiqur [1 ,2 ]
Tang, Yichuan [1 ]
Gao, Shang [1 ]
Ma, Xihan [1 ]
Sorokin, Igor [3 ]
Zhang, Haichong K. [1 ,2 ,4 ]
机构
[1] Worcester Polytech Inst, Dept Robot Engn, Worcester, MA 01609 USA
[2] Worcester Polytech Inst, Dept Biomed Engn, Worcester, MA 01609 USA
[3] Univ Massachusetts, Med Sch, Dept Urol, Worcester, MA USA
[4] Worcester Polytech Inst, Dept Comp Sci, Worcester, MA 01609 USA
基金
美国国家卫生研究院;
关键词
Needles; Acoustic beams; Probes; Kidney; Imaging; Image segmentation; Visualization; Needle-image alignment; Percutaneous intervention; Ultrasound-guided intervention; Dual-segment array; PERCUTANEOUS NEPHROLITHOTOMY; VISUALIZATION; GUIDANCE; FREEHAND; BIOPSY; SYSTEM;
D O I
10.1109/TBME.2023.3260735
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Ultrasound (US) guided access for percutaneous nephrolithotomy (PCNL) is gaining popularity in the urology community as it reduces radiation risk. The most popular technique involves manual image-needle alignment. A misaligned needle however needs to be retracted and reinserted, resulting in a lengthened operation time and complications such as bleeding. These limitations can be mitigated through the co-registration between the US array and needle. The through-hole array concept provides the primary solution, including a hole at the center of the array. Because of the central opening, the image-needle alignment is achieved inherently. Previous literature has described applications that are limited to superficial and intravascular procedures, suggesting that developing a through-hole array for deeper target applications would be a new breakthrough. Objective. Here, we present a dual-segment array with a central opening. As the prototype development, two segments of 32-element arrays are combined with an open space of 10 mm in length in between them. Method. We conducted phantom and ex-vivo studies considering the target depth of the 80-100 mm range. The image quality and needle visibility are evaluated by comparing the signal-to-noise ratio (SNR), full width at half maximum (FWHM), and contrast-to-noise ratio (CNR) results measured with a no-hole linear array under equivalent conditions. An ex-vivo study is performed using porcine kidneys with ceramic balls embedded to evaluate the needle access accuracy. Results and conclusion.The mean needle access error of 20 trials is found to be 2.94$\pm$1.09 mm, suggesting its potential impact on realizing a simple and intuitive deep US image-guided access.
引用
收藏
页码:2645 / 2654
页数:10
相关论文
共 50 条
  • [1] Image-guided phased array system for ultrasound thermotherapy
    VanBaren, P
    Simon, C
    Seip, R
    Solf, T
    Cain, CA
    Ebbini, ES
    1996 IEEE ULTRASONICS SYMPOSIUM, PROCEEDINGS, VOLS 1 AND 2, 1996, : 1269 - 1272
  • [2] Mirror-Integrated Ultrasound Image-Guided Access
    Tang, Yichuan
    Abouaf, Isaac
    Malik, Aditya
    Gonzalez, Araceli B.
    Mishra, Arnav
    Tsumura, Ryosuke
    Kaminski, Jakub T.
    Sorokin, Igor
    Zhang, Haichong
    MEDICAL IMAGING 2022: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2022, 12034
  • [3] Conformal Ultrasound Transducer Array for Image-Guided Neural Therapy
    Pashaei, Vida
    Roman, Alex
    Mandal, Soumyajit
    2018 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS): ADVANCED SYSTEMS FOR ENHANCING HUMAN HEALTH, 2018, : 679 - 682
  • [4] A Dual-Mode 2D Matrix Array for Ultrasound Image-Guided Noninvasive Therapy
    Zhang, Zhiqiang
    Liu, Rong
    Li, Guofeng
    Su, Min
    Li, Fei
    Zheng, Hairong
    Qiu, Weibao
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2021, 68 (12) : 3482 - 3490
  • [5] Image-Guided Endobronchial Ultrasound
    Higgins, William E.
    Zang, Xiaonan
    Cheirsilp, Ronnarit
    Byrnes, Patrick
    Kuhlengel, Trevor
    Bascom, Rebecca
    Toth, Jennifer
    MEDICAL IMAGING 2016: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2016, 9786
  • [6] Partial Estimation of Needle Tip Orientation in Generalized Coordinates in Ultrasound Image-guided Needle Insertion
    Fallahi, Bita
    Rossa, Carlos
    Sloboda, Ronald
    Usmani, Nawaid
    Tavakoli, Mahdi
    2016 IEEE INTERNATIONAL CONFERENCE ON ADVANCED INTELLIGENT MECHATRONICS (AIM), 2016, : 1604 - 1609
  • [7] Magnetic resonance and ultrasound image-guided navigation system using a needle manipulator
    Yamada, Atsushi
    Tokuda, Junichi
    Naka, Shigeyuki
    Murakami, Koichiro
    Tani, Tohru
    Morikawa, Shigehiro
    MEDICAL PHYSICS, 2020, 47 (03) : 850 - 858
  • [8] Dual-mode ultrasound phased arrays for image-guided surgery
    Ebbini, Emad S.
    Yao, Hui
    Shrestha, Ajay
    ULTRASONIC IMAGING, 2006, 28 (02) : 65 - 82
  • [9] Image-Guided Refocusing of Dual-Mode Ultrasound Arrays (DMUAs)
    Ballard, John R.
    Casper, Andrew J.
    Ebbini, Ernad S.
    2008 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4 AND APPENDIX, 2008, : 1183 - 1186
  • [10] Dual Orientation 16-MHz Single-Element Ultrasound Needle Transducers for Image-Guided Neurosurgical Intervention
    Jiang, Yun
    Qiu, Zhen
    McPhillips, Rachael
    Meggs, Carl
    Mahboob, Syed Osama
    Wang, Han
    Duncan, Robyn
    Rodriguez-Sanmartin, Daniel
    Zhang, Ye
    Schiavone, Giuseppe
    Eisma, Roos
    Desmulliez, Marc P. Y.
    Eljamel, Sam
    Cochran, Sandy
    Button, Tim W.
    Demore, Christine E. M.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2016, 63 (02) : 233 - 244