Immediate and Follow-up Imaging Findings after Cone-Beam CT-guided Transbronchial Lung Cryobiopsy

被引:1
|
作者
Pogatchnik, Brian P. [1 ]
Swenson, Kai E. [3 ,4 ]
Duong, Duy Kevin [2 ]
Shaller, Brian [2 ]
Bedi, Harmeet [2 ]
Guo, H. Henry [1 ]
机构
[1] Stanford Univ, Dept Radiol, Sch Med, 300 Pasteur Dr,S072, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Med, Div Pulmonol Allergy & Crit Care Med, Sch Med, 300 Pasteur Dr,S072, Stanford, CA 94305 USA
[3] Beth Israel Deaconess Med Ctr, Div Pulm Crit Care & Sleep Med, Boston, MA USA
[4] Massachusetts Gen Hosp, Div Pulm & Crit Care Med, Boston, MA USA
来源
RADIOLOGY-CARDIOTHORACIC IMAGING | 2023年 / 5卷 / 02期
关键词
Biopsy/Needle Aspiration; CT; Lungs; Lung Biopsy; Interventional Bronchoscopy; DISEASE;
D O I
10.1148/ryct.220149
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate findings after transbronchial lung cryobiopsy (TBLC) using intraprocedural cone-beam CT (CBCT) and follow-up chest CT examinations. Materials and Methods: A single-center, prospective cohort study was performed with 14 participants (mean age, 65 years 13 [SD]; eight male participants) undergoing CBCT-guided TBLC between August 2020 and February 2021 who underwent follow-up chest CT imaging. Intraprocedural CBCT and follow-up chest CT images were interpreted for changes compared with baseline CT images. Statistical analyses were performed using independent samples t test and analysis of variance. Results: A total of 62 biopsies were performed, with 48 in the field of view of CBCT immediately after biopsy. All 48 biopsy sites had evidence of postprocedural hemorrhage, and 17 (35%) had pneumatoceles at the biopsy site. Follow-up CT images showed resolution of these findings. Solid nodules developed at 18 of the 62 (29%) biopsy sites. Conclusion: Postbiopsy hemorrhage and pneumatoceles on intraprocedural CBCT images (which were clinically occult and resolved spontaneously) and new solid nodules on follow-up chest CT images were commonly observed after TBLC. These findings may help alleviate unnecessary follow-up imaging and tissue sampling.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Assessment of residual error for online cone-beam CT-guided treatment of prostate cancer patients
    Létourneau, D
    Martinez, AA
    Lockman, D
    Yan, D
    Vargas, C
    Ivaldi, G
    Wong, J
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (04): : 1239 - 1246
  • [42] Chinese expert consensus on cone-beam CT-guided diagnosis, localization and treatment for pulmonary nodules
    Xu, Dongyang
    Xie, Fangfang
    Zhang, Jisong
    Chen, Hong
    Chen, Zhongbo
    Guan, Zhenbiao
    Hou, Gang
    Ji, Cheng
    Li, Haitao
    Li, Manxiang
    Li, Wei
    Li, Xuan
    Li, Yishi
    Lian, Hairong
    Liao, Jiangrong
    Liu, Dan
    Luo, Zhuang
    Ouyang, Haifeng
    Shen, Yongchun
    Shi, Yiwei
    Tang, Chunli
    Wan, Nansheng
    Wang, Tao
    Wang, Hong
    Wang, Huaqi
    Wang, Juan
    Wu, Xuemei
    Xia, Yang
    Xiao, Kui
    Xu, Wujian
    Xu, Fei
    Yang, Huizhen
    Yang, Junyong
    Ye, Taosheng
    Ye, Xianwei
    Yu, Pengfei
    Zhang, Nan
    Zhang, Peng
    Zhang, Quncheng
    Zhao, Qi
    Zheng, Xiaoxuan
    Zou, Jun
    Chen, Enguo
    Sun, Jiayuan
    THORACIC CANCER, 2024, 15 (07) : 582 - 597
  • [43] The value of Cone-Beam CT-guided radiofrequency ablation in the treatment of pulmonary malignancies (≤3 cm)
    Xiang, Zi-jun
    Wang, Yi
    Du, En-fu
    Xu, Lin
    Jiang, Bin
    Li, Huili
    Wang, Yun
    Cui, Ning
    BIOSCIENCE REPORTS, 2019, 39
  • [44] Diagnostic value of follow-up transbronchial lung biopsy after lung rejection
    Aboyoun, CL
    Tamm, M
    Chhajed, PN
    Hopkins, P
    Malouf, MA
    Rainer, S
    Glanville, AR
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2001, 164 (03) : 460 - 463
  • [45] Planning CT-guided robust and fast cone-beam CT scatter correction using a local filtration technique
    Cui, Hehe
    Jiang, Xiao
    Fang, Chengyijue
    Zhu, Lei
    Yang, Yidong
    MEDICAL PHYSICS, 2021, 48 (11) : 6832 - 6843
  • [46] Multidetector CT fluoroscopy and cone-beam CT-guided percutaneous transthoracic biopsy: comparison based on patient doses
    Strocchi, S.
    Colli, V.
    Conte, L.
    RADIATION PROTECTION DOSIMETRY, 2012, 151 (01) : 162 - 165
  • [47] C-Arm Cone-Beam CT-Guided Percutaneous Transthoracic Lung Biopsy: Usefulness in Evaluation of Small Pulmonary Nodules
    Hwang, Hye Sun
    Chung, Myung Jin
    Lee, Ju Won
    Shin, Sung Wook
    Lee, Kyung Soo
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (06) : W400 - W407
  • [48] Cone-beam CT-guided radiotherapy in the management of lung cancer: Diagnostic and therapeutic value; [Cone-beam-CT-basierte Strahlentherapie bei lungenkrebs: Diagnostischer und therapeutischer Wert]
    Elsayad K.
    Kriz J.
    Reinartz G.
    Scobioala S.
    Ernst I.
    Haverkamp U.
    Eich H.T.
    Strahlentherapie und Onkologie, 2016, 192 (2) : 83 - 91
  • [49] Imaging-guided percutaneous transthoracic needle biopsy of nodules in the lung base: fluoroscopy CT versus cone-beam CT
    Ren, Q.
    Zhou, Y.
    Yan, M.
    Zheng, C.
    Zhou, G.
    Xia, X.
    CLINICAL RADIOLOGY, 2022, 77 (05) : E394 - E399
  • [50] Safety and diagnostic efficacy of cone beam computed tomography-guided transbronchial cryobiopsy for interstitial lung disease: a cohort study
    Zhou, Guowu
    Ren, Yanhong
    Li, Jun
    Yang, Ting
    Su, Nan
    Zhao, Ling
    Wang, Dan
    Li, Ying
    Tian, Zheng
    Liu, Ruihong
    Dai, Huaping
    Wang, Chen
    EUROPEAN RESPIRATORY JOURNAL, 2020, 56 (02)