Immediate and Follow-up Imaging Findings after Cone-Beam CT-guided Transbronchial Lung Cryobiopsy

被引:1
|
作者
Pogatchnik, Brian P. [1 ]
Swenson, Kai E. [3 ,4 ]
Duong, Duy Kevin [2 ]
Shaller, Brian [2 ]
Bedi, Harmeet [2 ]
Guo, H. Henry [1 ]
机构
[1] Stanford Univ, Dept Radiol, Sch Med, 300 Pasteur Dr,S072, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Med, Div Pulmonol Allergy & Crit Care Med, Sch Med, 300 Pasteur Dr,S072, Stanford, CA 94305 USA
[3] Beth Israel Deaconess Med Ctr, Div Pulm Crit Care & Sleep Med, Boston, MA USA
[4] Massachusetts Gen Hosp, Div Pulm & Crit Care Med, Boston, MA USA
来源
RADIOLOGY-CARDIOTHORACIC IMAGING | 2023年 / 5卷 / 02期
关键词
Biopsy/Needle Aspiration; CT; Lungs; Lung Biopsy; Interventional Bronchoscopy; DISEASE;
D O I
10.1148/ryct.220149
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate findings after transbronchial lung cryobiopsy (TBLC) using intraprocedural cone-beam CT (CBCT) and follow-up chest CT examinations. Materials and Methods: A single-center, prospective cohort study was performed with 14 participants (mean age, 65 years 13 [SD]; eight male participants) undergoing CBCT-guided TBLC between August 2020 and February 2021 who underwent follow-up chest CT imaging. Intraprocedural CBCT and follow-up chest CT images were interpreted for changes compared with baseline CT images. Statistical analyses were performed using independent samples t test and analysis of variance. Results: A total of 62 biopsies were performed, with 48 in the field of view of CBCT immediately after biopsy. All 48 biopsy sites had evidence of postprocedural hemorrhage, and 17 (35%) had pneumatoceles at the biopsy site. Follow-up CT images showed resolution of these findings. Solid nodules developed at 18 of the 62 (29%) biopsy sites. Conclusion: Postbiopsy hemorrhage and pneumatoceles on intraprocedural CBCT images (which were clinically occult and resolved spontaneously) and new solid nodules on follow-up chest CT images were commonly observed after TBLC. These findings may help alleviate unnecessary follow-up imaging and tissue sampling.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Investigation of C-arm cone-beam CT-guided surgery of the frontal recess
    Rafferty, MA
    Siewerdsen, JH
    Chan, Y
    Moseley, DJ
    Daly, MJ
    Jaffray, DA
    Irish, JC
    LARYNGOSCOPE, 2005, 115 (12): : 2138 - 2143
  • [32] Dosimetric impact of online KV cone-beam CT-guided radiotherapy in prostate cancer
    Chilles, A.
    Ginestet, C.
    Ayadi, M.
    Pommier, P.
    Carrie, C.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S112 - S112
  • [33] Erratum to: TREK: an integrated system architecture for intraoperative cone-beam CT-guided surgery
    A. Uneri
    S. Schafer
    D. J. Mirota
    S. Nithiananthan
    Y. Otake
    R. H. Taylor
    G. L. Gallia
    A. J. Khanna
    S. Lee
    D. D. Reh
    J. H. Siewerdsen
    International Journal of Computer Assisted Radiology and Surgery, 2012, 7 : 175 - 175
  • [34] Efficacy and safety of intraoperative cone-beam CT-guided localization of small pulmonary nodules
    Kaiho, Taisuke
    Suzuki, Hidemi
    Hata, Atsushi
    Ito, Takamasa
    Tanaka, Kazuhisa
    Sakairi, Yuichi
    Kato, Hideyuki
    Shiko, Yuki
    Kawasaki, Yohei
    Yoshino, Ichiro
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2022, 35 (04)
  • [35] Cone-beam computed tomography-guided transbronchial lung biopsies: Leading the way to precision
    Gonuguntla, Hari Kishan
    Vidyasagar, Preeti
    Mrigpuri, Parul
    LUNG INDIA, 2024, 41 (06) : 480 - 482
  • [36] Comparison of Postprostatic Artery Embolization Cone-Beam CT and Estimated Radiopaque Particle Distribution on Follow-up Imaging: A Case Report
    Brown, Benjamin
    Brader, Rachel
    Bagla, Sandeep
    Isaacson, Ari
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2020, 31 (05) : 864 - 867
  • [37] The dosimetric impact of translation-only setup correction in cone-beam CT-guided stereotactic radiotherapy for lung tumors
    Suen, A. W.
    Chao, K.
    Grills, I. S.
    Yan, D.
    Kestin, L. L.
    Martinez, A. A.
    Hugo, G.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S633 - S634
  • [38] RADIATION DOSE ASSOCIATED WITH CT-GUIDED PERCUTANEOUS RENAL MASS ABLATION AND IMAGING FOLLOW-UP
    Hoch, Sarah
    Durack, Jeremy
    Sorensen, Mathew
    Gould, Robert
    Stoller, Marshall
    JOURNAL OF UROLOGY, 2011, 185 (04): : E889 - E889
  • [39] Fluoroscopy and Cone-Beam CT-guided Fixation by Internal Cemented Screw for Pathologic Pelvic Fractures
    Roux, Charles
    Tselikas, Lambros
    Yevich, Steven
    Solha, Raphael Sandes
    Hakime, Antoine
    Teriitehau, Christophe
    Gravel, Guillaume
    de Baere, Thierry
    Deschamps, Frederic
    RADIOLOGY, 2019, 290 (02) : 418 - 425
  • [40] Deformable image registration with local rigidity constraints for cone-beam CT-guided spine surgery
    Reaungamornrat, S.
    Wang, A. S.
    Uneri, A.
    Otake, Y.
    Khanna, A. J.
    Siewerdsen, J. H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (14): : 3761 - 3787