Solid-Phase Extraction (SPE) Technique to Quantify Cefdinir in Human Plasma Using Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS)

被引:3
|
作者
Alam, Md Tauquir [1 ]
Mujtaba, Md Ali [2 ]
Hussain, Afzal [3 ]
Ali, Abuzer [4 ]
Imran, Mohd [1 ]
Abul Barkat, Md [1 ,5 ]
Abdel-Gawad, Sherif A. [6 ,7 ]
机构
[1] Northern Border Univ, Fac Pharm, Dept Pharmaceut Chem, Rafha 91911, Saudi Arabia
[2] Northern Border Univ, Fac Pharm, Dept Pharmaceut, Rafha 91911, Saudi Arabia
[3] King Saud Univ, Coll Pharm, Dept Pharmaceut, Riyadh 11451, Saudi Arabia
[4] Taif Univ, Coll Pharm, Dept Pharmacognosy, POB 11099, Taif 21944, Saudi Arabia
[5] Univ Hafr Al Batin, Coll Pharm, Dept Pharmaceut, Al Jamiah 39524, Hafr Al Batin, Saudi Arabia
[6] Prince Sattam Bin Abdulaziz Univ, Coll Pharm, Pharmaceut Chem Dept, Al Kharj 11942, Saudi Arabia
[7] Cairo Univ, Fac Pharm, Analyt & Chem Dept, ET-11562 Cairo, Egypt
关键词
BIOANALYTICAL METHOD VALIDATION; ELECTROSPRAY-IONIZATION; URINE; HPLC;
D O I
10.1093/chromsci/bmac054
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A biosensitive analysis method development and validation was performed for accurate and rapid quantification of cefdinir (CDR) in human plasma by a liquid chromatography-tandem mass spectrometry technique coupled with electrospray ionization. Analysis was carried out using a C-18 column with a flow rate of 1.0 mL/min and operating temperature of 30.0 +/- 1 degrees C. The drug was eluted by optimizing the m/z ratios of 396.20 -> 227.20 and 428.17 -> 241.10, for cefdinir and IS (internal standard), respectively. The intraday precision (%CV) for Cefdinir ranged from 2.8% and 6.7% as lower limit of quantification of quality control (LLOQ QC) and higher level of quantification of quality control (HQC QC), respectively, whereas these value were found to be as 3.0% and 5.6% for LLOQ and HQC, respectively after interday precision. Moreover, accuracy ranged from 107.70% (HQC QC) to 95.5% (LLOQ QC). The extraction mean recovery was found to be 83.91 +/- 6.0% for cefdinir and 76.7 +/- 6.23% for IS. The drug was stable throughout the analysis period. It was possible to analyze several plasma samples every day since each sample took <2.5 min to run. The method demonstrated successful quantification of CDR in human plasma, followed by pharmacokinetic profiles that were simple, accurate, sensitive and cost-effective.
引用
收藏
页码:366 / 374
页数:9
相关论文
共 50 条
  • [41] Method for the determination of perfluorinated compounds (PFCs) in water by solid-phase extraction and liquid chromatography/tandem mass spectrometry (LC/MS/MS)
    Wolf, Susan T.
    Reagen, William K.
    ANALYTICAL METHODS, 2011, 3 (07) : 1485 - 1493
  • [42] Liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the analysis of free metanephrine and free normetanephrine in human
    Lagerstedt, SA
    O'Kane, DJ
    Singh, RJ
    CLINICAL CHEMISTRY, 2003, 49 (06) : A43 - A43
  • [43] A Double-Barrel Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) System to Quantify 96 Interactomes per Day
    Hosp, Fabian
    Scheltema, Richard A.
    Eberl, H. Christian
    Kulak, Nils A.
    Keilhauer, Eva C.
    Mayr, Korbinian
    Mann, Matthias
    MOLECULAR & CELLULAR PROTEOMICS, 2015, 14 (07) : 2030 - 2041
  • [44] Determination of more than 500 Pesticide Residues in Hen Eggs by Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) and Gas Chromatography-Tandem Mass Spectrometry (GC/MS/MS)
    Golge, Ozgur
    Liman, Turan
    Kabak, Bulent
    FOOD SCIENCE OF ANIMAL RESOURCES, 2021, 41 (05) : 816 - 825
  • [45] Rapid and simple method for determination of cephradine in human plasma using liquid chromatography-tandem mass spectrometry (LC-MS/MS): Application to the bioequivalence study
    Choi, Sang-Jun
    Ryu, Ju-Hee
    Lee, Heon-Woo
    Lee, Myung-Jae
    Seo, Ji-Hyung
    Tak, Seong-Kun
    Lee, Kyung-Tae
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (31): : 4059 - 4064
  • [46] Determination of pharmaceuticals in sewage sludge by pressurized liquid extraction (PLE) coupled to liquid chromatography-tandem mass spectrometry (LC-MS/MS)
    Radjenovic, J.
    Jelic, A.
    Petrovic, M.
    Barcelo, D.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 393 (6-7) : 1685 - 1695
  • [47] Determination of pharmaceuticals in sewage sludge by pressurized liquid extraction (PLE) coupled to liquid chromatography-tandem mass spectrometry (LC-MS/MS)
    J. Radjenović
    A. Jelić
    M. Petrović
    D. Barceló
    Analytical and Bioanalytical Chemistry, 2009, 393 : 1685 - 1695
  • [48] Biomonitoring of azole fungicides in free-living blackbird plasma using on-line solid-phase extraction coupled to liquid chromatography-tandem mass spectrometry (SPE HPLC-MS/MS)
    Prouteau, Louise
    Devier, Marie-Helene
    Angelier, Frederic
    Chastel, Olivier
    Brischoux, Francois
    Pardon, Patrick
    Le Menach, Karyn
    Budzinski, Helene
    JOURNAL OF CHROMATOGRAPHY A, 2025, 1748
  • [49] The determination of capreomycin in human plasma by LC-MS/MS using ion-pairing chromatography and solid-phase extraction
    Thuboy, Blessings
    Kellermann, Tracy
    Castel, Sandra
    Norman, Jennifer
    Joubert, Anton
    Garcia-Prats, Anthony J.
    Hesseling, Anneke C.
    Wiesner, Lubbe
    BIOMEDICAL CHROMATOGRAPHY, 2018, 32 (09)
  • [50] Quantification of Ptaquiloside and Pterosin B in Soil and Groundwater Using Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS)
    Jensen, Pia H.
    Jacobsen, Ole S.
    Hansen, Hans Christian B.
    Juhler, Rene K.
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2008, 56 (21) : 9848 - 9854