Solid-Phase Extraction (SPE) Technique to Quantify Cefdinir in Human Plasma Using Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS)

被引:3
|
作者
Alam, Md Tauquir [1 ]
Mujtaba, Md Ali [2 ]
Hussain, Afzal [3 ]
Ali, Abuzer [4 ]
Imran, Mohd [1 ]
Abul Barkat, Md [1 ,5 ]
Abdel-Gawad, Sherif A. [6 ,7 ]
机构
[1] Northern Border Univ, Fac Pharm, Dept Pharmaceut Chem, Rafha 91911, Saudi Arabia
[2] Northern Border Univ, Fac Pharm, Dept Pharmaceut, Rafha 91911, Saudi Arabia
[3] King Saud Univ, Coll Pharm, Dept Pharmaceut, Riyadh 11451, Saudi Arabia
[4] Taif Univ, Coll Pharm, Dept Pharmacognosy, POB 11099, Taif 21944, Saudi Arabia
[5] Univ Hafr Al Batin, Coll Pharm, Dept Pharmaceut, Al Jamiah 39524, Hafr Al Batin, Saudi Arabia
[6] Prince Sattam Bin Abdulaziz Univ, Coll Pharm, Pharmaceut Chem Dept, Al Kharj 11942, Saudi Arabia
[7] Cairo Univ, Fac Pharm, Analyt & Chem Dept, ET-11562 Cairo, Egypt
关键词
BIOANALYTICAL METHOD VALIDATION; ELECTROSPRAY-IONIZATION; URINE; HPLC;
D O I
10.1093/chromsci/bmac054
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A biosensitive analysis method development and validation was performed for accurate and rapid quantification of cefdinir (CDR) in human plasma by a liquid chromatography-tandem mass spectrometry technique coupled with electrospray ionization. Analysis was carried out using a C-18 column with a flow rate of 1.0 mL/min and operating temperature of 30.0 +/- 1 degrees C. The drug was eluted by optimizing the m/z ratios of 396.20 -> 227.20 and 428.17 -> 241.10, for cefdinir and IS (internal standard), respectively. The intraday precision (%CV) for Cefdinir ranged from 2.8% and 6.7% as lower limit of quantification of quality control (LLOQ QC) and higher level of quantification of quality control (HQC QC), respectively, whereas these value were found to be as 3.0% and 5.6% for LLOQ and HQC, respectively after interday precision. Moreover, accuracy ranged from 107.70% (HQC QC) to 95.5% (LLOQ QC). The extraction mean recovery was found to be 83.91 +/- 6.0% for cefdinir and 76.7 +/- 6.23% for IS. The drug was stable throughout the analysis period. It was possible to analyze several plasma samples every day since each sample took <2.5 min to run. The method demonstrated successful quantification of CDR in human plasma, followed by pharmacokinetic profiles that were simple, accurate, sensitive and cost-effective.
引用
收藏
页码:366 / 374
页数:9
相关论文
共 50 条
  • [31] Determination of glabridin in human plasma by solid-phase extraction and LC-MS/MS
    Aoki, F
    Nakagawa, K
    Tanaka, A
    Matsuzaki, K
    Arai, N
    Mae, T
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 828 (1-2): : 70 - 74
  • [32] Quantification of Amino Acids in Plasma by High-Performance Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS)
    Panaskar, Shrimant N.
    Singh, Susheel K.
    CHROMATOGRAPHIA, 2023, 86 (07) : 567 - 572
  • [33] Determination of Pharmaceutical Residues in Fish Bile by Solid-Phase Microextraction Couple with Liquid Chromatography-Tandem Mass Spectrometry (LC/MS/MS)
    Togunde, Oluranti P.
    Oakes, Ken D.
    Servos, Mark R.
    Pawliszyn, Janusz
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2012, 46 (10) : 5302 - 5309
  • [34] Analysis of aldosterone/plasma renin activity in a single method by liquid chromatography-tandem mass spectrometry (LC-MS/MS)
    Orton, Dennis
    Buse, Joshua
    Sadrzadeh, S. M. Hossein
    Chin, Alex
    CLINICAL BIOCHEMISTRY, 2015, 48 (15) : 1006 - 1006
  • [35] Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) Method for the Quantitation of Sulforaphane (SFN) in Human Plasma and Insights into Decomposition Pathways
    Grady, Rachel
    Traustadottir, Tinna
    Lagalante, Anthony
    Eggler, Aimee
    FREE RADICAL BIOLOGY AND MEDICINE, 2022, 180 : 61 - 61
  • [36] LIQUID CHROMATOGRAPHY-ELECTROSPRAY TANDEM MASS SPECTROMETRY (LC-MS/MS) DETERMINATION OF LANSOPRAZOLE IN HUMAN PLASMA
    Ganesh, M.
    BhagiyaLakshmi, M.
    Hemalatha, P.
    Patil, Rahul
    Sakthimanigandan, K.
    Jang, Hyun Tae
    Rajasekar, K.
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2011, 34 (02) : 129 - 142
  • [37] Identification and quantification of the atypical metabolite ornithine-lactam in human plasma by liquid chromatography-tandem mass spectrometry (LC-MS/MS)
    Martens-Lobenhoffer, Jens
    Becker, Achim
    Freude, Horst
    Bode-Boeger, Stefanie M.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (23): : 2284 - 2289
  • [38] Detection of cannabinoids in dried blood spots by liquid chromatography-tandem mass spectrometry (LC-MS/MS)
    Paul, Heather
    Awad, Hanan
    Sadrzadeh, S. M. Hossein
    Boyd, Jessica
    CLINICAL BIOCHEMISTRY, 2019, 74 : 93 - 93
  • [39] Matrix effect on the analysis of amphenicols in fish by liquid chromatography-tandem mass spectrometry (LC-MS/MS)
    Guidi, L. R.
    Tette, P. A. S.
    Evangelista, W. P.
    Fernandes, C.
    Gloria, M. B. A.
    VII BRAZILIAN CONGRESS ON METROLOGY (METROLOGIA 2013), 2015, 575
  • [40] Quantification of isoflavones in coffee by using solid phase extraction (SPE) and high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS)
    Caprioli, Giovanni
    Navarini, Luciano
    Cortese, Manuela
    Ricciutelli, Massimo
    Torregiani, Elisabetta
    Vittori, Sauro
    Sagratini, Gianni
    JOURNAL OF MASS SPECTROMETRY, 2016, 51 (09): : 698 - 703