Towards biomechanics-based pre-procedural planning for thoracic endovascular aortic repair of aortic dissection

被引:2
|
作者
Kan, Xiaoxin [1 ,2 ]
Ma, Tao [3 ,4 ]
Jiang, Xiaolang [3 ,4 ]
Holzapfel, Gerhard A. [5 ,6 ]
Dong, Zhihui [1 ,3 ,4 ]
Xu, Xiao Yun [2 ]
机构
[1] Fudan Univ, Jinshan Hosp, Ctr Vasc Surg & Wound Care, Shanghai, Peoples R China
[2] Imperial Coll London, Dept Chem Engn, London, England
[3] Fudan Univ, Zhongshan Hosp, Dept Vasc Surg, Shanghai, Peoples R China
[4] Fudan Univ, Zhongshan Hosp, Inst Vasc Surg, Shanghai, Peoples R China
[5] Graz Univ Technol, Inst Biomech, Graz, Austria
[6] Norwegian Univ Sci & Technol NTNU, Dept Struct Engn, Trondheim, Norway
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
Finite element analysis; Tevar; Type B aortic dissection; Stent-graft; Virtual stent-graft deployment; STENT-GRAFT DEPLOYMENT; SIMULATIONS; MECHANICS; ENTRY;
D O I
10.1016/j.cmpb.2023.107994
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Background and objective: Although thoracic aortic endovascular repair (TEVAR) has shown promising outcomes in the treatment of patients with complicated type B aortic dissection, complications still occur after TEVAR that can lead to catastrophic events. Biomechanical interactions between the stent-graft (SG) and the local aortic tissue play a critical role in determining the outcome of TEVAR. Different SG design may cause different biomechanical responses in the treated aorta, but such information is not known at the time of pre-procedural planning. By developing patient-specific virtual stent-graft deployment tools, it is possible to analyse and compare the biomechanical impact of different SGs on the local aorta for individual patients. Methods: A finite element based virtual SG deployment model was employed in this study. Computational simulations were performed on a patient-specific model of type B aortic dissection, accounting for details of the SG design and the hyperelastic behaviour of the aortic wall. Based on the geometry reconstructed from the preTEVAR CTA scan, the patient-specific aortic dissection model was created and pre-stressed. Parametric models of three different SG products (SG1, SG2 and SG3) were built with two different lengths for each design. The SG models incorporated different stent and graft materials, stent strut patterns, and assembly approaches. Using our validated SG deployment simulation framework, virtual trials were performed on the patient-specific aortic dissection model using different SG products and varying SG lengths. Conclusion: Simulation results for different SG products suggest that SG3 with a longer length (SG3-long) would be the most appropriate device for the individual patient. Compared to SG1-short (the SG deployed in the patient), SG3-long followed the true lumen tortuosity closely, resulted in a more uniform true lumen expansion and a significant reduction in peak stress in the distal landing zone. These simulation results are promising and demonstrate the feasibility of using the virtual SG deployment model to assist clinicians in pre-procedural planning.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Thoracic Endovascular Aortic Repair in Acute and Chronic Type B Aortic Dissection
    Trimarchi, Santi
    Eagle, Kim A.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (02) : 192 - 194
  • [32] Retrograde type A dissection after thoracic endovascular aortic repair for type B aortic dissection
    Yammine, Halim
    Briggs, Charles S.
    Stanley, Gregory A.
    Ballast, Jocelyn K.
    Anderson, William E.
    Nussbaum, Tzvi
    Madjarov, Jeko
    Frederick, John R.
    Arko, Frank R., III
    JOURNAL OF VASCULAR SURGERY, 2019, 69 (01) : 24 - 32
  • [33] Retrograde Type A Aortic Dissection after Thoracic Endovascular Aortic Repair for Tune B Dissection
    Hayakawa, Masato
    Nagano, Takaaki
    Nishijima, Isao
    Shinzato, Kento
    Ikemura, Ryo
    Miyagi, Kazufumi
    Iha, Kiyoshi
    Senaha, Shigenobu
    Shimoji, Mitsuyoshi
    Akasaki, Mitsuru
    HEART SURGERY FORUM, 2020, 23 (04): : E524 - E526
  • [34] Predictors for thoracic aortic growth in patients with type B aortic dissection after thoracic endovascular aortic repair
    Chen, Yonghui
    Ren, Jianli
    Liu, Zongwei
    Cui, Dongsheng
    Wang, Shuaishuai
    Bi, Jiaxue
    Dai, Xiangchen
    VASCULAR, 2024,
  • [35] Retrograde Type A Dissection After Thoracic Endovascular Aortic Repair for Type B Aortic Dissection
    Yammine, Halim
    Briggs, Charles S.
    Stanley, Gregory A.
    Ballast, Jocelyn K.
    Anderson, William E.
    Nussbaum, Tzvi
    Frederick, John R.
    Arko, Frank R., III
    JOURNAL OF VASCULAR SURGERY, 2018, 67 (01) : E9 - E9
  • [36] Aortic Morphologic Findings After Thoracic Endovascular Aortic Repair for Type B Aortic Dissection
    Sigman, Michael M.
    Palmer, Owen P.
    Ham, Sung W.
    Cunningham, Mark
    Weaver, Fred A.
    JAMA SURGERY, 2014, 149 (09) : 977 - 983
  • [37] Aortic Arch Debranching and Thoracic Endovascular Aortic Repair (TEVAR) for Type B Aortic Dissection
    Bashir, Mohamad
    Jubouri, Matti
    Surkhi, Abdelaziz O.
    Sadeghipour, Parham
    Pouraliakbar, Hamidreza
    Rabiee, Parham
    Jolfayi, Amir Ghaffari
    Mohebbi, Bahram
    Moosavi, Jamal
    Babaei, Mohammadreza
    Afrooghe, Arya
    Ghoorchian, Ehsan
    Awad, Wael I.
    Velayudhan, Bashi
    Mohammed, Idhrees
    Bailey, Damian M.
    Williams, Ian M.
    ANNALS OF VASCULAR SURGERY, 2024, 99 : 320 - 331
  • [38] Aortic rupture of acute aortic dissection type treated with thoracic endovascular aortic repair (TEVAR)
    Pompa, V.
    Papi, P.
    Coletti, M.
    Bresadola, L.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2016, 20 (18) : 3743 - 3747
  • [39] Thoracic Endovascular Aortic Repair for Descending Thoracic Aortic Enlargement Following Repair With the Ascyrus Medical Dissection Stent
    EL-Andari, Ryaan
    Bozso, Sabin J.
    O'Brien, Devin
    Chung, Jennifer
    Ouzounian, Maral
    Moon, Michael C.
    CANADIAN JOURNAL OF CARDIOLOGY, 2023, 39 (11) : 1698 - 1700
  • [40] Computational tools for thoracic endovascular aortic repair planning
    Auricchio, Ferdinando
    Conti, Michele
    Romarowski, Rodrigo M.
    De Beaufort, Hector W.
    Grassi, Viviana
    Trimarchi, Santi
    ITALIAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2019, 26 (01): : 51 - 58