Monte Carlo study of X-ray grazing incidence microscopy using Geant4

被引:0
|
作者
Li, Wenjie [1 ,2 ]
Xu, Jie [1 ,2 ]
Yang, Cheng [1 ,2 ]
Li, Mingtao [1 ,2 ]
Wang, Xin [1 ,2 ]
Zhang, Xing [3 ]
Mu, Baozhong [1 ,2 ]
机构
[1] Tongji Univ, Key Lab Adv Microstruct Mat, Minist Educ, Shanghai 200092, Peoples R China
[2] Tongji Univ, Sch Phys Sci & Engn, Shanghai 200092, Peoples R China
[3] China Acad Engn Phys, Res Ctr Laser Fus, Mianyang 621900, Peoples R China
基金
中国国家自然科学基金;
关键词
KIRKPATRICK-BAEZ MICROSCOPE; TOTAL-REFLECTION; ANGLE;
D O I
10.1364/OE.497436
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
X-ray grazing incidence microscopy has extensive applications in the fields of laser inertial confinement fusion and synchrotron radiation. Monte Carlo methods can be used to determine the optical performance of X-ray grazing incidence microscopes and predict the experimental results, which is of great significance for studying physical experiments and diagnostics. In this paper, we proposed a Monte Carlo method based on Geant4 for studying X-ray grazing incidence microscopy. We introduced the G4MultilayerReflection class to describe the physical processes of X-ray multilayer mirrors. We designed a dual-energy Kirkpatrick-Baez microscope that can operate at 6.4 and 9.67 keV simultaneously. Monte Carlo simulations of the spatial resolution and throughput efficiency of the microscope were performed using Geant4, which was assembled and characterized. The spatial resolution results obtained by the Geant4 laboratory simulations, the theoretical model, and the experiments were in good agreement. Additionally, we conducted throughput efficiency calibration experiments for the 6.4 keV imaging channel. The difference between the experimental and Geant4-simulated throughput efficiency was evaluated and resulted in root mean square error values of 8.7% and 9.5% along the Y-and Z-axes, respectively.(c) 2023 Optica Publishing Group under the terms of the Optica Open Access Publishing Agreement
引用
收藏
页码:35453 / 35470
页数:18
相关论文
共 50 条
  • [41] A GEANT4 based simulation for pixelated X-ray hybrid detectors
    Marinho, F.
    Akiba, K.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 772 : 50 - 51
  • [42] Fast simulation of x-ray transition radiation in the GEANT4 toolkit
    Grichine, VM
    ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, 2001, : 117 - 122
  • [43] Geant4 simulations of soft proton scattering in X-ray optics
    Fioretti, Valentina
    Mineo, Teresa
    Bulgarelli, Andrea
    Dondero, Paolo
    Ivanchenko, Vladimir
    Lei, Fan
    Lotti, Simone
    Macculi, Claudio
    Mantero, Alfonso
    EXPERIMENTAL ASTRONOMY, 2017, 44 (03) : 413 - 435
  • [44] Simulation of ultrasoft X-rays induced DNA damage using the Geant4 Monte Carlo toolkit
    Tajik, Marjan
    Rozatian, Amir S. H.
    Semsarha, Farid
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2015, 342 : 258 - 265
  • [45] GEANT4 simulation and spectrum restoration of a pixelated X-ray detector
    Tykhonov, Andrii
    Winkler, Alexander
    Smoliar, Volodymyr
    JOURNAL OF INSTRUMENTATION, 2023, 18 (04)
  • [46] Geant4 simulation of the response of phosphor screens for X-ray imaging
    Pistrui-Maximean, S. A.
    Freud, N.
    Letang, J. M.
    Koch, A.
    Munier, B.
    Walenta, A. H.
    Montarou, G.
    Babot, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 563 (01): : 196 - 199
  • [47] Geant4 portlet: Monte-Carlo simulation with Geant4 on bwGRiD over a browser-based interface
    Zyl, A.
    Hesser, J.
    Mosch, C.
    Alnewaini, Z.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2012, 188 : 168 - 169
  • [48] Comparing the output of measured and GEANT4 simulated X-ray tubes
    Kirkpatrick, Molly
    Hood, Sean
    Guatelli, Susanna
    Van Haarlem, Yves
    RADIATION PHYSICS AND CHEMISTRY, 2024, 220
  • [49] GEANT4 simulation of X-ray transition radiation at small angles
    Grichine, V. M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1027
  • [50] Geant4/GATE Monte Carlo Code for Internal Dosimetry Using Voxelized Phantom
    S. Kaddouch
    N. El Khayati
    Moscow University Physics Bulletin, 2017, 72 : 658 - 662