Monte Carlo study of X-ray grazing incidence microscopy using Geant4

被引:0
|
作者
Li, Wenjie [1 ,2 ]
Xu, Jie [1 ,2 ]
Yang, Cheng [1 ,2 ]
Li, Mingtao [1 ,2 ]
Wang, Xin [1 ,2 ]
Zhang, Xing [3 ]
Mu, Baozhong [1 ,2 ]
机构
[1] Tongji Univ, Key Lab Adv Microstruct Mat, Minist Educ, Shanghai 200092, Peoples R China
[2] Tongji Univ, Sch Phys Sci & Engn, Shanghai 200092, Peoples R China
[3] China Acad Engn Phys, Res Ctr Laser Fus, Mianyang 621900, Peoples R China
基金
中国国家自然科学基金;
关键词
KIRKPATRICK-BAEZ MICROSCOPE; TOTAL-REFLECTION; ANGLE;
D O I
10.1364/OE.497436
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
X-ray grazing incidence microscopy has extensive applications in the fields of laser inertial confinement fusion and synchrotron radiation. Monte Carlo methods can be used to determine the optical performance of X-ray grazing incidence microscopes and predict the experimental results, which is of great significance for studying physical experiments and diagnostics. In this paper, we proposed a Monte Carlo method based on Geant4 for studying X-ray grazing incidence microscopy. We introduced the G4MultilayerReflection class to describe the physical processes of X-ray multilayer mirrors. We designed a dual-energy Kirkpatrick-Baez microscope that can operate at 6.4 and 9.67 keV simultaneously. Monte Carlo simulations of the spatial resolution and throughput efficiency of the microscope were performed using Geant4, which was assembled and characterized. The spatial resolution results obtained by the Geant4 laboratory simulations, the theoretical model, and the experiments were in good agreement. Additionally, we conducted throughput efficiency calibration experiments for the 6.4 keV imaging channel. The difference between the experimental and Geant4-simulated throughput efficiency was evaluated and resulted in root mean square error values of 8.7% and 9.5% along the Y-and Z-axes, respectively.(c) 2023 Optica Publishing Group under the terms of the Optica Open Access Publishing Agreement
引用
收藏
页码:35453 / 35470
页数:18
相关论文
共 50 条
  • [31] Monte Carlo study of a double-scattering Compton camera with GEANT4
    Seo, Hee
    An, So Hyun
    Kim, Jong Kyung
    Kim, Chan Hyeong
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 314 - 317
  • [32] Calculation of surface spectral irradiance using the Geant4 Monte Carlo toolkit
    Boudjella, Manal Yasmine
    Belbachir, Ahmed Hafid
    Dib, Samy Anis Amine
    Meftah, Mustapha
    JOURNAL OF ATMOSPHERIC AND SOLAR-TERRESTRIAL PHYSICS, 2023, 248
  • [33] Proton Source Modeling for Geant4 Monte Carlo Simulations
    Barnes, S.
    McAuley, G.
    Wroe, A.
    Slater, J.
    MEDICAL PHYSICS, 2012, 39 (06) : 3756 - 3757
  • [34] Determination of Tungsten Target Parameters for Transmission X-ray Tube: A Simulation Study Using Geant4
    Nasseri, Mohammad M.
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2016, 48 (03) : 795 - 798
  • [35] Implementation of the reverse/adjoint Monte Carlo method into Geant4
    Desorgher, L.
    Lei, F.
    Santin, G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 621 (1-3): : 247 - 257
  • [36] Dynamic Monte Carlo Dose Calculations for IMRT in Geant4
    Hancox, C.
    Seco, J.
    Sharp, G.
    Peroni, M.
    Paganetti, H.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [37] In-Orbit Activation Study of ASTRO-H X-Ray Observatory Using Geant4
    Sato, Tamotsu
    Odaka, Hirokazu
    Hiragi, Kazuyoshi
    Mizuno, Sunefumi
    Ohno, Masatoshi
    Fukazawa, Yasushi
    Ohta, Masayuki
    Koseki, Yuu
    Watanabe, Shin
    Kokubun, Motohide
    Takahashi, Tadayuki
    Ozaki, Masanobu
    Asai, Makoto
    Tajima, Hiroyasu
    Yasuda, Tetsuya
    Terada, Yukikatsu
    Uchibori, Yukio
    Kitamura, Hisashi
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 1727 - 1730
  • [38] GXPS: A Geant4-based Monte Carlo code for x-ray polycapillary simulation
    Chi, Zhijun
    JOURNAL OF APPLIED PHYSICS, 2020, 128 (12)
  • [39] Parameterization models for X-ray transition radiation in the GEANT4 package
    Apostolakis, J
    Giani, S
    Maire, M
    Bagulya, AV
    Grichine, VM
    COMPUTER PHYSICS COMMUNICATIONS, 2000, 132 (03) : 241 - 250
  • [40] X-Ray Coherent Scatter Diffraction Pattern Modeling in GEANT4
    Kapadia, A.
    Samei, E.
    Harrawood, B.
    Sahbaee, P.
    Chawla, A.
    Tan, Z.
    Brady, D.
    MEDICAL PHYSICS, 2012, 39 (06) : 3642 - 3643