Monte Carlo study of X-ray grazing incidence microscopy using Geant4

被引:0
|
作者
Li, Wenjie [1 ,2 ]
Xu, Jie [1 ,2 ]
Yang, Cheng [1 ,2 ]
Li, Mingtao [1 ,2 ]
Wang, Xin [1 ,2 ]
Zhang, Xing [3 ]
Mu, Baozhong [1 ,2 ]
机构
[1] Tongji Univ, Key Lab Adv Microstruct Mat, Minist Educ, Shanghai 200092, Peoples R China
[2] Tongji Univ, Sch Phys Sci & Engn, Shanghai 200092, Peoples R China
[3] China Acad Engn Phys, Res Ctr Laser Fus, Mianyang 621900, Peoples R China
基金
中国国家自然科学基金;
关键词
KIRKPATRICK-BAEZ MICROSCOPE; TOTAL-REFLECTION; ANGLE;
D O I
10.1364/OE.497436
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
X-ray grazing incidence microscopy has extensive applications in the fields of laser inertial confinement fusion and synchrotron radiation. Monte Carlo methods can be used to determine the optical performance of X-ray grazing incidence microscopes and predict the experimental results, which is of great significance for studying physical experiments and diagnostics. In this paper, we proposed a Monte Carlo method based on Geant4 for studying X-ray grazing incidence microscopy. We introduced the G4MultilayerReflection class to describe the physical processes of X-ray multilayer mirrors. We designed a dual-energy Kirkpatrick-Baez microscope that can operate at 6.4 and 9.67 keV simultaneously. Monte Carlo simulations of the spatial resolution and throughput efficiency of the microscope were performed using Geant4, which was assembled and characterized. The spatial resolution results obtained by the Geant4 laboratory simulations, the theoretical model, and the experiments were in good agreement. Additionally, we conducted throughput efficiency calibration experiments for the 6.4 keV imaging channel. The difference between the experimental and Geant4-simulated throughput efficiency was evaluated and resulted in root mean square error values of 8.7% and 9.5% along the Y-and Z-axes, respectively.(c) 2023 Optica Publishing Group under the terms of the Optica Open Access Publishing Agreement
引用
收藏
页码:35453 / 35470
页数:18
相关论文
共 50 条
  • [1] X-ray tracing using Geant4
    Buis, E. J.
    Vacanti, G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 599 (2-3): : 260 - 263
  • [2] Validation of the Geant4 Monte Carlo package for X-ray fluorescence spectroscopy in triaxial geometry
    Amaro, Pedro
    Santos, Jose Paulo
    Samouco, Ana
    Adao, Ricardo
    Martins, Luis Souto
    Weber, Sebastian
    Tashenov, Stanislav
    Carvalho, Maria Luisa
    Pessanha, Sofia
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2017, 130 : 60 - 66
  • [3] Scatter in an uncollimated x-ray CT machine based on a Geant4 Monte Carlo simulation
    Wadeson, Nicola
    Morton, Edward
    Lionheart, William
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [4] Using Geant4 Monte Carlo toolkit to evaluate a low power X-ray tube generator configuration
    Hoff, G.
    Streck, E. E.
    Lai, A.
    Fanti, V
    Golosio, B.
    Nascimento, C. D.
    Souza, E. G.
    APPLIED RADIATION AND ISOTOPES, 2021, 168
  • [5] Monte Carlo simulation of scintillation behavior of zinc oxide under X-ray illumination using GEANT4
    Taheri, Ali
    Saramad, Shahyar
    Setayeshi, Saeed
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2013, 168 (02): : 153 - 162
  • [6] Sensitivity study of proton radiography and comparison with kV and MV x-ray imaging using GEANT4 Monte Carlo simulations
    Depauw, Nicolas
    Seco, Joao
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (08): : 2407 - 2421
  • [7] Experimental test of Monte Carlo proton transport at grazing incidence in GEANT4, FLUKA and MCNPX
    Kimstrand, Peter
    Tilly, Nina
    Ahnesjo, Anders
    Traneus, Erik
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (04): : 1115 - 1129
  • [8] The Geant4 Virtual Monte Carlo
    Hrivnacova, I.
    INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS 2012 (CHEP2012), PTS 1-6, 2012, 396
  • [9] GEANT4 Monte Carlo simulations for virtual clinical trials in breast X-ray imaging: Proof of concept
    di Franco, F.
    Sarno, A.
    Mettivier, G.
    Hernandez, A. M.
    Bliznakova, K.
    Boone, J. M.
    Russo, P.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 74 : 133 - 142
  • [10] Monte Carlo simulation of the ELIMED beamline using Geant4
    Pipek, J.
    Romano, F.
    Milluzzo, G.
    Cirrone, G. A. P.
    Cuttone, G.
    Amico, A. G.
    Margarone, D.
    Larosa, G.
    Leanza, R.
    Petringa, G.
    Schillaci, F.
    Scuderi, V.
    JOURNAL OF INSTRUMENTATION, 2017, 12