The Remove-the-Mask Open-Source head and neck Surface-Guided radiation therapy system

被引:0
|
作者
Ben Bouchta, Youssef [1 ]
Gardner, Mark [1 ]
Sengupta, Chandrima [1 ]
Johnson, Julia [1 ]
Keall, Paul [1 ]
机构
[1] Univ Sydney, Camperdown, NSW 2050, Australia
关键词
Surface-Guided Radiotherapy; Intra-Fraction Motion Monitoring; Open-Source; Head And Neck Radiotherapy; Image-Guided Radiotherapy; PATIENT SELF-REPORT; IMAGING-SYSTEM; RADIOTHERAPY; CANCER; IMMOBILIZATION; CARCINOMA; ANXIETY;
D O I
10.1016/j.phro.2024.100541
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and Purpose: Surface Guided Radiotherapy (SGRT) for head and neck radiotherapy is challenging as obstructions are common and non-rigid facial motion can compromise surface accuracy. The purpose of this work was to develop and benchmark the Remove the Mask (RtM) SGRT system, an open-source system especially designed to address the challenges faced in radiotherapy of head and neck cancer. Materials and Methods: The accuracy of the RtM SGRT system was benchmarked using a head phantom positioned on a robotic motion platform capable of sub-millimetre accuracy which was used to induce unidirectional shifts and to reproduce three real head motion traces. We also assessed the accuracy of the system in ten humans volunteers. The ground truth motion of the volunteers was obtained using a commercial motion capture system with an accuracy < 0.3 mm. Results: The mean tracking error of the RtM SGRT system for the ten volunteers was of -0.1 +/- 0.4 mm -0.6 +/- 0.6 mm and 0.3 +/- 0.2 mm, and 0.0 +/- 0.2(degrees) 0.0 +/- 0.1(degrees) and 0.0 +/- 0.2(degrees) for translations and rotations along the left-right, superior-inferior and anterior-posterior axes respectively and we also found similar results in measurements with the head phantom. Forced facial motion was associated with lower tracking accuracy. The RtM SGRT system achieved submillimetre accuracy. Conclusion: The RtM SGRT system is a low-cost, easy to build and open-source SGRT system that can achieve an accuracy that meets international commissioning guidelines. Its open-source and modular design allows for the development and easy translation of novel surface tracking techniques.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Open-source software for collision detection in external beam radiation therapy
    Suriyakumar, Vinith M.
    Xu, Renee
    Pinter, Csaba
    Fichtinger, Gabor
    MEDICAL IMAGING 2017: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2017, 10135
  • [32] Performing radiation therapy research using the open-source SlicerRT toolkit
    Pinter, Csaba
    Lasso, Andras
    Wang, An
    Sharp, Gregory C.
    Alexander, Kevin
    Jaffray, David
    Fichtinger, Gabor
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 622 - 625
  • [33] Magnetic Resonance-Guided Radiation Therapy for Head and Neck Cancers
    Lavigne, Danny
    Ng, Sweet Ping
    O'Sullivan, Brian
    Nguyen-Tan, Phuc Felix
    Filion, Edith
    Letourneau-Guillon, Laurent
    Fuller, Clifton D.
    Bahig, Houda
    CURRENT ONCOLOGY, 2022, 29 (11) : 8302 - 8315
  • [34] MR-guided stereotactic radiation therapy for head and neck cancers
    Wang, He
    Yang, Jinzhong
    Lee, Anna
    Phan, Jack
    Lim, Tze Yee
    Fuller, Clifton D.
    Han, Eun Young
    Rhee, Dong Joo
    Salzillo, Travis
    Zhao, Yao
    Chopra, Nitish
    Pham, Mary
    Castillo, Pam
    Sobremonte, Angela
    Moreno, Amy C.
    Reddy, Jay P.
    Rosenthal, David
    Garden, Adam S.
    Wang, Xin
    CLINICAL AND TRANSLATIONAL RADIATION ONCOLOGY, 2024, 46
  • [35] Three-Dimensional Surface-Guided Radiation Therapy in the Evaluation of Intrafraction Motion for Breast and Lung
    Jermoumi, M.
    Cao, D.
    Mehta, V. K.
    Shepard, D. M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E696 - E696
  • [36] The impact of a prophylactic skin dressing on surface-guided patient positioning in chest wall Radiation Therapy
    Cumming, James
    Thompson, Kenton
    Woodford, Katrina
    Panettieri, Vanessa
    Sapkaroski, Daniel
    JOURNAL OF MEDICAL RADIATION SCIENCES, 2024, 71 (02) : 177 - 185
  • [37] Development of automated region of interest selection algorithms for surface-guided radiation therapy of breast cancer
    Cui, Songye
    Li, Guang
    Kuo, Hsiang-Chi
    Zhao, Bo
    Li, Anyi
    Cervino, Laura I.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (01):
  • [38] Surface-guided setup and intrafraction motion in free-breathing breast cancer radiation therapy
    Kirkegaard, Trine O.
    Jensen, Ingelise
    Kristensen, Thomas O.
    Milo, Marie Louise H.
    Nielsen, Martin S.
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3994 - S3996
  • [39] Clinical Application of Radiobiological Modeling in the Histogram Analysis in Radiation Therapy (HART): An Open-source Software System in Radiation Oncology
    Pyakuryal, A.
    Sio, T. T. W.
    Narayanasamy, G.
    Lee, C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E537 - E537
  • [40] A prospective evaluation of open face masks for head and neck radiation therapy
    Wiant, David
    Squire, Sarah
    Liu, Han
    Maurer, Jacqueline
    Hayes, T. Lane
    Sintay, Benjamin
    PRACTICAL RADIATION ONCOLOGY, 2016, 6 (06) : E259 - E267