摘要
Background and Purpose: Surface Guided Radiotherapy (SGRT) for head and neck radiotherapy is challenging as obstructions are common and non-rigid facial motion can compromise surface accuracy. The purpose of this work was to develop and benchmark the Remove the Mask (RtM) SGRT system, an open-source system especially designed to address the challenges faced in radiotherapy of head and neck cancer. Materials and Methods: The accuracy of the RtM SGRT system was benchmarked using a head phantom positioned on a robotic motion platform capable of sub-millimetre accuracy which was used to induce unidirectional shifts and to reproduce three real head motion traces. We also assessed the accuracy of the system in ten humans volunteers. The ground truth motion of the volunteers was obtained using a commercial motion capture system with an accuracy < 0.3 mm. Results: The mean tracking error of the RtM SGRT system for the ten volunteers was of -0.1 +/- 0.4 mm -0.6 +/- 0.6 mm and 0.3 +/- 0.2 mm, and 0.0 +/- 0.2(degrees) 0.0 +/- 0.1(degrees) and 0.0 +/- 0.2(degrees) for translations and rotations along the left-right, superior-inferior and anterior-posterior axes respectively and we also found similar results in measurements with the head phantom. Forced facial motion was associated with lower tracking accuracy. The RtM SGRT system achieved submillimetre accuracy. Conclusion: The RtM SGRT system is a low-cost, easy to build and open-source SGRT system that can achieve an accuracy that meets international commissioning guidelines. Its open-source and modular design allows for the development and easy translation of novel surface tracking techniques.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Optimizing Isocenter Calibrations for Noncoplanar Treatments Using Surface-Guided Radiation Therapy
    Pinkham, D.
    Kamath, S.
    Hancock, S.
    MEDICAL PHYSICS, 2019, 46 (06) : E658 - E658
  • [22] Current Status of the Histogram Analysis in Radiation Therapy (HART): An Open-Source Software System
    Pyakuryal, A.
    Kepka, A.
    Gopalakrishnan, M.
    Jang, S.
    Sathiaseelan, V.
    Mittal, B.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [23] Treatment Planning System for Electron FLASH Radiation Therapy: Open-Source for Clinical Implementation
    Rahman, Mahbubur
    Ashraf, M. Ramish
    Gladstone, David J.
    Bruza, Petr
    Jarvis, Lesley A.
    Schaner, Philip E.
    Cao, Xu
    Pogue, Brian W.
    Hoopes, P. Jack
    Zhang, Rongxiao
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2022, 112 (04): : 1023 - 1032
  • [24] Clinical Application of the Histogram Analysis in Radiation Therapy (HART): An Open-Source Software System in Radiation Oncology
    Pyakuryal, A. P.
    Bacchus, I.
    Narayanasamy, G.
    Jang, S.
    Perez-Andujar, A.
    Sio, T. T.
    Kudrimoti, M.
    Mittal, B. B.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S626 - S627
  • [25] Surface-Guided Radiation Therapy Error Assessment: Impact of Surface Discrepancies in Breast Cancer Patients
    Tehrani, J. Nasehi
    MEDICAL PHYSICS, 2024, 51 (09) : 6639 - 6640
  • [26] Imaging-guided radiation therapy for head and neck cancer
    Chao, K. S. Clifford
    ORAL ONCOLOGY, 2011, 47 : S8 - S8
  • [27] CustusX: an open-source research platform for image-guided therapy
    Askeland, Christian
    Solberg, Ole Vegard
    Bakeng, Janne Beate Lervik
    Reinertsen, Ingerid
    Tangen, Geir Arne
    Hofstad, Erlend Fagertun
    Iversen, Daniel Hoyer
    Vapenstad, Cecilie
    Selbekk, Tormod
    Lango, Thomas
    Hernes, Toril A. Nagelhus
    Leira, Hakon Olav
    Unsgard, Geirmund
    Lindseth, Frank
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2016, 11 (04) : 505 - 519
  • [28] CustusX: an open-source research platform for image-guided therapy
    Christian Askeland
    Ole Vegard Solberg
    Janne Beate Lervik Bakeng
    Ingerid Reinertsen
    Geir Arne Tangen
    Erlend Fagertun Hofstad
    Daniel Høyer Iversen
    Cecilie Våpenstad
    Tormod Selbekk
    Thomas Langø
    Toril A. Nagelhus Hernes
    Håkon Olav Leira
    Geirmund Unsgård
    Frank Lindseth
    International Journal of Computer Assisted Radiology and Surgery, 2016, 11 : 505 - 519
  • [29] Maskless surface-guided head and neck cancer radiotherapy: Setup accuracy and intra-fraction motion
    Essers, Marion
    Mesch, Lennart
    Beugeling, Maaike
    Dekker, Janita
    de Kruijf, Willy
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S4289 - S4290
  • [30] Comparison of two thermoplastic immobilization mask systems in daily volumetric image guided radiation therapy for head and neck cancers
    Divneet, Mandair
    Ho Quoc-Anh
    Betsy, Wertheim
    Gia, Johnson
    Denise, Roe
    Christopher, Watchman
    Yi, Sun K.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2018, 4 (05):