Improvements in image quality after optimization in digital intraoral radiographs

被引:2
|
作者
Barrineau, Ashley B. [1 ]
Mah, Peter [2 ]
Mallya, Sanjay M. [3 ]
机构
[1] Univ Calif Los Angeles, Sch Dent, Sect Endodont, Los Angeles, CA USA
[2] Dent Imaging Consultants, Box 29214 Med Ctr Stn, San Antonio, TX 78229 USA
[3] Univ Calif Los Angeles, Sch Dent, Sect Maxillofacial Radiol, Los Angeles, CA USA
来源
关键词
Quality control; quality assurance; image optimization; digital radiography; exposure optimization; radiographic phantom; image analysis; ASSURANCE; ACCURACY;
D O I
10.1016/j.adaj.2022.09.008
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background. Digital intraoral radiographic exposures are optimized largely on the basis of subjective assessment of diagnostic image quality. This study presents an objective approach to optimize radiographic exposure settings for digital intraoral radiographic systems.Methods. Seven size 2 digital intraoral systems were assessed for image quality and determination of optimal exposure following the protocol specified in American National Standard Institute/American Dental Association Standard No. 1094: Quality Assurance for Digital Intra-Oral Radiographic Systems. A ProX radiograph unit (Planmeca) at 63 kVp and 6 mA was used to obtain radiographs of the Dental Digital Quality Assurance phantom. ImageJ software (National Institutes of Health) was used to quantify dynamic range and spatial resolution, and contrast perceptibility was evaluated visually. Optimal exposure is the setting with the maximal contrast perceptibility and spatial resolution while displaying the full dynamic range. After image optimization, a custom phantom consisting of an endodontically prepared tooth was imaged to evaluate the file position relative to the apex for each system. Differences in distances between file position relative to the root apex at the optimal exposure as well as 1 increment above and below were measured.Results. Radiographic images obtained at the optimal exposure yielded better visualization and more accurate measurements of the file tip relative to the apex.Conclusions. Optimizing radiographic exposures improves image quality and accuracy in clinical decisions.Practical Implications. Improvement in image quality and better accuracy in actual distance of the endodontic file to the radiographic apex coupled with complete cleaning, shaping, and obturation of the canal should lead to better endodontic treatment outcomes.
引用
收藏
页码:24 / 31
页数:8
相关论文
共 50 条
  • [41] Conventional and predicted Perceptibility Curves for contrast-enhanced direct digital intraoral radiographs
    Yoshiura, K
    Welander, U
    Shi, XQ
    Li, G
    Kawazu, T
    Tatsumi, M
    Okamura, K
    McDavid, WD
    Kanda, S
    DENTOMAXILLOFACIAL RADIOLOGY, 2001, 30 (04) : 219 - 225
  • [42] Effect of brightness and contrast variation for detectability of root resorption lesions in digital intraoral radiographs
    Eduarda Helena Leandro Nascimento
    Hugo Gaêta-Araujo
    Neiandro Santos Galvão
    Larissa Moreira-Souza
    Christiano Oliveira-Santos
    Deborah Queiroz Freitas
    Clinical Oral Investigations, 2019, 23 : 3379 - 3386
  • [43] Dose optimization and image quality measurement in digital abdominal radiography
    Karal, Omer
    Tokgoz, Nazime
    RADIATION PHYSICS AND CHEMISTRY, 2023, 205
  • [44] Dose Optimization and Image Quality in Digital Radiography: A Review Article
    Barai, Juhi
    Tivaskar, Suhas
    Sable, Apeksha
    Luharia, Anurag
    JOURNAL OF PHARMACEUTICAL NEGATIVE RESULTS, 2022, 13 (03) : 1076 - 1080
  • [45] Optimization of dose and image quality in pediatrics chest digital radiography
    Deevband, Mohammad Reza
    Rahmani, Fereshteh
    Bardar, Meisam Ebrahimi
    Ghorbani, Mahdi
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2021, 52 (03) : 443 - 449
  • [46] Effect of brightness and contrast variation for detectability of root resorption lesions in digital intraoral radiographs
    Leandro Nascimento, Eduarda Helena
    Gaeta-Araujo, Hugo
    Galvao, Neiandro Santos
    Moreira-Souza, Larissa
    Oliveira-Santos, Christiano
    Freitas, Deborah Queiroz
    CLINICAL ORAL INVESTIGATIONS, 2019, 23 (08) : 3379 - 3386
  • [47] Optimization of dose and image quality for computed radiography and digital radiography
    Aldrich, JE
    Duran, E
    Dunlop, P
    Mayo, JR
    JOURNAL OF DIGITAL IMAGING, 2006, 19 (02) : 126 - 131
  • [48] Optimization of Dose and Image Quality for Computed Radiography and Digital Radiography
    John E. Aldrich
    Emerenciana Duran
    Pat Dunlop
    John R. Mayo
    Journal of Digital Imaging, 2006, 19 : 126 - 131
  • [49] EFFECT OF IMAGE-ENHANCEMENT FOR DETECTABILITY OF BONE-LESIONS IN DIGITIZED INTRAORAL RADIOGRAPHS
    WENZEL, A
    SCANDINAVIAN JOURNAL OF DENTAL RESEARCH, 1988, 96 (02): : 149 - 160
  • [50] Influence of VistaScan image enhancement filters on diagnosis of simulated periapical lesions on intraoral radiographs
    Brasil, Danieli Moura
    Yamasaki, Mayra Cristina
    Santaella, Gustavo Machado
    Zumstein Guido, Maria Carolina
    Freitas, Deborah Queiroz
    Haiter-Neto, Francisco
    DENTOMAXILLOFACIAL RADIOLOGY, 2019, 48 (02)