Optimizing a high-sensitivity NanoLuc-based bioluminescence system for in vivo evaluation of antimicrobial treatment

被引:1
|
作者
Shang, Weilong [1 ]
Hu, Zhen [1 ]
Li, Mengyang [2 ]
Wang, Yuting [1 ]
Rao, Yifan [3 ]
Tan, Li [1 ]
Chen, Juan [4 ]
Huang, Xiaonan [1 ]
Liu, Lu [2 ]
Liu, He [1 ]
Guo, Zuwen [1 ]
Peng, Huagang [1 ]
Yang, Yi [1 ]
Hu, Qiwen [1 ]
Li, Shu [1 ]
Hu, Xiaomei [1 ]
Zou, Jiao [5 ]
Rao, Xiancai [1 ]
机构
[1] Army Med Univ, Mil Med Univ 3, Key Lab Microbial Engn Educ Comm Chongqing, Coll Basic Med Sci,Dept Microbiol, Chongqing, Peoples R China
[2] Chongqing Univ, Sch Med, Dept Microbiol, Chongqing, Peoples R China
[3] Army Med Univ, Mil Med Univ 3, Xinqiao Hosp, Dept Emergency Med, Chongqing, Peoples R China
[4] Army Med Univ, Mil Med Univ 3, Xinqiao Hosp, Dept Pharm, Chongqing, Peoples R China
[5] Army Med Univ, Mil Med Univ 3, Sch Psychol, Dept Mil Cognit Psychol, Chongqing, Peoples R China
来源
MLIFE | 2023年 / 2卷 / 04期
基金
中国国家自然科学基金;
关键词
antimicrobial evaluation; bioluminescence imaging; Nluc-based luciferases; Staphylococcus aureus; therapeutic efficacy; LUCIFERASE REPORTER; ANTIBIOTICS; EXPRESSION; MODELS; TOOLS;
D O I
10.1002/mlf2.12091
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Focal and systemic infections are serious threats to human health. Preclinical models enable the development of new drugs and therapeutic regimens. In vivo, animal bioluminescence (BL) imaging has been used with bacterial reporter strains to evaluate antimicrobial treatment effects. However, high-sensitivity bioluminescent systems are required because of the limited tissue penetration and low brightness of the BL signals of existing approaches. Here, we report that NanoLuc (Nluc) showed better performance than LuxCDABE in bacteria. However, the retention rate of plasmid constructs in bacteria was low. To construct stable Staphylococcus aureus reporter strains, a partner protein enolase (Eno) was identified by screening of S. aureus strain USA300 for fusion expression of Nluc-based luciferases, including Nluc, Teluc, and Antares2. Different substrates, such as hydrofurimazine (HFZ), furimazine (FUR), and diphenylterazine (DTZ), were used to optimize a stable reporter strain/substrate pair for BL imaging. S. aureus USA300/Eno-Antares2/HFZ produced the highest number of photons of orange-red light in vitro and enabled sensitive BL tracking of S. aureus in vivo, with sensitivities of approximately 10 CFU from mouse skin and 750 CFU from mouse kidneys. USA300/Eno-Antares2/HFZ was a powerful combination based on the longitudinal evaluation of the therapeutic efficacy of antibiotics. The optimized S. aureus Eno-Antares2/HFZ pair provides a technological advancement for the in vivo evaluation of antimicrobial treatment.
引用
收藏
页码:462 / 478
页数:17
相关论文
共 50 条
  • [41] Development of a high-sensitivity tune measurement system based on diode-detection at HLS-II
    Lan, Jinkai
    Zhou, Tianyu
    Sun, Baogen
    Wang, Chuhan
    Yang, Yongliang
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1039
  • [42] A distributed-feedback fibre laser based optical fibre hydrophone system with very high-sensitivity
    Leung, I
    Brodzeli, Z
    Whitbread, T
    Chen, XB
    Peng, GD
    ADVANCED SENSOR SYSTEMS AND APPLICATIONS II PT 1AND 2, 2004, 5634 : 434 - 443
  • [43] A multifrequency-resonator-based system for high-sensitivity high-field EPR investigations of small single crystals
    Hill, S
    Dalal, NS
    Brooks, JS
    APPLIED MAGNETIC RESONANCE, 1999, 16 (02) : 237 - 245
  • [44] In vivo Estimation of Breast Cancer Tissue Volume in Subcutaneous Xenotransplantation Mouse Models by Using a High-Sensitivity Fiber-Based Terahertz Scanning Imaging System
    Chen, Hua
    Han, Juan
    Wang, Dan
    Zhang, Yu
    Li, Xiao
    Chen, Xiaofeng
    FRONTIERS IN GENETICS, 2021, 12
  • [45] A High-Sensitivity Magnetic Moment Measurement System for Large Samples Based on a Single-Axis Atomic Magnetometer
    Sun, Yongze
    Zhou, Yuanrui
    Wang, Xixi
    Bai, Dongxu
    Wang, Yanzhang
    Zhou, Zhijian
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73 : 1 - 11
  • [46] A Novel High-sensitivity Cardiac Multi-biomarkers Detecting System Based on Microfluidic Chip and GMR Sensor
    Huo, W.
    Gao, Y.
    Zhang, L.
    Shi, S.
    Gao, Y.
    2015 IEEE MAGNETICS CONFERENCE (INTERMAG), 2015,
  • [47] In vivo evaluation of chitosan based local delivery system for atorvastatin in treatment of periodontitis
    Ozdogan, A. Isilay
    Ilarslan, Yagmur D.
    Kosemehmetoglu, Kemal
    Akca, Gulcin
    Kutlu, H. Burak
    Comerdov, Elnur
    Iskit, Alper B.
    Senel, Sevda
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2018, 550 (1-2) : 470 - 476
  • [48] Filter-based method for background removal in high-sensitivity wide-field-surface-enhanced Raman scattering imaging in vivo
    Mallia, Rupananda J.
    McVeigh, Patrick Z.
    Veilleux, Israel
    Wilson, Brian C.
    JOURNAL OF BIOMEDICAL OPTICS, 2012, 17 (07)
  • [49] A high-sensitivity and long-distance structural health monitoring system based on bidirectional SH wave phased array
    Huan, Qiang
    Chen, Mingtong
    Li, Faxin
    ULTRASONICS, 2020, 108 (108)
  • [50] Analytical characterization and clinical performance evaluation of a new point-of-care testing system for high-sensitivity cardiac troponin I assay
    Zhang, Rui
    Hong, Yueyu
    Shi, Jie
    Zhao, Rui
    Song, Yichuan
    Li, Ziyao
    Wang, Qingtao
    ANNALS OF CLINICAL BIOCHEMISTRY, 2021, 58 (06) : 579 - 585