Optimizing a high-sensitivity NanoLuc-based bioluminescence system for in vivo evaluation of antimicrobial treatment

被引:1
|
作者
Shang, Weilong [1 ]
Hu, Zhen [1 ]
Li, Mengyang [2 ]
Wang, Yuting [1 ]
Rao, Yifan [3 ]
Tan, Li [1 ]
Chen, Juan [4 ]
Huang, Xiaonan [1 ]
Liu, Lu [2 ]
Liu, He [1 ]
Guo, Zuwen [1 ]
Peng, Huagang [1 ]
Yang, Yi [1 ]
Hu, Qiwen [1 ]
Li, Shu [1 ]
Hu, Xiaomei [1 ]
Zou, Jiao [5 ]
Rao, Xiancai [1 ]
机构
[1] Army Med Univ, Mil Med Univ 3, Key Lab Microbial Engn Educ Comm Chongqing, Coll Basic Med Sci,Dept Microbiol, Chongqing, Peoples R China
[2] Chongqing Univ, Sch Med, Dept Microbiol, Chongqing, Peoples R China
[3] Army Med Univ, Mil Med Univ 3, Xinqiao Hosp, Dept Emergency Med, Chongqing, Peoples R China
[4] Army Med Univ, Mil Med Univ 3, Xinqiao Hosp, Dept Pharm, Chongqing, Peoples R China
[5] Army Med Univ, Mil Med Univ 3, Sch Psychol, Dept Mil Cognit Psychol, Chongqing, Peoples R China
来源
MLIFE | 2023年 / 2卷 / 04期
基金
中国国家自然科学基金;
关键词
antimicrobial evaluation; bioluminescence imaging; Nluc-based luciferases; Staphylococcus aureus; therapeutic efficacy; LUCIFERASE REPORTER; ANTIBIOTICS; EXPRESSION; MODELS; TOOLS;
D O I
10.1002/mlf2.12091
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Focal and systemic infections are serious threats to human health. Preclinical models enable the development of new drugs and therapeutic regimens. In vivo, animal bioluminescence (BL) imaging has been used with bacterial reporter strains to evaluate antimicrobial treatment effects. However, high-sensitivity bioluminescent systems are required because of the limited tissue penetration and low brightness of the BL signals of existing approaches. Here, we report that NanoLuc (Nluc) showed better performance than LuxCDABE in bacteria. However, the retention rate of plasmid constructs in bacteria was low. To construct stable Staphylococcus aureus reporter strains, a partner protein enolase (Eno) was identified by screening of S. aureus strain USA300 for fusion expression of Nluc-based luciferases, including Nluc, Teluc, and Antares2. Different substrates, such as hydrofurimazine (HFZ), furimazine (FUR), and diphenylterazine (DTZ), were used to optimize a stable reporter strain/substrate pair for BL imaging. S. aureus USA300/Eno-Antares2/HFZ produced the highest number of photons of orange-red light in vitro and enabled sensitive BL tracking of S. aureus in vivo, with sensitivities of approximately 10 CFU from mouse skin and 750 CFU from mouse kidneys. USA300/Eno-Antares2/HFZ was a powerful combination based on the longitudinal evaluation of the therapeutic efficacy of antibiotics. The optimized S. aureus Eno-Antares2/HFZ pair provides a technological advancement for the in vivo evaluation of antimicrobial treatment.
引用
收藏
页码:462 / 478
页数:17
相关论文
共 50 条
  • [31] High-sensitivity capacitive readout system for resonant submicrometer-scale cantilevers based sensors
    Verd, J
    Abadal, G
    Teva, J
    Uranga, A
    Barniol, N
    Esteve, J
    Duch, M
    Pérez-Murano, F
    2005 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), VOLS 1-6, CONFERENCE PROCEEDINGS, 2005, : 4209 - 4212
  • [32] Ultra-wide range and high-sensitivity temperature sensor based on a simple SPR system
    Gao, Zhigang
    Chen, Hailiang
    Feng, Yuhui
    Ullah, Sajid
    Li, Hongwei
    Jing, Xili
    Li, Shuguang
    INFRARED PHYSICS & TECHNOLOGY, 2023, 131
  • [33] A Novel High-Sensitivity Cardiac Multibiomarker Detection System Based on Microfluidic Chip and GMR Sensors
    Huo, Weisong
    Gao, Yuzhe
    Zhang, Lei
    Shi, Stone
    Gao, Yunhua
    IEEE TRANSACTIONS ON MAGNETICS, 2015, 51 (11)
  • [34] LIG-Based High-Sensitivity Multiplexed Sensing System for Simultaneous Monitoring of Metabolites and Electrolytes
    Park, Sang Hyun
    Pak, James Jungho
    SENSORS, 2024, 24 (21)
  • [35] A Phototransistor-Based High-Sensitivity Biosensing System Using 650-nm Light
    Chang, Yu-Wei
    Tai, Yu-Ting
    Huang, Yang-Tung
    Yang, Yuh-Shyong
    IEEE SENSORS JOURNAL, 2009, 9 (5-6) : 673 - 677
  • [36] High-sensitivity laser-based ultrasonic C-scan system for materials inspection
    F. Lanza di Scalea
    R. E. Green
    Experimental Mechanics, 1999, 39 : 329 - 334
  • [37] A High-Speed and High-Sensitivity Photon-Counting Communication System Based on Multichannel SPAD Detection
    Wen, Guanhua
    Huang, Jun
    Zhang, Liang
    Li, Changkun
    Wen, Tiancheng
    Wang, Jianyu
    IEEE PHOTONICS JOURNAL, 2021, 13 (02):
  • [38] High-sensitivity ICP-MS - an alternative for in vitro and in vivo characterization of future radiometal-based theranostic candidates
    Wallimann, Rahel
    Kneuer, Rainer
    Hensinger, Heloise
    Schindler, Patrick
    Becker, Anna
    Mueller, Cristina
    Schibli, Roger
    NUCLEAR MEDICINE AND BIOLOGY, 2022, 108 : S42 - S43
  • [39] On the Feasibility of a High-Sensitivity Imaging System for Biomedical Applications Based on Low-Frequency Magnetic Field
    Rotundo, Sabrina
    Brizi, Danilo
    Monorchio, Agostino
    IEEE JOURNAL OF ELECTROMAGNETICS RF AND MICROWAVES IN MEDICINE AND BIOLOGY, 2023, 7 (04): : 400 - 407
  • [40] A multifrequency-resonator-based system for high-sensitivity high-field EPR investigations of small single crystals
    S. Hill
    N. S. Dalal
    J. S. Brooks
    Applied Magnetic Resonance, 1999, 16 : 237 - 245