Evaluation and Comparison of Different Methods for Improving Fault Ride-Through Capability in Grid-Tied Permanent Magnet Synchronous Wind Generators

被引:20
|
作者
Mahmoud, Mohamed Metwally [1 ]
Atia, Basiony S. [2 ]
Esmail, Yahia M. [3 ]
Bajaj, Mohit [4 ,5 ,6 ]
Wapet, Daniel Eutyche Mbadjoun [7 ]
Ratib, Mohamed Khalid [7 ]
Hossain, Md. Biplob [8 ]
AboRas, Kareem M. [9 ]
Abdel-Rahim, Abdel-Moamen M. [1 ]
机构
[1] Aswan Univ, Fac Energy Engn, Elect Engn Dept, Aswan 81528, Egypt
[2] Field Serv Engineer Rapiscan Syst, 2805 Columbia St, Torrance, CA 90503 USA
[3] Minist Elect & Renewable Energy, Cairo, Egypt
[4] Graphic Era Deemed Univ, Dept Elect Engn, Dehra Dun 248002, India
[5] G Era Hill Univ, Dehra Dun 248002, India
[6] Appl Sci Private Univ, Appl Sci Res Ctr, Amman, Jordan
[7] Univ Yaounde I, Natl Adv Sch Engn, Yaounde, Cameroon
[8] Univ Wollongong, Fac Engn & Informat Sci, Wollongong, NSW 2522, Australia
[9] Alexandria Univ, Fac Engn, Dept Elect Power & Machines, Alexandria, Egypt
关键词
LOW-VOLTAGE RIDE; ENERGY-CONVERSION SYSTEMS; PHOTOVOLTAIC POWER-PLANTS; FED INDUCTION GENERATOR; CONTROL STRATEGY; COMMUTATION FAILURE; COORDINATED CONTROL; STORAGE SYSTEMS; TURBINES; IMPROVEMENT;
D O I
10.1155/2023/7717070
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Several advantages make wind-driven permanent magnet synchronous generators (PMSGs) very promising in the wind energy market, especially their fault ride-through capabilities. With the high penetration levels of today, both the grid and wind power (WP) systems are being affected by each other. Due to grid faults, the DC-bus in PMSG systems typically experiences overvoltage, which can negatively affect the generator parameters and trip the system. However, advancements in power electronics, control systems, fault limiters, FACTS, and energy storage technology make it possible to find and design satisfactory solutions and approaches. The most recent FRTC-improving techniques are mainly modified or external techniques based on controllers in PMSG-based WP. This paper evaluates the in-depth schemes of FRTC, introducing the underlying theory and traits of the different approaches to highlight the advantages and drawbacks of each. Five scenarios of DC-link voltage under zero-grid voltage are carried out by using the MATLAB SIMULINK program to assess the FRTC methods. This study shows that external device-based approaches can be efficient, but some of them are expensive, thus updated controller methods are recommended to cut costs. Research findings of this study are expected to support the deployment of FRTC technologies, as well as provide valuable input into WP research on grid integration.
引用
收藏
页数:22
相关论文
共 50 条
  • [41] Impact of fault ride-through methods on wind power generators in a VSC-HVDC system
    Li, Xuan
    Song, Qiang
    Liu, Wenhua
    Ma, Yulong
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2015, 39 (11): : 31 - 36
  • [42] Low Voltage Ride-through Control for Fixed Speed Wind Generators under Grid Unbalanced Fault
    Ren, Jiajia
    Hu, Yinghong
    Ji, Yanchao
    Liu, Chuang
    2012 TWENTY-SEVENTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC), 2012, : 686 - 689
  • [43] Fault Ride-through Technology of Hybrid HVDC Wind Power System Based on Multi-phase Permanent Magnet Synchronous Generator
    Liu Y.
    Zeng X.
    Luo Y.
    Zhang S.
    Wei M.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2020, 44 (08): : 133 - 140
  • [44] Fault Characteristic and Low Voltage Ride-Through Requirements Applicability Analysis for a Permanent Magnet Synchronous Generator-Based Wind Farm
    Chen, Wei
    Zheng, Taiying
    Han, Junfei
    ENERGIES, 2019, 12 (17)
  • [45] Grid-fault ride-through analysis and control of wind turbines with doubly fed induction generators
    Rahimi, Mohsen
    Parniani, Mostafa
    ELECTRIC POWER SYSTEMS RESEARCH, 2010, 80 (02) : 184 - 195
  • [46] Simulation research on Fault Ride Through for Permanent Magnet Synchronous generator Wind Power System
    Du Zhen-hua
    Ma Xiao-chun
    ELECTRONIC INFORMATION AND ELECTRICAL ENGINEERING, 2012, 19 : 642 - 645
  • [47] Simulation Research on Fault Ride Through for Permanent Magnet Synchronous Generator Wind Power System
    Ma, Xiping
    Dong, Kaisong
    Zhao, Yao
    Zheng, Xiangyu
    Yang, Jun
    PROCEEDINGS OF THE 2014 9TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA), 2014, : 1387 - 1391
  • [48] Modeling, Sizing, and Control of an Excitation Booster for Enhancement of Synchronous Generators Fault Ride-Through Capability: Experimental Validation
    Diez-Maroto, Luis
    Rouco, Luis
    Fernandez-Bernal, Fidel
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2016, 31 (04) : 1304 - 1314
  • [49] Enhancement of low-voltage ride-through capability of permanent magnet synchronous generator wind turbine by applying state-estimation technique
    Shahriari, Sayyed Ali Akbar
    Mohammadi, Mohammad
    Raoofat, Mahdi
    COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2020, 39 (02) : 363 - 377
  • [50] Analysis and Control of Fault Ride-Through Capability Improvement for Wind Turbine Based on a Permanent Magnet Synchronous Generator Using an Interval Type-2 Fuzzy Logic System
    Gencer, Altan
    ENERGIES, 2019, 12 (12)