Evaluation and Comparison of Different Methods for Improving Fault Ride-Through Capability in Grid-Tied Permanent Magnet Synchronous Wind Generators

被引:20
|
作者
Mahmoud, Mohamed Metwally [1 ]
Atia, Basiony S. [2 ]
Esmail, Yahia M. [3 ]
Bajaj, Mohit [4 ,5 ,6 ]
Wapet, Daniel Eutyche Mbadjoun [7 ]
Ratib, Mohamed Khalid [7 ]
Hossain, Md. Biplob [8 ]
AboRas, Kareem M. [9 ]
Abdel-Rahim, Abdel-Moamen M. [1 ]
机构
[1] Aswan Univ, Fac Energy Engn, Elect Engn Dept, Aswan 81528, Egypt
[2] Field Serv Engineer Rapiscan Syst, 2805 Columbia St, Torrance, CA 90503 USA
[3] Minist Elect & Renewable Energy, Cairo, Egypt
[4] Graphic Era Deemed Univ, Dept Elect Engn, Dehra Dun 248002, India
[5] G Era Hill Univ, Dehra Dun 248002, India
[6] Appl Sci Private Univ, Appl Sci Res Ctr, Amman, Jordan
[7] Univ Yaounde I, Natl Adv Sch Engn, Yaounde, Cameroon
[8] Univ Wollongong, Fac Engn & Informat Sci, Wollongong, NSW 2522, Australia
[9] Alexandria Univ, Fac Engn, Dept Elect Power & Machines, Alexandria, Egypt
关键词
LOW-VOLTAGE RIDE; ENERGY-CONVERSION SYSTEMS; PHOTOVOLTAIC POWER-PLANTS; FED INDUCTION GENERATOR; CONTROL STRATEGY; COMMUTATION FAILURE; COORDINATED CONTROL; STORAGE SYSTEMS; TURBINES; IMPROVEMENT;
D O I
10.1155/2023/7717070
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Several advantages make wind-driven permanent magnet synchronous generators (PMSGs) very promising in the wind energy market, especially their fault ride-through capabilities. With the high penetration levels of today, both the grid and wind power (WP) systems are being affected by each other. Due to grid faults, the DC-bus in PMSG systems typically experiences overvoltage, which can negatively affect the generator parameters and trip the system. However, advancements in power electronics, control systems, fault limiters, FACTS, and energy storage technology make it possible to find and design satisfactory solutions and approaches. The most recent FRTC-improving techniques are mainly modified or external techniques based on controllers in PMSG-based WP. This paper evaluates the in-depth schemes of FRTC, introducing the underlying theory and traits of the different approaches to highlight the advantages and drawbacks of each. Five scenarios of DC-link voltage under zero-grid voltage are carried out by using the MATLAB SIMULINK program to assess the FRTC methods. This study shows that external device-based approaches can be efficient, but some of them are expensive, thus updated controller methods are recommended to cut costs. Research findings of this study are expected to support the deployment of FRTC technologies, as well as provide valuable input into WP research on grid integration.
引用
收藏
页数:22
相关论文
共 50 条
  • [11] Research on fault ride-through capacity of direct driven wind turbine with permanent magnet synchronous generator under grid asymmetric faults
    Zhang, Xiaoying
    Cheng, Zhizhuang
    Guo, Yongji
    Wang, Xiaolan
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2014, 6 (04)
  • [12] Asymmetrical Fault Ride-Through and Power Oscillation Characterization for Grid-Tied Voltage Source Converters
    Rachi, Md Rifat Kaisar
    Awal, M. A.
    Husain, Iqbal
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2023, 59 (04) : 4550 - 4561
  • [13] Increase of fault ride-through capability for the grid-connected wind farms
    Ko, H. S.
    Jatskevich, J.
    Dumont, G. A.
    Moshref, A.
    2006 POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-9, 2006, : 718 - +
  • [14] Enhancement of fault ride-through capability of grid-connected wind farm
    Bhadane K.V.
    Ballal M.S.
    Moharil R.M.
    Kulkarni H.R.
    Prasad H.
    International Journal of Power Electronics, 2021, 13 (03) : 267 - 280
  • [15] Enhancement of fault ride-through capability for grid-connected wind farm
    Sun, Shixian
    Tian, Jie
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2013, 33 (08): : 137 - 141
  • [16] Low Voltage Ride-Through of Wind Turbine based on Interior Permanent Magnet Synchronous Generators Sensorless Vector Controlled
    Rizo, Mario
    Rodriguez, Ana
    Bueno, Emilio
    Rodriguez, Francisco J.
    Giron, Carlos
    2010 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION, 2010, : 2507 - 2514
  • [17] Improving fault ride-through capability of wind generation system using DVR
    Amutha, N.
    Kumar, B. Kalyan
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2013, 46 : 326 - 333
  • [18] Fault ride-through capability enhancement of doubly-fed induction wind generators
    Mohseni, M.
    Islam, S.
    Masoum, M. A. S.
    IET RENEWABLE POWER GENERATION, 2011, 5 (05) : 368 - 376
  • [19] Evaluation of Low Voltage Ride-Through Capability of Synchronous Generator Connected to a Grid
    Yang Shicong
    Shagar, G. Viknash
    Ukil, Abhisek
    Jayasinghe, S. D. Gamini
    Gupta, Amit K.
    2015 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, 2015,
  • [20] Unbalanced Voltage Sag Ride-through Capability for Three-phase Grid-tied Inverter with Low Inductance
    Nagai, Satoshi
    Itoh, Jun-ichi
    2020 IEEE 21ST WORKSHOP ON CONTROL AND MODELING FOR POWER ELECTRONICS (COMPEL), 2020, : 35 - 42