Development of CMOS dosimetry in proton minibeams for enhanced QA and primary standard absorbed dose calorimetry

被引:2
|
作者
Flynn, Samuel [1 ,2 ]
Allport, Philip [2 ]
De Marzi, Ludovic [3 ]
Green, Stuart [4 ]
Homer, Michael [1 ]
Lee, Nigel [1 ]
Ortiz, Ramon [3 ,5 ]
Patriarca, Annalisa [3 ]
Prezado, Yolanda [3 ,5 ]
Thomas, Russell [1 ,6 ]
Price, Tony [1 ,2 ]
机构
[1] Natl Phys Lab, Med Radiat Sci Grp, Hampton Rd, Teddington TW11 0LW, England
[2] Univ Birmingham, Sch Phys & Astron, Edgbaston Campus, Birmingham B15 2TT, England
[3] Univ PSL, Inst Curie, CNRS UMR3347, Inserm U1021,Signalisat Radiobiol & Canc, F-91898 Orsay, France
[4] Univ Hosp Birmingham NHS Trust, Med Phys, Mindelsohn Way, Birmingham B15 2TH, England
[5] Univ Paris Saclay, CNRS UMR3347, Inserm U1021, Signalisat Radiobiol & Canc, F-91400 Orsay, France
[6] Univ Surrey, Fac Engn & Phys Sci, Stag Hill, Guildford GU2 7XH, England
基金
欧洲研究理事会;
关键词
Dosimetry concepts and apparatus; Instrumentation for hadron therapy; MICROBEAM; RADIOTHERAPY;
D O I
10.1088/1748-0221/18/03/P03014
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Performing accurate and reliable dosimetry in spatially fractionated beams remains a significant challenge due to the steep dose gradients and microscopic scale of features. This results in many conventional detectors and instrumentation being unsuitable for online dosimetry, necessitating frequent offline validation using radiochromic film.In this study, the use of a Complementary Metal-Oxide-Semiconductor (CMOS) detector for evaluation of relative real-time dosimetry of proton minibeam radiation therapy (pMBRT) was investigated. The linearity of the CMOS detector was investigated by varying the proton beam current, with a comparison to a PTW 34001 Roos ionisation chamber used to carry out an independent check. It was found that the relative peaks and valleys of the pMBRT beam could be measured, with results comparable to EBT3XD film. The high sensitivity of the CMOS detector meant it was able to measure dose profiles from peak to valley regions, something not possible with the EBT3XD. The CMOS detector was compared to the treatment delivery log files, with correlation in beam positionseen as the beam is scanned along each slit, but not across; and agreement in beam intensity, with the CMOS detector able to observe beam interruptions.Lastly, the CMOS detector was used in conjunction with the NPL primary-standard proton calorimeter (NPL PSPC) for a preliminary study on combining the NPL PSPC with high resolution temporal information about the incident pMBRT beam. The ultimate aim of this approach is to facilitate detailed thermal modelling to reduce the overall uncertainty in the absolute dose measured from the calorimeter. In these experiments, saturation in the CMOS pixels prevented further thermal modelling of the radiation induced heat flow, however the instantaneous dose rate was observed to be comparable with the predicted NPL PSPC response obtained by masking the CMOS detector.
引用
收藏
页数:24
相关论文
共 50 条
  • [41] The effect of iodine uptake on radiation dose absorbed by patient tissues in contrast enhanced CT imaging: Implications for CT dosimetry
    Kostas Perisinakis
    Antonis Tzedakis
    Kostas Spanakis
    Antonios E. Papadakis
    Adam Hatzidakis
    John Damilakis
    European Radiology, 2018, 28 : 151 - 158
  • [42] The effect of iodine uptake on radiation dose absorbed by patient tissues in contrast enhanced CT imaging: Implications for CT dosimetry
    Perisinakis, Kostas
    Tzedakis, Antonis
    Spanakis, Kostas
    Papadakis, Antonios E.
    Hatzidakis, Adam
    Damilakis, John
    EUROPEAN RADIOLOGY, 2018, 28 (01) : 151 - 158
  • [43] METHOD OF TRANSFERRING SIZE OF UNIT OF ABSORBED DOSE INTENSITY FROM STATE PRIMARY STANDARD TO A STANDARD FACILITY FOR MEASURING ABSORBED DOSE OF GAMMA-RADIATION FROM CO-60 IN MUSCLE-TISSUE
    BREGADZE, YI
    MURATOV, NI
    TULTAEV, AV
    MEASUREMENT TECHNIQUES, 1975, 18 (03) : 444 - 446
  • [44] Direct determination of the absorbed dose to water from 125I low dose-rate brachytherapy seeds using the new absorbed dose primary standard developed at ENEA-INMRI
    Toni, M. P.
    Pimpinella, M.
    Pinto, M.
    Quini, M.
    Cappadozzi, G.
    Silvestri, C.
    Bottauscio, O.
    METROLOGIA, 2012, 49 (05) : S193 - S197
  • [45] Transfer of the UK absorbed dose primary standard for photon beams from the research linac to the clinical linac at NPL
    Pearce, J. A. D.
    Shipley, D. R.
    Duane, S.
    METROLOGIA, 2011, 48 (05) : 365 - 374
  • [46] National primary standard for the units of absorbed dose rate of photon and electron radiation, improvements and results of key comparisons
    A. V. Berlyand
    V. A. Berlyand
    Yu. I. Bregadze
    Measurement Techniques, 2010, 53 : 115 - 122
  • [47] PRIMARY STANDARD FOR THE DETERMINATION OF ABSORBED DOSE IN A PHANTOM FOR X-RAYS GENERATED AT POTENTIALS OF 7.5 TO 30 KV
    BOHM, J
    HOHLFELD, K
    REICH, H
    PTB-MITTEILUNGEN, 1979, 89 (03): : 163 - 172
  • [48] NATIONAL PRIMARY STANDARD FOR THE UNITS OF ABSORBED DOSE RATE OF PHOTON AND ELECTRON RADIATION, IMPROVEMENTS AND RESULTS OF KEY COMPARISONS
    Berlyand, A. V.
    Berlyand, V. A.
    Bregadze, Yu. I.
    MEASUREMENT TECHNIQUES, 2010, 53 (02) : 115 - 122
  • [49] An absorbed dose to water standard for HDR 192Ir brachytherapy sources based on water calorimetry:: Numerical and experimental proof-of-principle
    Sarfehnia, Arman
    Stewart, Kristin
    Seuntjensb, Jan
    MEDICAL PHYSICS, 2007, 34 (12) : 4957 - 4961
  • [50] Development of a log file analysis tool for proton patient QA, system performance tracking, and delivered dose reconstruction
    Ates, Ozgur
    Pirlepesov, Fakhriddin
    Zhao, Li
    Hua, Chia-ho
    Merchant, Thomas E.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (07):