Development of CMOS dosimetry in proton minibeams for enhanced QA and primary standard absorbed dose calorimetry

被引:2
|
作者
Flynn, Samuel [1 ,2 ]
Allport, Philip [2 ]
De Marzi, Ludovic [3 ]
Green, Stuart [4 ]
Homer, Michael [1 ]
Lee, Nigel [1 ]
Ortiz, Ramon [3 ,5 ]
Patriarca, Annalisa [3 ]
Prezado, Yolanda [3 ,5 ]
Thomas, Russell [1 ,6 ]
Price, Tony [1 ,2 ]
机构
[1] Natl Phys Lab, Med Radiat Sci Grp, Hampton Rd, Teddington TW11 0LW, England
[2] Univ Birmingham, Sch Phys & Astron, Edgbaston Campus, Birmingham B15 2TT, England
[3] Univ PSL, Inst Curie, CNRS UMR3347, Inserm U1021,Signalisat Radiobiol & Canc, F-91898 Orsay, France
[4] Univ Hosp Birmingham NHS Trust, Med Phys, Mindelsohn Way, Birmingham B15 2TH, England
[5] Univ Paris Saclay, CNRS UMR3347, Inserm U1021, Signalisat Radiobiol & Canc, F-91400 Orsay, France
[6] Univ Surrey, Fac Engn & Phys Sci, Stag Hill, Guildford GU2 7XH, England
基金
欧洲研究理事会;
关键词
Dosimetry concepts and apparatus; Instrumentation for hadron therapy; MICROBEAM; RADIOTHERAPY;
D O I
10.1088/1748-0221/18/03/P03014
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Performing accurate and reliable dosimetry in spatially fractionated beams remains a significant challenge due to the steep dose gradients and microscopic scale of features. This results in many conventional detectors and instrumentation being unsuitable for online dosimetry, necessitating frequent offline validation using radiochromic film.In this study, the use of a Complementary Metal-Oxide-Semiconductor (CMOS) detector for evaluation of relative real-time dosimetry of proton minibeam radiation therapy (pMBRT) was investigated. The linearity of the CMOS detector was investigated by varying the proton beam current, with a comparison to a PTW 34001 Roos ionisation chamber used to carry out an independent check. It was found that the relative peaks and valleys of the pMBRT beam could be measured, with results comparable to EBT3XD film. The high sensitivity of the CMOS detector meant it was able to measure dose profiles from peak to valley regions, something not possible with the EBT3XD. The CMOS detector was compared to the treatment delivery log files, with correlation in beam positionseen as the beam is scanned along each slit, but not across; and agreement in beam intensity, with the CMOS detector able to observe beam interruptions.Lastly, the CMOS detector was used in conjunction with the NPL primary-standard proton calorimeter (NPL PSPC) for a preliminary study on combining the NPL PSPC with high resolution temporal information about the incident pMBRT beam. The ultimate aim of this approach is to facilitate detailed thermal modelling to reduce the overall uncertainty in the absolute dose measured from the calorimeter. In these experiments, saturation in the CMOS pixels prevented further thermal modelling of the radiation induced heat flow, however the instantaneous dose rate was observed to be comparable with the predicted NPL PSPC response obtained by masking the CMOS detector.
引用
收藏
页数:24
相关论文
共 50 条
  • [21] Commissioning of a water calorimeter as a primary standard for absorbed dose to water in magnetic fields
    de Prez, Leon
    de Pooter, Jacco
    Jansen, Bartel
    Woodings, Simon
    Wolthaus, Jochem
    van Asselen, Bram
    van Soest, Theo
    Kok, Jan
    Raaymakers, Bas
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (03):
  • [22] The UK primary standard calorimeter for photon-beam absorbed dose measurement
    DuSautoy, AR
    PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (01): : 137 - 151
  • [23] A Feasibility Study of Fricke Dosimetry as an Absorbed Dose to Water Standard for 192Ir HDR Sources
    deAlmeida, Carlos Eduardo
    Ochoa, Ricardo
    de Lima, Marilene Coelho
    David, Mariano Gazineu
    Pires, Evandro Jesus
    Peixoto, Jose Guilherme
    Salata, Camila
    Bernal, Mario Antonio
    PLOS ONE, 2014, 9 (12):
  • [24] TRACEABILITY TO ABSORBED-DOSE-TO-WATER PRIMARY STANDARDS IN DOSIMETRY OF BRACHYTHERAPY SOURCES USED FOR RADIOTHERAPY
    Bovi, Maurizio
    Toni, Maria Pia
    Aubineau-Laniece, Isabelle
    Bordy, Jean-Marc
    Cardoso, Joao
    Chauvenet, Bruno
    Gabris, Frantisek
    Grindborg, Jan-Erik
    Guerra, Antonio Stefano
    Kosunen, Antti
    Oliveira, Carlos
    Pimpinella, Maria
    Sander, Thorsten
    Selbach, Hans-Joachim
    Sochor, Vladimir
    Solc, Jaroslav
    de Pooter, Jacco
    van Dijk, Eduard
    XIX IMEKO WORLD CONGRESS: FUNDAMENTAL AND APPLIED METROLOGY, PROCEEDINGS, 2009, : 1674 - 1679
  • [25] GOVERNMENTAL PRIMARY STANDARD OF UNIT OF POWER OF ABSORBED DOSE OF PHOTON IONIZING-RADIATION
    BREGADZE, YI
    ISAEV, BM
    TULTAEV, AV
    SILCHENK.AP
    KORSHIKOV, AV
    MEASUREMENT TECHNIQUES, 1973, 16 (03) : 313 - 318
  • [26] GET 38-2024 State primary standard for absorbed dose and absorbed dose rate of photon, electron, and proton radiation and in carbon ion beams and particle quantity, fluence, flux density, and energy in proton and heavy charged particle beams
    Berlyand, Alexander V.
    MEASUREMENT TECHNIQUES, 2025, : 660 - 667
  • [27] The Fricke dosimeter as an absorbed dose to water primary standard for Ir-192 brachytherapy
    El Gamal, Islam
    Cojocaru, Claudiu
    Mainegra-Hing, Ernesto
    McEwen, Malcolm
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (11): : 4481 - 4495
  • [28] Traceability of absorbed dose in photon radiation therapy: from primary standard to patient treatment
    de Carlan, Loic
    Baltes, Didier
    Bordy, Jean-Marc
    Daures, Josiane
    Delaunay, Frank
    Ostrowsky, Aime
    Sorel, Soizic
    ACCREDITATION AND QUALITY ASSURANCE, 2009, 14 (11) : 613 - 618
  • [29] Traceability of absorbed dose in photon radiation therapy: from primary standard to patient treatment
    Loïc de Carlan
    Didier Baltès
    Jean-Marc Bordy
    Josiane Daures
    Frank Delaunay
    Aimé Ostrowsky
    Soizic Sorel
    Accreditation and Quality Assurance, 2009, 14 : 613 - 618
  • [30] RE-ESTABLISHING THE PHOTON ABSORBED DOSE PRIMARY STANDARD ON THE NPL CLINICAL LINAC
    Shipley, D.
    Pearce, J.
    Duane, S.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S38 - S38