Optimization of the Reconstruction Settings for Low-Dose Ultra-High-Resolution Photon-Counting Detector CT of the Lungs

被引:8
|
作者
Graafen, Dirk [1 ]
Halfmann, Moritz C. [1 ,2 ]
Emrich, Tilman [1 ,2 ,3 ]
Yang, Yang [1 ]
Kreuter, Michael [4 ,5 ]
Dueber, Christoph [1 ]
Kloeckner, Roman [6 ]
Mueller, Lukas [1 ]
Jorg, Tobias [1 ]
机构
[1] Johannes Gutenberg Univ Mainz, Univ Med Ctr, Dept Diagnost & Intervent Radiol, D-55131 Mainz, Germany
[2] German Ctr Cardiovasc Res DZHK, Partner Site Rhine Main, D-55131 Mainz, Germany
[3] Med Univ South Carolina, Dept Radiol & Radiol Sci, Div Cardiovasc Imaging, Charleston, SC 29425 USA
[4] Mainz Univ Med Ctr, Mainz Ctr Pulm Med, Dept Pneumol, D-55131 Mainz, Germany
[5] Marienhaus Clin Mainz, Dept Pulm Crit Care & Sleep Med, Mainz, Germany
[6] Univ Hosp Schleswig Holstein, Inst Intervent Radiol, Campus Lubeck, D-23569 Lubeck, Germany
关键词
photon-counting detector CT; lung; slice thickness; quantum iterative reconstruction; ultra-high resolution; IMAGE QUALITY; CHEST-CT; COMPUTED-TOMOGRAPHY; FEASIBILITY;
D O I
10.3390/diagnostics13233522
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Photon-counting detector computed tomography (PCD-CT) yields improved spatial resolution. The combined use of PCD-CT and a modern iterative reconstruction method, known as quantum iterative reconstruction (QIR), has the potential to significantly improve the quality of lung CT images. In this study, we aimed to analyze the impacts of different slice thicknesses and QIR levels on low-dose ultra-high-resolution (UHR) PCD-CT imaging of the lungs. Our study included 51 patients with different lung diseases who underwent unenhanced UHR-PCD-CT scans. Images were reconstructed using three different slice thicknesses (0.2, 0.4, and 1.0 mm) and three QIR levels (2-4). Noise levels were determined in all reconstructions. Three raters evaluated the delineation of anatomical structures and conspicuity of various pulmonary pathologies in the images compared to the clinical reference reconstruction (1.0 mm, QIR-3). The highest QIR level (QIR-4) yielded the best image quality. Reducing the slice thickness to 0.4 mm improved the delineation and conspicuity of pathologies. The 0.2 mm reconstructions exhibited lower image quality due to high image noise. In conclusion, the optimal reconstruction protocol for low-dose UHR-PCD-CT of the lungs includes a slice thickness of 0.4 mm, with the highest QIR level. This optimized protocol might improve the diagnostic accuracy and confidence of lung imaging.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Low-dose lung cancer screening with photon-counting CT: a feasibility study
    Symons, Rolf
    Cork, Tyler E.
    Sahbaee, Pooyan
    Fuld, Matthew K.
    Kappler, Steffen
    Folio, Les R.
    Bluemke, David A.
    Pourmorteza, Amir
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (01): : 202 - 213
  • [42] Unbiased zero-count correction method in low-dose high-resolution photon counting detector CT
    Bushe, Daniel
    Zhang, Ran
    Chen, Guang-Hong
    Li, Ke
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (11):
  • [43] Ultra-high-resolution imaging of the shoulder and pelvis using photon-counting-detector CT: a feasibility study in patients
    Baffour, Francis, I
    Rajendran, Kishore
    Glazebrook, Katrina N.
    Thorne, Jamison E.
    Larson, Nicholas B.
    Leng, Shuai
    McCollough, Cynthia H.
    Fletcher, Joel G.
    EUROPEAN RADIOLOGY, 2022, 32 (10) : 7079 - 7086
  • [44] Extremity radiographs derived from low-dose ultra-high-resolution CT: a phantom study
    Hernandez, Andrew M.
    Bayne, Christopher O.
    Bateni, Cyrus
    Lamba, Ramit
    Boone, John M.
    SKELETAL RADIOLOGY, 2024, 53 (11) : 2491 - 2497
  • [45] Technical note: Exploring the detectability of coronary calcification using ultra-high-resolution photon-counting-detector CT
    Chang, Shaojie
    Ren, Liqiang
    Tang, Shanshan
    Marsh Jr, Jeffrey F.
    Hsieh, Scott
    Mccollough, Cynthia H.
    Leng, Shuai
    MEDICAL PHYSICS, 2023, 50 (11) : 6836 - 6843
  • [46] Ultra-high-resolution imaging of the shoulder and pelvis using photon-counting-detector CT: a feasibility study in patients
    Francis I. Baffour
    Kishore Rajendran
    Katrina N. Glazebrook
    Jamison E. Thorne
    Nicholas B. Larson
    Shuai Leng
    Cynthia H. McCollough
    Joel G. Fletcher
    European Radiology, 2022, 32 : 7079 - 7086
  • [47] Ultra-High-Resolution and K-Edge Imaging of Prosthetic Heart Valves With Spectral Photon-Counting CT A Phantom Study
    Boccalini, Sara
    Mayard, Charles
    Lacombe, Hugo
    Villien, Marjorie
    Si-Mohamed, Salim
    Delahaye, Francois
    Boussel, Loic
    Budde, Ricardo P. J.
    Pozzi, Matteo
    Douek, Philippe
    INVESTIGATIVE RADIOLOGY, 2024, 59 (08) : 589 - 598
  • [48] Pre- and Postoperative Imaging of Cochlear Implantation in Cadaveric Specimens Using Low-Dose Photon-Counting Detector CT
    Spahn, Bjoern
    Miller-Graff, Franz-Tassilo
    Rak, Kristen
    Engert, Jonas
    Voelker, Johannes
    Hackenberg, Stephan
    Hagen, Rudolf
    Neun, Tilmann
    Petritsch, Bernhard
    Bley, Thorsten Alexander
    Grunz, Jan-Peter
    Huflage, Henner
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2025, 46 (02) : 362 - 371
  • [49] CARDIAC THORAX-Ultra-high resolution coronary CTA with photon-counting CT
    Krome, Susanne
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2023, 195 (08): : 669 - 669
  • [50] Low-dose performance of a whole-body research photon-counting CT scanner
    Yu, Zhicong
    Leng, Shuai
    Kappler, Steffen
    Hahn, Katharina
    Li, Zhoubo
    Halaweish, Ahmed F.
    Henning, Andre
    Ritman, Erik L.
    McCollough, Cynthia H.
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783