Optimization of the Reconstruction Settings for Low-Dose Ultra-High-Resolution Photon-Counting Detector CT of the Lungs

被引:8
|
作者
Graafen, Dirk [1 ]
Halfmann, Moritz C. [1 ,2 ]
Emrich, Tilman [1 ,2 ,3 ]
Yang, Yang [1 ]
Kreuter, Michael [4 ,5 ]
Dueber, Christoph [1 ]
Kloeckner, Roman [6 ]
Mueller, Lukas [1 ]
Jorg, Tobias [1 ]
机构
[1] Johannes Gutenberg Univ Mainz, Univ Med Ctr, Dept Diagnost & Intervent Radiol, D-55131 Mainz, Germany
[2] German Ctr Cardiovasc Res DZHK, Partner Site Rhine Main, D-55131 Mainz, Germany
[3] Med Univ South Carolina, Dept Radiol & Radiol Sci, Div Cardiovasc Imaging, Charleston, SC 29425 USA
[4] Mainz Univ Med Ctr, Mainz Ctr Pulm Med, Dept Pneumol, D-55131 Mainz, Germany
[5] Marienhaus Clin Mainz, Dept Pulm Crit Care & Sleep Med, Mainz, Germany
[6] Univ Hosp Schleswig Holstein, Inst Intervent Radiol, Campus Lubeck, D-23569 Lubeck, Germany
关键词
photon-counting detector CT; lung; slice thickness; quantum iterative reconstruction; ultra-high resolution; IMAGE QUALITY; CHEST-CT; COMPUTED-TOMOGRAPHY; FEASIBILITY;
D O I
10.3390/diagnostics13233522
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Photon-counting detector computed tomography (PCD-CT) yields improved spatial resolution. The combined use of PCD-CT and a modern iterative reconstruction method, known as quantum iterative reconstruction (QIR), has the potential to significantly improve the quality of lung CT images. In this study, we aimed to analyze the impacts of different slice thicknesses and QIR levels on low-dose ultra-high-resolution (UHR) PCD-CT imaging of the lungs. Our study included 51 patients with different lung diseases who underwent unenhanced UHR-PCD-CT scans. Images were reconstructed using three different slice thicknesses (0.2, 0.4, and 1.0 mm) and three QIR levels (2-4). Noise levels were determined in all reconstructions. Three raters evaluated the delineation of anatomical structures and conspicuity of various pulmonary pathologies in the images compared to the clinical reference reconstruction (1.0 mm, QIR-3). The highest QIR level (QIR-4) yielded the best image quality. Reducing the slice thickness to 0.4 mm improved the delineation and conspicuity of pathologies. The 0.2 mm reconstructions exhibited lower image quality due to high image noise. In conclusion, the optimal reconstruction protocol for low-dose UHR-PCD-CT of the lungs includes a slice thickness of 0.4 mm, with the highest QIR level. This optimized protocol might improve the diagnostic accuracy and confidence of lung imaging.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Ultra-High-Resolution Temporal Bone Anatomy Using Photon-counting CT: Added Value of Improved Spatial Resolution
    Ansari, Shehbaz
    Jhaveri, Miral D.
    Suthar, Pokhraj Prakashchandra
    DeSanto, Jeffrey
    Gaddikeri, Santhosh
    Vattoth, Surjith
    RADIOGRAPHICS, 2024, 44 (10)
  • [32] Potential of ultra-high-resolution photon-counting CT of bone metastases: initial experiences in breast cancer patients
    E. Wehrse
    S. Sawall
    L. Klein
    P. Glemser
    S. Delorme
    H.-P. Schlemmer
    M. Kachelrieß
    M. Uhrig
    C. H. Ziener
    L. T. Rotkopf
    npj Breast Cancer, 7
  • [33] Neurovascular Imaging with Ultra-High-Resolution Photon-Counting CT: Preliminary Findings on Image-Quality Evaluation
    Toth, Adrienn
    Chetta, Justin A.
    Yazdani, Milad
    Matheus, M. Gisele
    O'Doherty, Jim
    Tipnis, Sameer V.
    Spampinato, M. Vittoria
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2024, 45 (10) : 1450 - 1457
  • [34] Potential of ultra-high-resolution photon-counting CT of bone metastases: initial experiences in breast cancer patients
    Wehrse, E.
    Sawall, S.
    Klein, L.
    Glemser, P.
    Delorme, S.
    Schlemmer, H. -P.
    Kachelriess, M.
    Uhrig, M.
    Ziener, C. H.
    Rotkopf, L. T.
    NPJ BREAST CANCER, 2021, 7 (01)
  • [35] Low-dose CT of the abdomen: Initial experience on a novel photon-counting detector CT and comparison with energy-integrating detector CT
    Decker, Josua A.
    Bette, Stefanie
    Lubina, Nora
    Rippel, Katharina
    Braun, Franziska
    Risch, Franka
    Wollny, Claudia
    Scheurig-Muenkler, Christian
    Kroencke, Thomas J.
    Schwarz, Florian
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 148
  • [36] Ultrahigh-Resolution Photon-Counting Detector CT of the Lungs: Association of Reconstruction Kernel and Slice Thickness With Image Quality
    Milos, Ruxandra-Iulia
    Roehrich, Sebastian
    Prayer, Florian
    Strassl, Andreas
    Beer, Lucian
    Heidinger, Benedikt H.
    Weber, Michael
    Watzenboeck, Martin L.
    Kifjak, Daria
    Tamandl, Dietmar
    Prosch, Helmut
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2023, 220 (05) : 672 - 680
  • [37] Low-dose high-resolution chest CT in adults with cystic fibrosis: intraindividual comparison between photon-counting and energy-integrating detector CT
    Frings, Marko
    Welsner, Matthias
    Mousa, Christin
    Zensen, Sebastian
    Salhoefer, Luca
    Meetschen, Mathias
    Beck, Nikolas
    Bos, Denise
    Westhoelter, Dirk
    Wienker, Johannes
    Taube, Christian
    Umutlu, Lale
    Schaarschmidt, Benedikt M.
    Forsting, Michael
    Haubold, Johannes
    Sutharsan, Sivagurunathan
    Opitz, Marcel
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2024, 8 (01)
  • [38] Spectrum Optimization for Photon-Counting CT with a Silicon Detector
    Schmidt, T.
    Gronberg, F.
    Fan, J.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [39] Photon-counting detector CT: improving interstitial lung disease classification using ultra-high resolution at a fraction of the radiation dose?
    Kishore Rajendran
    Chi Wan Koo
    European Radiology, 2023, 33 : 5526 - 5527
  • [40] Photon-counting detector CT: improving interstitial lung disease classification using ultra-high resolution at a fraction of the radiation dose?
    Rajendran, Kishore
    Koo, Chi Wan
    EUROPEAN RADIOLOGY, 2023, 33 (08) : 5526 - 5527