Computing of Permeability Tensor and Seepage Flow Model of Intact Malan Loess by X-ray Computed Tomography

被引:3
|
作者
Lu, Yangchun [1 ,2 ]
Lu, Yudong [1 ,2 ]
Lu, Ting [1 ,2 ]
Wang, Bo [1 ,2 ]
Zeng, Guanghao [1 ,2 ]
Zhang, Xu [1 ,2 ]
机构
[1] Changan Univ, Sch Water & Environm, Xian 710054, Peoples R China
[2] Changan Univ, Key Lab Subsurface Hydrol & Ecol Effect Arid Reg, Minist Educ, Xian 710054, Peoples R China
基金
中国国家自然科学基金;
关键词
volumetric averaging; CT scan; specific yield; absolute permeability; seepage simulation; POROUS-MEDIUM; EVOLUTION; PLATEAU; FLUID;
D O I
10.3390/w15152851
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Malan loess is an eolian sediment in arid and semi-arid areas. It is of great significance to study the pore structure of Malan loess for its evolution, strength, and mechanical properties. In order to quantitatively characterize the absolute permeability tensor of Malan loess and to simulate the seepage process of Malan loess, this study calculated the specific yield of intact Malan loess with a homemade seepage experimental device and recorded the water flow process on the surface of Malan loess during the seepage process. Modern computed tomography was used to scan the intact Malan loess samples from Jiuzhoutai, Lanzhou (western part of the Loess Plateau, China); the specific yield of the intact loess was used as the parameter value for the threshold segmentation of the scanned image for the 3D reconstruction of the connected pore space, the solver program in AVIZO software was used to solve the absolute permeability tensor of Malan loess using the volume averaging method combined with the CT scan to reconstruct the 3D pore space, and the simulation of the seepage process was carried out. The simulation results showed that Malan loess is a highly anisotropic loess; the absolute permeability in the vertical direction is 9.02 times and 3.86 times higher than the permeability in the horizontal direction. The pore spaces are well connected in the vertical direction (forming a near-vertical arrangement of pipes) and weakly connected in the horizontal direction. In the seepage simulation, it was found that the water flows first along the vertically oriented channels and then fills the horizontally oriented pores; the absolute permeability coefficient was calculated to be 0.3482 & mu;m(2). The indoor seepage experiment was consistent with the simulation experiment, which verifies the reliability of the calculated model.
引用
收藏
页数:20
相关论文
共 50 条
  • [41] X-Ray Luminescence Computed Tomography Via Selective X-Ray Excitation
    Pratx, G.
    Carpenter, C.
    Sun, C.
    Xing, L.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [42] Image Analysis in X-ray Computed Tomography
    Seletchi, Emilia Dana
    Sutac, Victor
    PROCEEDINGS OF THE 1ST INTERNATIONAL CONFERENCE ON VIRTUAL LEARNING: VIRTUAL LEARNING - VIRTUAL REALITY: MODELS & METHODOLOGIES, TECHNOLOGIES, SOFTWARE SOLUTIONS, 2006, : 187 - +
  • [43] Ptychographic X-ray computed tomography at the nanoscale
    Dierolf, Martin
    Menzel, Andreas
    Thibault, Pierre
    Schneider, Philipp
    Kewish, Cameron M.
    Wepf, Roger
    Bunk, Oliver
    Pfeiffer, Franz
    NATURE, 2010, 467 (7314) : 436 - U82
  • [44] X-ray Digital Radiography and Computed Tomography
    Morigi, Maria Pia
    Albertin, Fauzia
    JOURNAL OF IMAGING, 2022, 8 (05)
  • [45] Signal statistics of x-ray computed tomography
    Whiting, BR
    MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING, 2002, 4682 : 53 - 60
  • [46] NOISE LIMITATIONS IN X-RAY COMPUTED TOMOGRAPHY
    TRETIAK, OJ
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1978, 2 (04) : 477 - 480
  • [47] Ptychographic X-ray computed tomography at the nanoscale
    Martin Dierolf
    Andreas Menzel
    Pierre Thibault
    Philipp Schneider
    Cameron M. Kewish
    Roger Wepf
    Oliver Bunk
    Franz Pfeiffer
    Nature, 2010, 467 : 436 - 439
  • [48] APPLIED X-RAY COMPUTED-TOMOGRAPHY
    BUYNAK, CF
    BOSSI, RH
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1995, 99 (1-4): : 772 - 774
  • [49] X-ray computed tomography of polymer composites
    Garcea, S. C.
    Wang, Y.
    Withers, P. J.
    COMPOSITES SCIENCE AND TECHNOLOGY, 2018, 156 : 305 - 319
  • [50] Development of dimensional X-ray computed tomography
    National Metrology Institute of Japan , National Institute of Advanced Industrial Science and Technology , 1-1-1 Umezono, Tsukuba
    Ibaraki
    305-8563, Japan
    Int. J. Autom. Technol., 5 (567-571):