Computing of Permeability Tensor and Seepage Flow Model of Intact Malan Loess by X-ray Computed Tomography

被引:3
|
作者
Lu, Yangchun [1 ,2 ]
Lu, Yudong [1 ,2 ]
Lu, Ting [1 ,2 ]
Wang, Bo [1 ,2 ]
Zeng, Guanghao [1 ,2 ]
Zhang, Xu [1 ,2 ]
机构
[1] Changan Univ, Sch Water & Environm, Xian 710054, Peoples R China
[2] Changan Univ, Key Lab Subsurface Hydrol & Ecol Effect Arid Reg, Minist Educ, Xian 710054, Peoples R China
基金
中国国家自然科学基金;
关键词
volumetric averaging; CT scan; specific yield; absolute permeability; seepage simulation; POROUS-MEDIUM; EVOLUTION; PLATEAU; FLUID;
D O I
10.3390/w15152851
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Malan loess is an eolian sediment in arid and semi-arid areas. It is of great significance to study the pore structure of Malan loess for its evolution, strength, and mechanical properties. In order to quantitatively characterize the absolute permeability tensor of Malan loess and to simulate the seepage process of Malan loess, this study calculated the specific yield of intact Malan loess with a homemade seepage experimental device and recorded the water flow process on the surface of Malan loess during the seepage process. Modern computed tomography was used to scan the intact Malan loess samples from Jiuzhoutai, Lanzhou (western part of the Loess Plateau, China); the specific yield of the intact loess was used as the parameter value for the threshold segmentation of the scanned image for the 3D reconstruction of the connected pore space, the solver program in AVIZO software was used to solve the absolute permeability tensor of Malan loess using the volume averaging method combined with the CT scan to reconstruct the 3D pore space, and the simulation of the seepage process was carried out. The simulation results showed that Malan loess is a highly anisotropic loess; the absolute permeability in the vertical direction is 9.02 times and 3.86 times higher than the permeability in the horizontal direction. The pore spaces are well connected in the vertical direction (forming a near-vertical arrangement of pipes) and weakly connected in the horizontal direction. In the seepage simulation, it was found that the water flows first along the vertically oriented channels and then fills the horizontally oriented pores; the absolute permeability coefficient was calculated to be 0.3482 & mu;m(2). The indoor seepage experiment was consistent with the simulation experiment, which verifies the reliability of the calculated model.
引用
收藏
页数:20
相关论文
共 50 条
  • [21] Dose in x-ray computed tomography
    Kalender, Willi A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (03): : R129 - R150
  • [22] X-ray computed tomography of the heart
    Wijesekera, Nevin T.
    Duncan, Mark K.
    Padley, Simon P. G.
    BRITISH MEDICAL BULLETIN, 2010, 93 (01) : 49 - 67
  • [23] In situ compression and X-ray computed tomography of flow battery electrodes
    Rhodri Jervis
    Matt D.R.Kok
    Tobias P.Neville
    Quentin Meyer
    Leon D.Brown
    Francesco Iacoviello
    Jeff T.Gostick
    Dan J.L.Brett
    Paul R.Shearing
    Journal of Energy Chemistry , 2018, (05) : 1353 - 1361
  • [24] Analysis of blood flow in artificial lung by X-ray computed tomography
    不详
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2005, 28 (09): : 944 - 944
  • [25] Flow properties of sandstone and carbonate rocks by X-ray computed tomography
    Zakirov, T. R.
    Galeev, A. A.
    Korolev, E. A.
    Statsenko, E. O.
    CURRENT SCIENCE, 2016, 110 (11): : 2142 - 2148
  • [26] In situ compression and X-ray computed tomography of flow battery electrodes
    Rhodri Jervis
    Matt DRKok
    Tobias PNeville
    Quentin Meyer
    Leon DBrown
    Francesco Iacoviello
    Jeff TGostick
    Dan JLBrett
    Paul RShearing
    Journal of Energy Chemistry, 2018, 27 (05) : 1353 - 1361
  • [27] In situ compression and X-ray computed tomography of flow battery electrodes
    Jervis, Rhodri
    Kok, Matt D. R.
    Neville, Tobias P.
    Meyer, Quentin
    Brown, Leon D.
    Iacoviello, Francesco
    Gostick, Jeff T.
    Brett, Dan J. L.
    Shearing, Paul R.
    JOURNAL OF ENERGY CHEMISTRY, 2018, 27 (05) : 1353 - 1361
  • [28] X-ray computed tomography using projection X-ray microscope
    Yoshimura, F
    Miyata, C
    Kuzuryu, C
    Hori, A
    Obi, T
    Ohyama, N
    DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 166 - 171
  • [29] Constrained X-ray tensor tomography reconstruction
    Vogel, Jakob
    Schaff, Florian
    Fehringer, Andreas
    Jud, Christoph
    Wieczorek, Matthias
    Pfeiffer, Franz
    Lasser, Tobias
    OPTICS EXPRESS, 2015, 23 (12): : 15134 - 15151
  • [30] Quantitative study on the microstructure of loess soils at micrometer scale via X-ray computed tomography
    Yuan, Weina
    Fan, Wen
    POWDER TECHNOLOGY, 2022, 408