Cyclic response of precast concrete columns connected with cast-in-place UHPC in plastic hinge region

被引:9
|
作者
Zhang, Yangxi [1 ,2 ]
Lei, Heng [1 ]
Dong, ZhiFang [3 ]
Li, Tong [1 ]
Ma, Fudong [4 ]
Liu, Huazheng [5 ]
Deng, Mingke [1 ,2 ]
机构
[1] Xian Univ Architecture & Technol, Sch Civil Engn, Xian 710055, Peoples R China
[2] Minist Educ XAUAT, Key Lab Struct Engn & Earthquake Resistance, Xian 710055, Peoples R China
[3] Shangqiu Normal Univ, Coll Architecture & Civil Engn, Shangqiu 476000, Peoples R China
[4] Shanghai Res Inst Bldg Sci Co Ltd, Shanghai Key Lab Engn Struct Safety, Shanghai 200032, Peoples R China
[5] China Natl Petr Corp EastChina Design Inst Co Ltd, Qingdao 266000, Peoples R China
来源
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
UHPC; Ultra high performance concrete; Cyclic response; Column; Lap length; Flexural capacity; PERFORMANCE; BEHAVIOR; BOND; FRAMES; SHEAR; BARS; RC;
D O I
10.1016/j.jobe.2022.105793
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Ultra high performance concrete (UHPC) is a promising material for lap splice connection of steel bars in reinforced concrete (RC) precast structures given its high compressive strength, its high toughness, and its high bond strength with steel bars. This paper focuses on the cyclic response of bottom frame columns connected by UHPC in the plastic hinge region. The effect of lap length of longitudinal bars in UHPC (6d, 8d and 12d, d = diameter of longitudinal bar), axial load ratio and stirrup ratio of the UHPC connection region on the global response of the columns were presented and analyzed, and a cast-in-site RC column was prepared for comparison. The behavior of the UHPC connected columns was flexural dominated, but columns with 6d and 8d lap length failed due to the gradual bonding degradation between UHPC and longitudinal bars, and the column with 12d lap length failed due to UHPC crushing. It was demonstrated that a 8d lap length could achieve equivalent lateral bearing capacity and ductility to the control RC column, but the lap length should be greater than 8d when applying UHPC connection technology in seismic regions to ensure the energy dissipation. Column with lower axial load ratio (0.17) exhibited lower ductility because shear sliding occurred between the interface of UHPC and footing at the postpeak stage. The UHPC connected specimens exhibited higher resilience and better damage resistance in earthquake because the ratios of the residual displacements to the corresponding peak displacements were between 17 and 39%. Besides, a flexural capacity model for the columns was developed and the results predicted by the model agreed well with the experimental results.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Comparative study on the seismic behavior of precast concrete-encased CFST column to precast and cast-in-place beam joints
    Zhu, Yazhi
    Wang, Wei
    Lin, Ronghui
    JOURNAL OF BUILDING ENGINEERING, 2025, 104
  • [42] Comparative Study of Seismic Behavior between Monolithic Precast Concrete Structure and Cast-in-Place Structure
    Qin, Chao-gang
    Bai, Guo-liang
    Xu, Ya-zhou
    Su, Ning-fen
    Wu, Tao
    SHOCK AND VIBRATION, 2018, 2018
  • [43] Comparison of precast and cast-in-place concrete pavements responses under heavy vehicle simulator loads
    Kohler, E.
    Harvey, J.
    Du Plessis, L.
    Motumah, L.
    BEARING CAPACITY OF ROADS, RAILWAYS AND AIRFIELDS, VOLS 1 AND 2, 2009, : 1415 - +
  • [44] Experimental evaluation of flexural behavior of composite beams with cast-in-place concrete slabs on precast prestressed concrete decks
    Hou, Hetao
    Liu, Xiang
    Qu, Bing
    Ma, Tianxiang
    Liu, Haining
    Feng, Mingyuan
    Zhang, Bo
    ENGINEERING STRUCTURES, 2016, 126 : 405 - 416
  • [45] Parameter identification of hysteretic model of UHPC-connected precast segmental columns under cyclic loading
    Zhu, Guoqiang
    Zhou, Mi
    Song, Jianwei
    Wang, Jiaxin
    Zhao, Xiaonan
    STRUCTURES, 2023, 58
  • [46] Field Test Research on Embankment Supported by Plastic Tube Cast-in-place Concrete Piles
    Chen Y.
    Qi C.
    Xu H.
    Ng C.W.W.
    Geotechnical and Geological Engineering, 2013, 31 (4) : 1359 - 1368
  • [47] Comparative study on the seismic performance of subway stations using reinforced concrete cast-in-place columns and truncated columns
    Ma, Chao
    Zhao, Yuanqi
    Dong, Huihui
    Lu, Dechun
    Du, Xiuli
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2023, 169
  • [48] Strengthening of Unreinforced Brick Masonry Panel Using Cast-in-Place and Precast Textile-Reinforced Concrete
    Gopinath, Smitha
    Madheswaran, C. K.
    Prabhakar, J.
    Devi, K. G. Thivya
    Anuhya, C. Lakshmi
    JOURNAL OF EARTHQUAKE ENGINEERING, 2022, 26 (03) : 1209 - 1227
  • [49] Experimental analysis of the shear resistance of precast concrete T-beams with a top cast-in-place slab
    Rueda-Garcia, Lisbel
    Bonet, Jose L.
    Miguel, Pedro
    Fernandez-Prada, Miguel Angel
    ENGINEERING STRUCTURES, 2023, 291
  • [50] A comparative experimental study on the mechanical properties of cast-in-place and precast concrete-frozen soil interfaces
    Zheng, Guo
    Xue, Ke
    Hu, Jian
    Zhang, Mingli
    Li, Desheng
    Yang, Ping
    Xie, Jun
    GEOMECHANICS AND ENGINEERING, 2024, 36 (02) : 145 - 156