Cyclic response of precast concrete columns connected with cast-in-place UHPC in plastic hinge region

被引:9
|
作者
Zhang, Yangxi [1 ,2 ]
Lei, Heng [1 ]
Dong, ZhiFang [3 ]
Li, Tong [1 ]
Ma, Fudong [4 ]
Liu, Huazheng [5 ]
Deng, Mingke [1 ,2 ]
机构
[1] Xian Univ Architecture & Technol, Sch Civil Engn, Xian 710055, Peoples R China
[2] Minist Educ XAUAT, Key Lab Struct Engn & Earthquake Resistance, Xian 710055, Peoples R China
[3] Shangqiu Normal Univ, Coll Architecture & Civil Engn, Shangqiu 476000, Peoples R China
[4] Shanghai Res Inst Bldg Sci Co Ltd, Shanghai Key Lab Engn Struct Safety, Shanghai 200032, Peoples R China
[5] China Natl Petr Corp EastChina Design Inst Co Ltd, Qingdao 266000, Peoples R China
来源
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
UHPC; Ultra high performance concrete; Cyclic response; Column; Lap length; Flexural capacity; PERFORMANCE; BEHAVIOR; BOND; FRAMES; SHEAR; BARS; RC;
D O I
10.1016/j.jobe.2022.105793
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Ultra high performance concrete (UHPC) is a promising material for lap splice connection of steel bars in reinforced concrete (RC) precast structures given its high compressive strength, its high toughness, and its high bond strength with steel bars. This paper focuses on the cyclic response of bottom frame columns connected by UHPC in the plastic hinge region. The effect of lap length of longitudinal bars in UHPC (6d, 8d and 12d, d = diameter of longitudinal bar), axial load ratio and stirrup ratio of the UHPC connection region on the global response of the columns were presented and analyzed, and a cast-in-site RC column was prepared for comparison. The behavior of the UHPC connected columns was flexural dominated, but columns with 6d and 8d lap length failed due to the gradual bonding degradation between UHPC and longitudinal bars, and the column with 12d lap length failed due to UHPC crushing. It was demonstrated that a 8d lap length could achieve equivalent lateral bearing capacity and ductility to the control RC column, but the lap length should be greater than 8d when applying UHPC connection technology in seismic regions to ensure the energy dissipation. Column with lower axial load ratio (0.17) exhibited lower ductility because shear sliding occurred between the interface of UHPC and footing at the postpeak stage. The UHPC connected specimens exhibited higher resilience and better damage resistance in earthquake because the ratios of the residual displacements to the corresponding peak displacements were between 17 and 39%. Besides, a flexural capacity model for the columns was developed and the results predicted by the model agreed well with the experimental results.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Cyclic Loading Test for Cast-in-Place Concrete-Filled Hollow Precast Concrete Columns
    Kim, Chang-Soo
    Lim, Woo-Young
    Park, Hong-Gun
    Oh, Jung-Keun
    ACI STRUCTURAL JOURNAL, 2016, 113 (02) : 205 - 215
  • [2] Cyclic loading tests and analyses of posttensioned concrete bridge columns combining cast-in-place and precast segments
    Zhang, Yuye
    Wu, Gang
    Dias-da-Costa, D.
    BULLETIN OF EARTHQUAKE ENGINEERING, 2019, 17 (11) : 6141 - 6163
  • [3] Cyclic loading tests and analyses of posttensioned concrete bridge columns combining cast-in-place and precast segments
    Yuye Zhang
    Gang Wu
    D. Dias-da-Costa
    Bulletin of Earthquake Engineering, 2019, 17 : 6141 - 6163
  • [4] Seismic performance of precast concrete columns with prefabricated UHPC jackets in plastic hinge zone
    Guan, Dongzhi
    Chen, Zixuan
    Liu, Jiabin
    Lin, Zhiyi
    Guo, Zhengxing
    ENGINEERING STRUCTURES, 2021, 245
  • [5] Precast Concrete Modules combined with Cast-in-place Concrete
    不详
    BAUINGENIEUR, 2013, 88 : A13 - A13
  • [6] Bond Characterization and Interfacial Coefficients at Precast UHPC and Cast-in-Place UHPC Interface
    Semendary, Ali A.
    Svecova, Dagmar
    JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2021, 33 (07)
  • [7] Research on Quasi-Static Test for Cast-in-Place UHPC Joints in Precast Segmental Pier and Heights of Cast-in-Place Joints
    Zheng, Gang
    Chen, Liujian
    Gao, Liqiang
    Bridge Construction, 2024, 54 (06) : 56 - 63
  • [8] Effect of Interfacial Treatment on Shear Properties of Precast UHPC and Cast-in-Place NC
    Cheng W.
    Geng J.
    Liu G.
    Liu C.
    Zheng Z.
    Jianzhu Cailiao Xuebao/Journal of Building Materials, 2024, 27 (01): : 76 - 83
  • [9] CYCLIC RESPONSE OF FIBROUS CAST-IN-PLACE CONNECTIONS IN PRECAST BEAM-COLUMN SUBASSEMBLAGES
    SOUBRA, KS
    WIGHT, JK
    NAAMAN, AE
    ACI STRUCTURAL JOURNAL, 1993, 90 (03) : 316 - 323
  • [10] Three-Dimensional Fiber-Based Models of Precast and Cast-in-Place Reinforced Concrete Columns
    Al-Jelawy, Haider M.
    Mackie, Kevin R.
    JOURNAL OF STRUCTURAL ENGINEERING, 2022, 148 (03)