Synchrotron Radiation Refraction-Contrast Computed Tomography Based on X-ray Dark-Field Imaging Optics of Pulmonary Malignancy: Comparison with Pathologic Examination

被引:0
|
作者
Yi, Eunjue [1 ]
Sunaguchi, Naoki [2 ,3 ]
Lee, Jeong Hyeon [4 ]
Seo, Seung-Jun [5 ]
Lee, Sungho [1 ]
Shimao, Daisuke [6 ]
Ando, Masami [7 ]
机构
[1] Korea Univ, Anam Hosp, Dept Thorac & Cardiovasc Surg, Seoul 02841, South Korea
[2] Nagoya Univ, Dept Radiol, Nagoya 4618673, Japan
[3] Nagoya Univ, Grad Sch Med, Med Lab Sci, Nagoya 4618673, Japan
[4] Korea Univ, Anam Hosp, Dept Pathol, Seoul 02841, South Korea
[5] Daegu Catholic Univ, Med Ctr, Dept Expt Anim Facil, Daegu 42472, South Korea
[6] Butsuryo Coll Osaka, Fac Hlth Sci, Osaka 5938328, Japan
[7] Inst Mat Struct Sci, Photon Factory, High Energy Accelerator Res Org, Tsukuba 3003256, Japan
基金
新加坡国家研究基金会;
关键词
refraction contrast; lung cancer; diagnosis; GROUND-GLASS OPACITY; MINIMALLY INVASIVE ADENOCARCINOMA; LUNG ADENOCARCINOMA; IN-SITU; CLASSIFICATION; MANAGEMENT; PROGNOSIS; DIAGNOSIS; RESECTION; SIZE;
D O I
10.3390/cancers16040806
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Simple Summary The imaging method called refraction-contrast computed tomography using synchrotron radiation can achieve detailed images almost similar to those from a microscope. This study examined its ability to recognize lung cancer. We took pictures of lung cancer samples in Japan using this imaging method. These pictures showed the insides of the samples precisely, making it easy to distinguish healthy tissue from cancerous spots. They even allowed us to tell the difference between a main lung cancer and one that started somewhere else, like the colon. Fundamentally, this method could be a way to check for lung cancer without cutting into tissue. However, before doctors can use it, the machines involved need some major changes.Abstract Refraction-contrast computed tomography based on X-ray dark-field imaging (XDFI) using synchrotron radiation (SR) has shown superior resolution compared to conventional absorption-based methods and is often comparable to pathologic examination under light microscopy. This study aimed to investigate the potential of the XDFI technique for clinical application in lung cancer diagnosis. Two types of lung specimens, primary and secondary malignancies, were investigated using an XDFI optic system at beamline BL14B of the High-Energy Accelerator Research Organization Photon Factory, Tsukuba, Japan. Three-dimensional reconstruction and segmentation were performed on each specimen. Refraction-contrast computed tomographic images were compared with those obtained from pathological examinations. Pulmonary microstructures including arterioles, venules, bronchioles, alveolar sacs, and interalveolar septa were identified in SR images. Malignant lesions could be distinguished from the borders of normal structures. The lepidic pattern was defined as the invasive component of the same primary lung adenocarcinoma. The SR images of secondary lung adenocarcinomas of colorectal origin were distinct from those of primary lung adenocarcinomas. Refraction-contrast images based on XDFI optics of lung tissues correlated well with those of pathological examinations under light microscopy. This imaging method may have the potential for use in lung cancer diagnosis without tissue damage. Considerable equipment modifications are crucial before implementing them from the lab to the hospital in the near future.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] State of the Art of X-ray Speckle-Based Phase-Contrast and Dark-Field Imaging
    Zdora, Marie-Christine
    JOURNAL OF IMAGING, 2018, 4 (05)
  • [42] X-ray dark-field and phase-contrast imaging using a grating interferometer
    Pfeiffer, F.
    Bech, M.
    Bunk, O.
    Donath, T.
    Henrich, B.
    Kraft, P.
    David, C.
    JOURNAL OF APPLIED PHYSICS, 2009, 105 (10)
  • [43] X-ray dark-field and phase-contrast imaging using a grating interferometer
    Pfeiffer, F.
    Bech, M.
    Bunk, O.
    Donath, T.
    Henrich, B.
    Kraft, P.
    David, C.
    Journal of Applied Physics, 2009, 105 (10):
  • [44] Review and experimental verification of x-ray dark-field signal interpretations with respect to quantitative isotropic and anisotropic dark-field computed tomography
    Graetz, J.
    Balles, A.
    Hanke, R.
    Zabler, S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (23):
  • [45] Clinical step onward with X-ray dark-field imaging and perspective view of medical applications of synchrotron radiation in Japan
    Ando, M
    Hashimoto, E
    Hashizume, H
    Hyodo, K
    Inoue, H
    Kunisada, T
    Maksimenko, A
    Mori, K
    Rubenstein, E
    Roberson, J
    Shimao, D
    Sugiyama, H
    Takeda, K
    Toyofuku, F
    Ueno, E
    Umetani, K
    Wada, H
    Pattanasiriwisawa, W
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 548 (1-2): : 1 - 16
  • [46] Visualization of Arabidopsis root system architecture in 3D by refraction-contrast X-ray micro-computed tomography
    Kurogane, Tomofumi
    Tamaoki, Daisuke
    Yano, Sachiko
    Tanigaki, Fumiaki
    Shimazu, Toru
    Kasahara, Haruo
    Yamauchi, Daisuke
    Uesugi, Kentaro
    Hoshino, Masato
    Kamisaka, Seiichiro
    Mineyuki, Yoshinobu
    Karahara, Ichirou
    MICROSCOPY, 2021, 70 (06) : 536 - 544
  • [47] In-vivo X-ray dark-field computed tomography for the detection of radiation-induced lung damage in mice
    Burkhardt, Rico
    Gora, Thomas
    Fingerle, Alexander A.
    Sauter, Andreas P.
    Meurer, Felix
    Gassert, Florian T.
    Dobiasch, Sophie
    Schilling, Daniela
    Feuchtinger, Annette
    Walch, Axel K.
    Multhoff, Gabriele
    Herzen, Julia
    Noel, Peter B.
    Rummeny, Ernst J.
    Combs, Stephanie E.
    Schmid, Thomas E.
    Pfeiffer, Franz
    Wilkens, Jan J.
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2021, 20 : 11 - 16
  • [48] Speckle-Based X-Ray Dark-Field Tomography of an Attenuating Object
    Alloo, S. J.
    Paganin, D. M.
    Morgan, K. S.
    Kitchen, M. J.
    Stevenson, A. W.
    Mayo, S. C.
    Li, H. T.
    Kennedy, B. M.
    Maksimenko, A.
    Bowden, J.
    Pavlov, K. M.
    DEVELOPMENTS IN X-RAY TOMOGRAPHY XIII, 2021, 11840
  • [49] Synchrotron radiation used fluorescent X-ray computed tomography as a novel molecular imaging
    Sunaguchi, Naoki
    Huo, Qing Kai
    Nasukawa, Seita
    Maikusa, Norihide
    Fukami, Tadanori
    Yuasa, Tetsuya
    Takeda, Tohoru
    Wu, Jin
    Thet-Thet-Lwin
    Hyodo, Kazuyuki
    Dilmanian, F. Avraham
    Akatsuka, Takao
    PROCEEDINGS OF THE SEVENTH IASTED INTERNATIONAL CONFERENCE ON VISUALIZATION, IMAGING, AND IMAGE PROCESSING, 2007, : 94 - +
  • [50] Improvement of imaging speed in fluorescent X-ray computed tomography using synchrotron radiation
    Hasegawa, Yasuhiro
    Yu, Quanwen
    Noto, Daisuke
    Takeda, Tohoru
    Hyodo, Kazuyuki
    Yashiro, Toru
    Yuasa, Tetsuya
    Hiranaka, Yukio
    Itai, Yuji
    Akatsuka, Takao
    Hasegawa, Y., 1600, John Wiley and Sons Inc. (33): : 1 - 11