A low-noise current-sensitive preamplifier VIEC based on a charge-sensitive preamplifier

被引:0
|
作者
Kanno, Ikuo [1 ]
Nishikawa, Junichiro [1 ]
Onabe, Hideaki [2 ]
机构
[1] Kyoto Univ, Grad Sch Engn, Dept Nucl Engn, Nishikyo, Kyoto 6158530, Japan
[2] Raytech Corp, Utsunomiya, Tochigi 3210904, Japan
关键词
Current preamplifier; Charge preamplifier; Low noise; Dynamic range; X-ray computed tomography;
D O I
10.1016/j.nima.2022.167789
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A low-noise current-sensitive preamplifier VIEC has been developed based on the circuitry of a charge-sensitive preamplifier. In this paper, the dynamic ranges of the VIEC and a conventional current-sensitive preamplifier are measured and compared. A method to increase the dynamic range of the VIEC is described. Using the VIEC with enhanced dynamic range, a computed tomography measurement is performed for a strongly attenuating phantom comprising a 10-cm-diameter acrylic cylinder with a 3-cm-diameter iron rod in the center.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] A MONOLITHIC RADIATION-TOLERANT CHARGE-SENSITIVE PREAMPLIFIER
    BUTTLER, W
    CITTERIO, M
    LUTZ, G
    MANFREDI, PF
    RE, V
    SPEZIALI, V
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 292 (02): : 435 - 438
  • [22] Miniature charge-sensitive preamplifier for compound semiconductor detector
    Liu, Zhengshan
    Zhang, Zhiyong
    Deng, Changming
    Cheng, Chang
    Su, Xiaohui
    Li, Mei
    Hedianzixue Yu Tance Jishu/Nuclear Electronics & Detection Technology, 17 (06): : 465 - 468
  • [23] A low power, charge-sensitive preamplifier integrated with a silicon nanowire biosensor
    Bhattacharjee, Abhiroop
    Kandpal, Kavindra
    2021 IEEE LATIN AMERICA ELECTRON DEVICES CONFERENCE (LAEDC), 2021,
  • [24] Integrated low-noise low-power fast charge-sensitive preamplifier for avalanche photodiodes in JFET-CMOS technology
    Pichler, BJ
    Pimpl, W
    Buttler, W
    Kotoulas, L
    Böning, G
    Rafecas, M
    Lorenz, E
    Ziegler, SI
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (06) : 2370 - 2374
  • [25] The application of Multisim software to the analyzing of the charge-sensitive preamplifier
    Zhou, Chao
    Yang, Bin-Hua
    Zhao, Xiu-Liang
    Yin, Chen-Yan
    Hedianzixue Yu Tance Jishu/Nuclear Electronics and Detection Technology, 2007, 27 (03): : 502 - 506
  • [26] DETECTION UNIT WITH CORRELATION CHARGE-SENSITIVE PREAMPLIFIER.
    Pod'yachev, V.N.
    Instruments and experimental techniques New York, 1980, 23 (4 pt 2): : 944 - 947
  • [27] NUCLEAR ELECTRONICS - CHARGE-SENSITIVE PREAMPLIFIER FOR SEMICONDUCTOR DETECTORS
    STANEK, FW
    KERNTECHNIK, 1969, 11 (05) : 286 - &
  • [28] Fast charge-sensitive preamplifier for pure CsI crystals
    Martin, J. -P.
    Starinski, N. A.
    Taras, P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 778 : 120 - 125
  • [29] FAST LOW-NOISE CHARGE PREAMPLIFIER
    KARLOVAC, N
    MAYHUGH, TL
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1977, 24 (01) : 327 - 334
  • [30] The design of charge-sensitive preamplifier with differential JFET input
    Xiao Hai-jun
    Zhang Liu-qiang
    Xiao Sha-li
    Li Xian-cang
    Huang Zhen-hua
    INTERNATIONAL SYMPOSIUM ON PHOTOELECTRONIC DETECTION AND IMAGING 2013: LASER SENSING AND IMAGING AND APPLICATIONS, 2013, 8905