Investigation of an ejector-cascaded vapor compression-absorption refrigeration cycle powered by linear fresnel and organic rankine cycle

被引:9
|
作者
Askari, Ighball Baniasad [1 ]
Ghazizade-Ahsaee, Hossein [2 ]
Kasaeian, Alibakhsh [3 ]
机构
[1] Univ Zabol, Fac Engn, Dept Mech Engn, Zabol, Iran
[2] Tech & Vocat Univ TVU, Dept Mech Engn, Tehran, Iran
[3] Univ Tehran, Fac New Sci & Technol, Dept Renewable Energies & Environm, Tehran, Iran
关键词
Cascade refrigeration; Food storage; Solar field; Thermal energy storage; Thermoelectric; Ejector; THERMOELECTRIC GENERATOR; COOLING SYSTEM; PERFORMANCE-CHARACTERISTICS; THERMOECONOMIC ANALYSIS; FINANCIAL EVALUATION; BIOENERGY INDUSTRY; ECONOMIC-ANALYSIS; EXERGY ANALYSIS; SOLAR; ENERGY;
D O I
10.1007/s10668-022-02442-z
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The low-temperature cooling through the cascade compression-absorption refrigeration system with the solar thermal source is a promising technology to be used in food storage applications. This paper studies an integrated organic rankine cycle (ORC, toluene)/ejector-cascade compression (R1234yf)-absorption (LiBr-H2O) refrigeration system/thermo-electric generator (TEG) powered by the linear Fresnel solar collectors. The power generation of the ORC and TEGs was assumed to supply the electricity consumption of the system. A thermo-economic analysis was performed to determine the influence of different parameters on the system performance, heat transfer areas, solar field, and thermal energy storage (TES) system optimum sizes, and the levelized cost of the cooling energy (COC). The calculations were conducted for three locations to specify the influence of solar radiation level on the system sizes and COC. Based on the results, the energy and exergy efficiencies (eta(I) and eta(II)) vary from 38 to 50% and from 3.6 to 4.6%, respectively. Although the capital investment and complexity are the practical limitations, the cascade cycle coefficient of performance and the system overall efficiency improvement were obtained as 27.02% and 51.19%% over the cycle without ejector and TEG reported in the previous research studies. Also, for three locations with highest, medium, and lowest solar radiation levels, the minimum COC (and annual solar share) was obtained as 0.049-0.062 $/kWh (36-74%), 0.068-0.079 $/kWh (32-55%), and 0.145-0.158 $/kWh (18-27%), respectively, for different TES capacities and capital costs. Moreover, the TEG modules are capable of supplying nearly 27% of the total power consumption of the system. For two regions located in Iran and United Arab Emirates, the COC of the fuel-based system becomes equal to that of the solar-based system if the conventional fuel prices in United Arab Emirates and Iran are increased by 202% and 316%, respectively.
引用
收藏
页码:9439 / 9484
页数:46
相关论文
共 50 条
  • [1] Investigation of an ejector-cascaded vapor compression–absorption refrigeration cycle powered by linear fresnel and organic rankine cycle
    Ighball Baniasad Askari
    Hossein Ghazizade-Ahsaee
    Alibakhsh Kasaeian
    Environment, Development and Sustainability, 2023, 25 : 9439 - 9484
  • [2] Optimization of waste heat based organic Rankine cycle powered cascaded vapor compression-absorption refrigeration system
    Patel, Bhavesh
    Desai, Nishith B.
    Kachhwaha, Surendra Singh
    ENERGY CONVERSION AND MANAGEMENT, 2017, 154 : 576 - 590
  • [3] Thermo-economic analysis of solar-biomass organic Rankine cycle powered cascaded vapor compression-absorption system
    Patel, Bhavesh
    Desai, Nishith B.
    Kachhwaha, Surendra Singh
    SOLAR ENERGY, 2017, 157 : 920 - 933
  • [4] Thermo-economic analysis of a novel organic Rankine cycle integrated cascaded vapor compression-absorption system
    Patel, Bhavesh
    Desai, Nishith B.
    Kachhwaha, Surendra Singh
    Jain, Vaibhav
    Hadia, Nanji
    JOURNAL OF CLEANER PRODUCTION, 2017, 154 : 26 - 40
  • [5] Thermal analysis of solar energy based organic Rankine cycle cascaded with vapor compression refrigeration cycle
    Qureshi, Mohammad Faizan
    Chandio, Mohammad Waqas
    Memon, Abdul Aleem
    Kumar, Laveet
    Awad, Mohamed M.
    ENERGY NEXUS, 2024, 14
  • [6] Thermo-economic and environmental evaluation of a novel SOFC based trigeneration system using organic Rankine cycle and cascaded vapor compression-absorption refrigeration system
    Khan, Yunis
    Singh, Pawan Kumar
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2025, 57
  • [7] Energy and Exergy Analysis of Solar Organic Rankine Cycle Coupled with Vapor Compression Refrigeration Cycle
    Kim, Man-Hoe
    ENERGIES, 2022, 15 (15)
  • [8] Performance analysis of a combined organic Rankine cycle and vapor compression cycle for power and refrigeration cogeneration
    Kim, Kyoung Hoon
    Perez-Blanco, Horacio
    APPLIED THERMAL ENGINEERING, 2015, 91 : 964 - 974
  • [9] Thermodynamic performance analysis of a vapor compression-absorption cascaded refrigeration system
    Jain, Vaibhav
    Kachhwaha, S. S.
    Sachdeva, Gulshan
    ENERGY CONVERSION AND MANAGEMENT, 2013, 75 : 685 - 700
  • [10] Investigation of an ejector powered double-effect absorption/recompression refrigeration cycle
    Sioud, Doniazed
    Bourouis, Mahmoud
    Bellagi, Ahmed
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 99 : 453 - 468