FLASH Radiotherapy and the Use of Radiation Dosimeters

被引:23
|
作者
Siddique, Sarkar [1 ]
Ruda, Harry E. [2 ,3 ]
Chow, James [4 ,5 ]
机构
[1] Toronto Metropolitan Univ, Dept Phys, Toronto, ON M5B 2K3, Canada
[2] Univ Toronto, Fac Appl Sci & Engn, Ctr Adv Nanotechnol, Toronto, ON M5S 3E4, Canada
[3] Univ Toronto, Dept Mat Sci & Engn, Toronto, ON M5S 3E4, Canada
[4] Univ Hlth Network, Princess Margaret Canc Ctr, Radiat Med Program, Toronto, ON M5G 1X6, Canada
[5] Univ Toronto, Dept Radiat Oncol, Toronto, ON M5T 1P5, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
FLASH radiotherapy; ultra-high dose rate radiotherapy; detectors; dosimetry; CHAMBER;
D O I
10.3390/cancers15153883
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Simple Summary: FLASH radiotherapy (RT) delivering ultra-high dose rate radiation can reduce normal tissue toxicity while effectively treating tumors. However, implementing FLASH RT in clinical settings faces challenges like limited depth penetration and complex treatment planning. Monte Carlo simulation is a valuable tool to optimize FLASH RT. Radiation detectors, including diamond detectors like microDiamond and ionization chambers, play a crucial role in accurately measuring dose delivery. Moreover, optically stimulated luminescence dosimeters and radiochromic films are used for validation. Advancements are being made to improve detector accuracy in FLASH RT. Further research is needed to refine treatment planning and detector performance for widespread FLASH RT implementation, which can potentially revolutionize cancer treatment. Radiotherapy (RT) using ultra-high dose rate (UHDR) radiation, known as FLASH RT, has shown promising results in reducing normal tissue toxicity while maintaining tumor control. However, implementing FLASH RT in clinical settings presents technical challenges, including limited depth penetration and complex treatment planning. Monte Carlo (MC) simulation is a valuable tool for dose calculation in RT and has been investigated for optimizing FLASH RT. Various MC codes, such as EGSnrc, DOSXYZnrc, and Geant4, have been used to simulate dose distributions and optimize treatment plans. Accurate dosimetry is essential for FLASH RT, and radiation detectors play a crucial role in measuring dose delivery. Solid-state detectors, including diamond detectors such as microDiamond, have demonstrated linear responses and good agreement with reference detectors in UHDR and ultra-high dose per pulse (UHDPP) ranges. Ionization chambers are commonly used for dose measurement, and advancements have been made to address their response nonlinearities at UHDPP. Studies have proposed new calculation methods and empirical models for ion recombination in ionization chambers to improve their accuracy in FLASH RT. Additionally, strip-segmented ionization chamber arrays have shown potential for the experimental measurement of dose rate distribution in proton pencil beam scanning. Radiochromic films, such as Gafchromic (TM) EBT3, have been used for absolute dose measurement and to validateMCsimulation results in high-energy X-rays, triggering the FLASH effect. These films have been utilized to characterize ionization chambers and measure off-axis and depth dose distributions in FLASH RT. In conclusion, MC simulation provides accurate dose calculation and optimization for FLASH RT, while radiation detectors, including diamond detectors, ionization chambers, and radiochromic films, offer valuable tools for dosimetry in UHDR environments. Further research is needed to refine treatment planning techniques and improve detector performance to facilitate the widespread implementation of FLASH RT, potentially revolutionizing cancer treatment.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Multiphase 3D dosimeters for radiotherapy
    Kozicki, Marek
    Maras, Piotr
    Jaszczak-Kuligowska, Malwina
    13TH INTERNATIONAL CONFERENCE ON 3D DOSIMETRY, IC3DDOSE 2024, 2024, 2799
  • [42] Alanine dosimeters for LET measurement in proton radiotherapy
    Michalec, Barbara
    Stolarczyk, Liliana
    Bassler, Niels
    Rydygier, Marzena
    Spaleniak, Anna
    Kopec, Renata
    RADIATION MEASUREMENTS, 2024, 175
  • [43] A review of diamond dosimeters in advanced radiotherapy techniques
    Angelou, Christina
    Patallo, Ileana Silvestre
    Doherty, Daniel
    Romano, Francesco
    Schettino, Giuseppe
    MEDICAL PHYSICS, 2024,
  • [44] Fiber-based dosimeters for applications in radiotherapy
    Darafsheh, Arash
    FIBER OPTIC SENSORS AND APPLICATIONS XVI, 2019, 11000
  • [45] Radiotherapy Using High-Intensity Pulsed Radiation Beams (FLASH): A Radiation-Chemical Perspective
    Wardman, Peter
    RADIATION RESEARCH, 2020, 194 (06) : 607 - 617
  • [46] FLASH Radiotherapy: A Clarification
    Symonds, P.
    Jones, G. D. D.
    CLINICAL ONCOLOGY, 2020, 32 (07) : 479 - 479
  • [47] Democratizing FLASH Radiotherapy
    Moreau, Michele
    Mao, Serena
    Ngwa, Uriel
    Yasmin-Karim, Sayeda
    China, Debarghya
    Hooshangnejad, Hamed
    Sforza, Daniel
    Ding, Kai
    Li, Heng
    Rezaee, Mohammad
    Narang, Amol K.
    Ngwa, Wilfred
    SEMINARS IN RADIATION ONCOLOGY, 2024, 34 (03) : 344 - 350
  • [48] ENVIRONMENTAL RADIATION MONITORING WITH THERMOLUMINESCENT DOSIMETERS
    HOY, JE
    HEALTH PHYSICS, 1971, 21 (06): : 860 - +
  • [49] Radiation-induced free radicals from different milk powders and its possible use as radiation dosimeters
    Atia, Ahmed Ibrahim
    Gafar, Sameh Mohammed
    RADIOCHIMICA ACTA, 2020, 108 (04) : 321 - 325
  • [50] Implantable Wireless Dosimeters for Radiation Oncology
    Maleki, T.
    Son, C.
    Ziaie, B.
    2009 IEEE INTERNATIONAL ELECTRON DEVICES MEETING, 2009, : 547 - +