Pectus excavatum in motion: dynamic evaluation using real-time MRI

被引:5
|
作者
Graefe, Daniel [1 ]
Lacher, Martin [2 ]
Martynov, Illya [2 ]
Hirsch, Franz Wolfgang [1 ]
Voit, Dirk [3 ]
Frahm, Jens [3 ]
Busse, Harald [4 ]
Sesia, Sergio Bruno [5 ]
Kraemer, Sebastian [6 ]
Zimmermann, Peter [2 ]
机构
[1] Univ Hosp, Dept Pediat Radiol, Leipzig, Germany
[2] Univ Hosp, Dept Pediat Surg, Leipzig, Germany
[3] Max Planck Inst Biophys Chem, Biomed NMR, Gottingen, Germany
[4] Univ Hosp, Dept Diagnost & Intervent Radiol, Leipzig, Germany
[5] Bern Univ Hosp, Div Gen Thorac Surg, Bern, Switzerland
[6] Univ Hosp, Dept Visceral Transplant Thorac & Vasc Surg, Div Gen Thorac Surg, Leipzig, Germany
关键词
Funnel chest; Magnetic resonance imaging; Thoracic wall; PREOPERATIVE EVALUATION; COMPUTED-TOMOGRAPHY; INDEX;
D O I
10.1007/s00330-022-09197-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives The breathing phase for the determination of thoracic indices in patients with pectus excavatum is not standardized. The aim of this study was to identify the best period for reliable assessments of morphologic indices by dynamic observations of the chest wall using real-time MRI. Methods In this prospective study, patients with pectus excavatum underwent morphologic evaluation by real-time MRI at 3 T between January 2020 and June 2021. The Haller index (HI), correction index (CI), modified asymmetry index (AI), and modified eccentricity index (EI) were determined during free, quiet, and forced breathing respectively. Breathing-related differences in the thoracic indices were analyzed with the Wilcoxon signed-rank test. Motion of the anterior chest wall was analyzed as well. Results A total of 56 patients (11 females and 45 males, median age 15.4 years, interquartile range 14.3-16.9) were included. In quiet expiration, the median HI in the cohort equaled 5.7 (4.5-7.2). The median absolute differences (Delta) in the thoracic indices between peak inspiration and peak expiration were Delta HI = 1.1 (0.7-1.6, p < .001), Delta CI = 4.8% (1.3-7.5%, p < .001), Delta AI = 3.0% (1.0-5.0%, p < .001), and Delta EI = 8.0% (3.0-14.0%, p < .05). The indices varied significantly during different inspiratory phases, but not during expiration (p > .05 each). Furthermore, the dynamic evaluation revealed three distinctive movement patterns of the funnel chest. Conclusions Real-time MRI reveals patterns of chest wall motion and indicate that thoracic indices of pectus excavatum should be assessed in the end-expiratory phase of quiet expiration.
引用
收藏
页码:2128 / 2135
页数:8
相关论文
共 50 条
  • [41] ORGAN MOTION DETECTION FOR REAL-TIME MRI-GUIDED RADIOTHERAPY
    Stam, M.
    Crijns, S.
    Lagendijk, J.
    Raaymakers, B.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S21 - S22
  • [42] Evaluation of dynamic performance of structure using real-time hybrid experimental system
    Inomo, H
    Horiuchi, T
    Shiraki, W
    Dogaki, M
    Yasuda, K
    RELIABILITY AND OPTIMIZATION OF STRUCTURAL SYSTEMS, 2004, : 345 - 352
  • [43] Real-Time Error Estimation for Real-Time Motion Prediction
    Moore, D.
    Sawant, A.
    MEDICAL PHYSICS, 2015, 42 (06) : 3711 - 3711
  • [44] Real-time functional MRI using a PC cluster
    Bagarinao, E
    Matsuo, K
    Nakai, T
    CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2003, 19B (01): : 14 - 25
  • [45] Improved real-time tagged MRI using REALTAG
    Chen, Weiyi
    Lee, Nam Gyun
    Byrd, Dani
    Narayanan, Shrikanth
    Nayak, Krishna S.
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (02) : 838 - 846
  • [46] Real-time cardiac MRI using DSP's
    Morgan, PN
    Iannuzzelli, RJ
    Epstein, FH
    Balaban, RS
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (07) : 649 - 653
  • [47] Performance evaluation of real-time motion tracking using positron emission fiducial markers
    Chamberland, Marc
    Wassenaar, Richard
    Spencer, Benjamin
    Xu, Tong
    MEDICAL PHYSICS, 2011, 38 (02) : 810 - 819
  • [48] Real-Time Motion Compensation Using Optical Flow
    Benes, Radek
    Riha, Kamil
    TSP 2010: 33RD INTERNATIONAL CONFERENCE ON TELECOMMUNICATIONS AND SIGNAL PROCESSING, 2010, : 166 - 170
  • [49] Real-time motion correction using octant navigators
    van der Kouwe, A
    Dale, A
    NEUROIMAGE, 2001, 13 (06) : S48 - S48
  • [50] Real-time smart surveillance using motion analysis
    Leo, Marco
    Spagnolo, P.
    D'Orazio, T.
    Mazzeo, P. L.
    Distante, A.
    EXPERT SYSTEMS, 2010, 27 (05) : 314 - 337