Pectus excavatum in motion: dynamic evaluation using real-time MRI

被引:5
|
作者
Graefe, Daniel [1 ]
Lacher, Martin [2 ]
Martynov, Illya [2 ]
Hirsch, Franz Wolfgang [1 ]
Voit, Dirk [3 ]
Frahm, Jens [3 ]
Busse, Harald [4 ]
Sesia, Sergio Bruno [5 ]
Kraemer, Sebastian [6 ]
Zimmermann, Peter [2 ]
机构
[1] Univ Hosp, Dept Pediat Radiol, Leipzig, Germany
[2] Univ Hosp, Dept Pediat Surg, Leipzig, Germany
[3] Max Planck Inst Biophys Chem, Biomed NMR, Gottingen, Germany
[4] Univ Hosp, Dept Diagnost & Intervent Radiol, Leipzig, Germany
[5] Bern Univ Hosp, Div Gen Thorac Surg, Bern, Switzerland
[6] Univ Hosp, Dept Visceral Transplant Thorac & Vasc Surg, Div Gen Thorac Surg, Leipzig, Germany
关键词
Funnel chest; Magnetic resonance imaging; Thoracic wall; PREOPERATIVE EVALUATION; COMPUTED-TOMOGRAPHY; INDEX;
D O I
10.1007/s00330-022-09197-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives The breathing phase for the determination of thoracic indices in patients with pectus excavatum is not standardized. The aim of this study was to identify the best period for reliable assessments of morphologic indices by dynamic observations of the chest wall using real-time MRI. Methods In this prospective study, patients with pectus excavatum underwent morphologic evaluation by real-time MRI at 3 T between January 2020 and June 2021. The Haller index (HI), correction index (CI), modified asymmetry index (AI), and modified eccentricity index (EI) were determined during free, quiet, and forced breathing respectively. Breathing-related differences in the thoracic indices were analyzed with the Wilcoxon signed-rank test. Motion of the anterior chest wall was analyzed as well. Results A total of 56 patients (11 females and 45 males, median age 15.4 years, interquartile range 14.3-16.9) were included. In quiet expiration, the median HI in the cohort equaled 5.7 (4.5-7.2). The median absolute differences (Delta) in the thoracic indices between peak inspiration and peak expiration were Delta HI = 1.1 (0.7-1.6, p < .001), Delta CI = 4.8% (1.3-7.5%, p < .001), Delta AI = 3.0% (1.0-5.0%, p < .001), and Delta EI = 8.0% (3.0-14.0%, p < .05). The indices varied significantly during different inspiratory phases, but not during expiration (p > .05 each). Furthermore, the dynamic evaluation revealed three distinctive movement patterns of the funnel chest. Conclusions Real-time MRI reveals patterns of chest wall motion and indicate that thoracic indices of pectus excavatum should be assessed in the end-expiratory phase of quiet expiration.
引用
收藏
页码:2128 / 2135
页数:8
相关论文
共 50 条
  • [21] Motion detection of articulatory movement with paralinguistic information using real-time MRI movie
    Asai, Takuya
    Kikuchi, Hideaki
    Maekawa, Kikuo
    2019 22ND CONFERENCE OF THE ORIENTAL COCOSDA INTERNATIONAL COMMITTEE FOR THE CO-ORDINATION AND STANDARDISATION OF SPEECH DATABASES AND ASSESSMENT TECHNIQUES (O-COCOSDA), 2019, : 96 - 101
  • [22] Real-time MRI using gradient echoes
    Riederer, SJ
    Busse, RF
    Fain, SB
    Kruger, DG
    ULTRAFAST MAGNETIC RESONANCE IMAGING IN MEDICINE, 1999, 1192 : 103 - 109
  • [23] Dynamic real-time sensor performance evaluation
    Sudano, JJ
    PROCEEDINGS OF THE FIFTH INTERNATIONAL CONFERENCE ON INFORMATION FUSION, VOL I, 2002, : 361 - 365
  • [24] EVALUATION OF RESPIRATORY INVOLVEMENT IN INCLUSION BODY MYOSITIS USING REAL-TIME MRI
    Zeng, Rachel
    Al-Bourini, Omar
    Plantenberg, Laura
    Olgemoeller, Ulrike
    Toepert, Leonie
    Lettermann, Leon
    Hofer, Sabine
    Frahm, Jens
    Uecker, Martin
    Seif, Ali
    Schmidt, Jens
    CLINICAL AND EXPERIMENTAL RHEUMATOLOGY, 2024, 42 (02) : 502 - 502
  • [25] Dynamic keyhole: A novel method to improve MR images in the presence of respiratory motion for real-time MRI
    Lee, Danny
    Pollock, Sean
    Whelan, Brendan
    Keall, Paul
    Kim, Taeho
    MEDICAL PHYSICS, 2014, 41 (07)
  • [26] Dynamic imaging and real-time inferential modeling of liver motion with external surrogates and fast-MRI
    D'Souza, W. D.
    Van Liew, S.
    Mc Avoy, T. J.
    Gullapalli, R. P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S67 - S67
  • [27] Real-Time motion blur using triangular motion paths
    Hong M.
    Oh K.
    Journal of Information Processing Systems, 2017, 13 (04): : 818 - 833
  • [28] Tear transit time evaluation using real-time technique for dynamic MR dacryocystography
    Singh, Swati
    Dhull, Anuj
    Selva, Dinesh
    Ali, Mohammad Javed
    ORBIT-THE INTERNATIONAL JOURNAL ON ORBITAL DISORDERS-OCULOPLASTIC AND LACRIMAL SURGERY, 2021, 40 (01): : 34 - 38
  • [29] Predictive Tracking for Real-Time Deformable Motion Using a Dynamic Virtual Patient Model
    Guo, B.
    Xu, X.
    Shi, C.
    MEDICAL PHYSICS, 2011, 38 (06) : 3781 - +
  • [30] Real-Time Navigation in Crowded Dynamic Environments Using Gaussian Process Motion Control
    Choi, Sungjoon
    Kim, Eunwoo
    Oh, Songhwai
    2014 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2014, : 3221 - 3226