Validation of the spectral reconstruction of an electron beam by comparison with spectrum from Monte Carlo

被引:0
|
作者
Wilches-Visbal, Jorge H. [1 ]
Apaza-Veliz, Danny G. [1 ]
机构
[1] Univ Magdalena, Fac Ciencias Salud, Santa Marta, Colombia
来源
INGENIERIA Y COMPETITIVIDAD | 2023年 / 25卷 / 01期
关键词
Depth dose percentage; dose profile; reverse reconstruction; Monte Carlo validation; gamma index; STOPPING-POWER RATIOS; ENERGY-SPECTRUM; PHOTON;
D O I
10.25100/iyc.v24i1.112051
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Inverse reconstruction, one of the ways of calculating the energy spectrum of the central axis, has shown good results in various studies. Its validation, in the absence of the real spectrum and practicality, is usually done by comparing the PDP measured in the clinic, using the gamma index. The objective of the work is to validate the spectral reconstruction of a 6MeV electron beam from a Sinergy linear accelerator, by comparison with the spectrum derived from the Monte Carlo simulation of the accelerator head, as well as to carry out an analysis of its relationship with the validation by means of the clinically accepted gamma index criterion (>95% within 3% dose difference/3 mm in distance to agreement). The inverse reconstruction used Tikhonov regularization and generalized simulated annealing. Excellent agreement was observed between the PDP and the reconstructed dose profile (obtained from the reconstructed spectrum) and the measured and simulated PDPs (from the head simulation spectrum), as passage was >95% within of 1%/1mm and 2%/2mm for the PDPs and the dose profile, respectively. The simulated and reconstructed spectra presented similar shapes, coinciding in most probable energy and much of the low energy region. Despite serious discrepancies in the peak region, this was not reflected in clinically observable differences. In conclusion, it was verified that the reconstructed spectrum is close to one simulated by Monte Carlo, making it appropriate for clinical and research use.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] A Monte Carlo Based Approach to Electron Beam Treatment Planning
    Mitrou, E.
    Alexander, A.
    Deblois, F.
    Thebaut, J.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [32] Characterising an electron pencil beam: Monte Carlo vs measurement
    Ebert, M
    Barnes, M
    MEDICAL PHYSICS, 2005, 32 (06) : 2015 - 2016
  • [33] Electron beam modeling and commissioning for Monte Carlo treatment planning
    Jiang, SB
    Kapur, A
    Ma, CM
    MEDICAL PHYSICS, 2000, 27 (01) : 180 - 191
  • [34] Monte Carlo simulation of electron beam air plasma characteristics
    邓永锋
    韩先伟
    谭畅
    Chinese Physics B, 2009, (09) : 3870 - 3876
  • [35] Auger electron from silicon: Comparison of full Monte Carlo simulations with experiment
    Chaoui, Zine-El-Abidine
    Goto, Keisuke
    SURFACE AND INTERFACE ANALYSIS, 2010, 42 (6-7) : 1105 - 1108
  • [36] Modeling electron transport and Monte Carlo calculations for electron beam dosimetry (WIP)
    Vonk, DT
    Rez, P
    Sapareto, S
    MEDICAL PHYSICS, 2003, 30 (06) : 1513 - 1513
  • [37] Evaluation of an electron Monte Carlo dose calculation algorithm for electron beam radiotherapy
    Hu, A.
    Song, H.
    Chen, Z.
    Zhou, S.
    Yin, F.
    MEDICAL PHYSICS, 2006, 33 (06) : 2099 - 2099
  • [38] Analysis of the Gamma spectrum using Monte Carlo simulation and Gaussian reconstruction
    Ye E.
    Chen F.
    Lai Y.
    Liu J.
    Harbin Gongcheng Daxue Xuebao/Journal of Harbin Engineering University, 2023, 44 (12): : 2232 - 2238
  • [39] Validation of BEAMnrc Monte Carlo model for a 12 MV photon beam
    Mohammed, Maged
    El Bardouni, T.
    Chakir, E.
    Saeed, M.
    Jamal, Al Zain
    Mohamed, Landour
    JOURNAL OF KING SAUD UNIVERSITY SCIENCE, 2018, 30 (04) : 537 - 543
  • [40] Monte Carlo model of the studsvik BNCT clinical beam:: Description and validation
    Giusti, V
    af Rosenschöld, PMM
    Sköld, K
    Montagnini, B
    Capala, J
    MEDICAL PHYSICS, 2003, 30 (12) : 3107 - 3117