Validation of the spectral reconstruction of an electron beam by comparison with spectrum from Monte Carlo

被引:0
|
作者
Wilches-Visbal, Jorge H. [1 ]
Apaza-Veliz, Danny G. [1 ]
机构
[1] Univ Magdalena, Fac Ciencias Salud, Santa Marta, Colombia
来源
INGENIERIA Y COMPETITIVIDAD | 2023年 / 25卷 / 01期
关键词
Depth dose percentage; dose profile; reverse reconstruction; Monte Carlo validation; gamma index; STOPPING-POWER RATIOS; ENERGY-SPECTRUM; PHOTON;
D O I
10.25100/iyc.v24i1.112051
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Inverse reconstruction, one of the ways of calculating the energy spectrum of the central axis, has shown good results in various studies. Its validation, in the absence of the real spectrum and practicality, is usually done by comparing the PDP measured in the clinic, using the gamma index. The objective of the work is to validate the spectral reconstruction of a 6MeV electron beam from a Sinergy linear accelerator, by comparison with the spectrum derived from the Monte Carlo simulation of the accelerator head, as well as to carry out an analysis of its relationship with the validation by means of the clinically accepted gamma index criterion (>95% within 3% dose difference/3 mm in distance to agreement). The inverse reconstruction used Tikhonov regularization and generalized simulated annealing. Excellent agreement was observed between the PDP and the reconstructed dose profile (obtained from the reconstructed spectrum) and the measured and simulated PDPs (from the head simulation spectrum), as passage was >95% within of 1%/1mm and 2%/2mm for the PDPs and the dose profile, respectively. The simulated and reconstructed spectra presented similar shapes, coinciding in most probable energy and much of the low energy region. Despite serious discrepancies in the peak region, this was not reflected in clinically observable differences. In conclusion, it was verified that the reconstructed spectrum is close to one simulated by Monte Carlo, making it appropriate for clinical and research use.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Comparison of graphite calorimeter dosimetry system with Monte Carlo simulation at an industrial electron beam accelerator
    Benny, P. G.
    Selvam, T. Palani
    Sarma, K. S. S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 703 : 98 - 101
  • [22] Validation of the electron Monte Carlo (eMC) algorithm in Eclipse 13.6
    Kelly, D.
    Meara, S.
    Fogarty, K.
    Gately, L.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S937 - S937
  • [23] Using electron beam modifiers in the DPM Monte Carlo code for electron beam treatment planning
    Tyagi, N.
    Tien, C.
    Curran, B.
    Fraass, B.
    MEDICAL PHYSICS, 2007, 34 (06) : 2502 - 2503
  • [24] Monte Carlo Modeling and Validation for MLC Based Electron Apertures
    Kaluarachchi, M.
    Schwer, M.
    Saleh, Z.
    Klein, E.
    MEDICAL PHYSICS, 2019, 46 (06) : E484 - E484
  • [25] COMPARISON OF 3-DIMENSIONAL MONTE-CARLO SIMULATION AND THE PENCIL BEAM ALGORITHM FOR AN ELECTRON-BEAM FROM A LINEAR-ACCELERATOR
    MANFREDOTTI, C
    NASTASI, U
    RAGONA, R
    ANGLESIO, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 255 (1-2): : 355 - 359
  • [26] MONTE-CARLO SIMULATIONS FOR ELECTRON-BEAM EXPOSURES
    NEUKERMANS, AP
    EATON, SG
    HEWLETT-PACKARD JOURNAL, 1981, 32 (12): : 24 - 25
  • [27] Monte Carlo simulation of electron beam lithography on topographical substrates
    Cui, Z
    MICROELECTRONIC ENGINEERING, 1998, 42 : 175 - 178
  • [28] NOVEL MONTE CARLO SIMULATION IN ELECTRON BEAM EXPOSURE.
    Wei, Mao-xin
    Wang, Jian-kun
    Qiao, Yi-zeng
    Microelectronic Engineering, 1985, 3 (1-4) : 99 - 104
  • [29] Monte Carlo simulation of electron beam air plasma characteristics
    Deng Yong-Feng
    Han Xian-Wei
    Tan Chang
    CHINESE PHYSICS B, 2009, 18 (09) : 3870 - 3876
  • [30] Fast Monte Carlo algorithms for electron beam treatment planning
    Neuenschwander, H
    Volken, W
    Cris, C
    Mini, R
    Schwab, P
    PROCEEDINGS OF THE XIITH INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY, 1997, : 23 - 26