PCB-Based Planar Inductive Loops for Partial Discharges Detection in Power Cables

被引:3
|
作者
Kaziz, Sinda [1 ,2 ]
Romano, Pietro [3 ]
Imburgia, Antonino [3 ]
Ala, Guido [3 ]
Sghaier, Halim [2 ]
Flandre, Denis [4 ]
Tounsi, Fares [1 ,4 ]
机构
[1] Univ Sfax, Ecole Natl Ingenieurs Sfax, SI2E Lab, Sfax 3038, Tunisia
[2] Univ Monastir, Fac Sci Monastir, Monastir 5019, Tunisia
[3] Univ Palermo, Dept Engn, LEPRE HV Lab, I-90128 Palermo, Italy
[4] Catholic Univ Louvain, ICTEAM Inst, SMALL Grp, B-1348 Louvain La Neuve, Belgium
关键词
inductive loops; PCB-based inductors; partial discharges; defects detection; HV power cables; INSULATION; SENSORS; MV;
D O I
10.3390/s23010290
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Partial discharge (PD) diagnosis tests, including detecting, locating, and identifying, are used to trace defects or faults and assess the degree of aging in order to monitor the insulation condition of medium- and high-voltage power cables. In this context, an experimental evaluation of three different printed circuit board (PCB)-based inductive sensor topologies, with spiral, non-spiral, and meander shapes, is performed. The aim is to assess their capabilities for PD detection along a transmission power cable. First, simulation and experimental characterization are carried out to determine the equivalent electrical circuit and the quality factor of the three sensors. PD activity was studied in the lab on a 10-m-long defective MVAC cable. The three PCB-based sensors were tested in three different positions: directly on the defective cable (P1), at a separation distance of 10 cm to 3 m (P2), and on the ground line (P3). For the three positions, all sensors' outputs present a damped sine wave signal with similar frequencies and durations. Experimental results showed that the best sensitivity was given by the non-spiral inductor, with a peak voltage of around 500 mV in P1, 428 mV in P2, and 45 mV in P3, while the meander sensor had the lowest values, which were approximately 80 mV in P1. The frequency spectrum bandwidth of all sensors was between 10 MHz and 45 MHz. The high sensitivity of the non-spiral inductor could be associated with its interesting properties in terms of quality factor and SFR, which are due to its very low resistivity. To benchmark the performance of the designed three-loop sensors, a comparison with a commercial high-frequency current transformer (HFCT) is also made.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] The effect of the operating regime of 6(10)-kV power cables on parameters of partial discharges in insulation
    Korzhov A.V.
    Kozin A.A.
    Russian Electrical Engineering, 1600, Allerton Press Incorporation (84): : 586 - 590
  • [42] Determination of Power Loop Inductance for High-Current PCB-Based Half-Bridge Circuits
    Winter, Christian
    Riedel, Jan
    Butzmann, Stefan
    2020 IEEE 21ST WORKSHOP ON CONTROL AND MODELING FOR POWER ELECTRONICS (COMPEL), 2020, : 876 - 882
  • [43] Design and characterization of a broadband PCB-based coaxial sensor for permittivity screening in skin cancer detection applications
    Fritiss, Mohamed Zied
    Poulichet, Patrick
    Takhedmit, Hakim
    Lanquetin, Laurent
    Protat, Stephane
    Vallade, Patrice
    Richalot, Elodie
    Francais, Olivier
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2023, 34 (11)
  • [44] Partial discharge combination detection with HF and UHF method for power cables
    Chen, Qing-Guo
    Pu, Jin-Yu
    Ding, Ji-Yuan
    Li, Hao
    Sun, Jian-Tao
    Zhang, Shu-Qi
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2013, 17 (04): : 39 - 44
  • [45] The Application of Partial Discharge Detection for the condition assessment of XLPE Power Cables
    Zhou, Xiaoli
    Qian, Yong
    Liu, Muqing
    PRZEGLAD ELEKTROTECHNICZNY, 2012, 88 (06): : 313 - 316
  • [46] Application of Gaussian Process Regression for Data Efficient Prediction of PCB-based Power Delivery Network Impedance Features
    Hassab, Youcef
    Schierholz, Morten
    Schuster, Christian
    2024 IEEE 28TH WORKSHOP ON SIGNAL AND POWER INTEGRITY, SPI 2024, 2024,
  • [47] Fiber Fabry-Perot sensors based acoustic detection of partial discharges in power transformers
    Li, Min
    Zhao, Hong
    Zhang, Jian
    ICPASM 2005: PROCEEDINGS OF THE 8TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 AND 2, 2006, : 254 - +
  • [48] Pattern Recognition of Partial Discharges in DC XLPE Cables Based on Convolutional Neural Network
    Zhu Y.
    Xu Y.
    Chen X.
    Sheng G.
    Jiang X.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2020, 35 (03): : 659 - 668
  • [49] Design, Fabrication, and Characterization of Archaeal Tetraether Free-Standing Planar Membranes in a PDMS- and PCB-Based Fluidic Platform
    Ren, Xiang
    Liu, Kewei
    Zhan, Qingwei
    Noh, Hongseok
    Kumbur, E. Caglan
    Yuan, Wenqiao Wayne
    Zhou, Jack G.
    Chong, Parkson Lee-Gau
    ACS APPLIED MATERIALS & INTERFACES, 2014, 6 (15) : 12618 - 12628
  • [50] Assessment of dielectric strength and partial discharges patterns in nanocomposites insulation of single-core power cables
    Thabet, Ahmed
    Fouad, M.
    JOURNAL OF ADVANCED DIELECTRICS, 2021, 11 (04)