PCB-Based Planar Inductive Loops for Partial Discharges Detection in Power Cables

被引:3
|
作者
Kaziz, Sinda [1 ,2 ]
Romano, Pietro [3 ]
Imburgia, Antonino [3 ]
Ala, Guido [3 ]
Sghaier, Halim [2 ]
Flandre, Denis [4 ]
Tounsi, Fares [1 ,4 ]
机构
[1] Univ Sfax, Ecole Natl Ingenieurs Sfax, SI2E Lab, Sfax 3038, Tunisia
[2] Univ Monastir, Fac Sci Monastir, Monastir 5019, Tunisia
[3] Univ Palermo, Dept Engn, LEPRE HV Lab, I-90128 Palermo, Italy
[4] Catholic Univ Louvain, ICTEAM Inst, SMALL Grp, B-1348 Louvain La Neuve, Belgium
关键词
inductive loops; PCB-based inductors; partial discharges; defects detection; HV power cables; INSULATION; SENSORS; MV;
D O I
10.3390/s23010290
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Partial discharge (PD) diagnosis tests, including detecting, locating, and identifying, are used to trace defects or faults and assess the degree of aging in order to monitor the insulation condition of medium- and high-voltage power cables. In this context, an experimental evaluation of three different printed circuit board (PCB)-based inductive sensor topologies, with spiral, non-spiral, and meander shapes, is performed. The aim is to assess their capabilities for PD detection along a transmission power cable. First, simulation and experimental characterization are carried out to determine the equivalent electrical circuit and the quality factor of the three sensors. PD activity was studied in the lab on a 10-m-long defective MVAC cable. The three PCB-based sensors were tested in three different positions: directly on the defective cable (P1), at a separation distance of 10 cm to 3 m (P2), and on the ground line (P3). For the three positions, all sensors' outputs present a damped sine wave signal with similar frequencies and durations. Experimental results showed that the best sensitivity was given by the non-spiral inductor, with a peak voltage of around 500 mV in P1, 428 mV in P2, and 45 mV in P3, while the meander sensor had the lowest values, which were approximately 80 mV in P1. The frequency spectrum bandwidth of all sensors was between 10 MHz and 45 MHz. The high sensitivity of the non-spiral inductor could be associated with its interesting properties in terms of quality factor and SFR, which are due to its very low resistivity. To benchmark the performance of the designed three-loop sensors, a comparison with a commercial high-frequency current transformer (HFCT) is also made.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Modeling dispersion of partial discharges due to propagation velocity variation in power cables
    Granado, J.
    Torralba, A.
    Alvarez-Arroyo, C.
    ELECTRIC POWER SYSTEMS RESEARCH, 2016, 137 : 124 - 132
  • [22] Investigations of A Simplified PCB-Based Wireless Power Resonator Operating at 13.56MHz
    Shang, Shuye
    Yang, Junxiang
    Ji, Tenghao
    Fan, Minghao
    Wang, Kaiyuan
    Wang, Heshou
    2024 10TH INTERNATIONAL CONFERENCE ON POWER ELECTRONICS SYSTEMS AND APPLICATIONS, PESA 2024, 2024,
  • [23] An Inductive Transducer for the Measurement of High Frequency Pulses with Applicability in the Detection of Partial Discharges
    Rojas, Monica
    Robles, Guillermo
    Tellini, Bernardo
    Zappacosta, Carmine
    Martinez, Juan M.
    Sanz, Javier
    2010 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE I2MTC 2010, PROCEEDINGS, 2010,
  • [24] Printed-Board Inductive Loop Topologies Performance for Partial Discharges Detection
    Imburgia, Antonino
    Kaziz, Sinda
    Romano, Pietro
    Flandre, Denis
    Artale, Giovanni
    Rizzo, Giuseppe
    Viola, Fabio
    Ala, Guido
    Tounsi, Fares
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2024, 60 (04) : 5655 - 5662
  • [25] Optical fiber sensor-based detection of partial discharges in power transformers
    Deng, JD
    Xiao, H
    Huo, W
    Luo, M
    May, R
    Wang, AB
    Liu, YL
    OPTICS AND LASER TECHNOLOGY, 2001, 33 (05): : 305 - 311
  • [26] Simulation-Driven Machine Learning for Solving the Inverse Problem of PCB-Based Tilt-Inductive Position Sensors
    Vacalebre, Antonino
    Campagna, Francesco
    Specogna, Ruben
    2024 IEEE 21ST BIENNIAL CONFERENCE ON ELECTROMAGNETIC FIELD COMPUTATION, CEFC 2024, 2024,
  • [27] A study on the measurement of partial discharges in XLPE power cables using planer loop sensors
    Lim, Kwang-Jin
    Lwin, Kyaw-Soe
    Shin, Dong-Hoon
    Park, Noh-Joon
    Park, Dae-Hee
    Hwang, Doo-Hyun
    Lim, Jong-Cheon
    PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS, 2007, : 1216 - +
  • [28] Study on Propagation Characteristics and Analysis of Partial Discharges for Electrical Treeing in XLPE Power Cables
    Zhou, Tianchun
    Liu, Ling
    Liao, Ruijin
    Chen, George
    PROCEEDINGS OF THE 2010 IEEE INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS (ICSD 2010), 2010,
  • [29] Comparative Analysis of Thermography Studies and Electrical Measurement of Partial Discharges in Underground Power Cables
    Gonzalez-Parada, A.
    Guzman-Cabrera, R.
    Torres-Cisneros, M.
    Guzman-Sepulveda, J. R.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2015, 36 (09) : 2356 - 2369
  • [30] Comparative Analysis of Thermography Studies and Electrical Measurement of Partial Discharges in Underground Power Cables
    A. Gonzalez-Parada
    R. Guzman-Cabrera
    M. Torres-Cisneros
    J. R. Guzman-Sepulveda
    International Journal of Thermophysics, 2015, 36 : 2356 - 2369