Influences on the accuracy of crystallinities determined by the method of Ruland and Vonk

被引:4
|
作者
Opdenbosch, Daniel Van [1 ]
机构
[1] Tech Univ Munich, Chair Biogen Polymers, Campus Straubing Biotechnol & Sustainabil,Schulgas, D-94315 Straubing, Germany
关键词
X-RAY DETERMINATION; CELLULOSE; ORIENTATION; DISORDER; POLYETHYLENE; SIZE;
D O I
10.1007/s10570-023-05127-6
中图分类号
TB3 [工程材料学]; TS [轻工业、手工业、生活服务业];
学科分类号
0805 ; 080502 ; 0822 ;
摘要
X-ray diffractometry is the method of choice for the determination of crystallinities in non-thermoplastic polymers, prominently in cellulose. Obtaining quantitative measures on a sound theoretical basis includes the integration of intensities scattered by the crystalline phase over volume elements in reciprocal space. This is hampered by the occurrence of diffuse scattering, whose profile is not readily distinguishable from scattering by amorphous phases. The manner of evaluating diffractograms pioneered by Ruland and refined by Vonk allows to determine crystallinities by integrating only the coherently scattered portion of crystalline-phase intensities and extrapolating their proportion to a scattering vector of 0. However, preferred crystallite orientations within measured samples, as well as the range of scattering vectors from which the data are extrapolated, have been pointed out as sources of systematic error. We investigated the influence of these factors at the examples of two crystalline structures of cellulose and two types of technically relevant thermoplastics. We found that the method of Ruland and Vonk is rather robust when applied to cellulose, but decidedly less so when applied to polymers with highly symmetric crystalline phases. We also found that there is a range of scattering vectors that leads systematically to the most accurate measures of crystallinity. We further investigated the influence of the crystallite sizes, the crystallinities themselves and the thermal displacement factors, and found that the latter had a profound effect on the accuracies of determined crystallinities.
引用
收藏
页码:4197 / 4213
页数:17
相关论文
共 50 条
  • [31] Accuracy of V determined by urea kinetic modeling
    Smye, S
    SEMINARS IN DIALYSIS, 1997, 10 (03) : 184 - 185
  • [32] Accuracy of lifetime prediction determined by fatigue monitoring
    Sanio, David
    Ahrens, Mark Alexander
    Mark, Peter
    EURODYN 2014: IX INTERNATIONAL CONFERENCE ON STRUCTURAL DYNAMICS, 2014, : 2279 - 2286
  • [33] A CATALYTIC METHOD FOR THE QUANTITATIVE-EVALUATION OF CRYSTALLINITIES OF ZSM-5 ZEOLITE PREPARATIONS
    HARDENBERG, TAJ
    MERTENS, L
    MESMAN, P
    MULLER, HC
    NICOLAIDES, CP
    ZEOLITES, 1992, 12 (06): : 685 - 689
  • [34] ACCURACY OF DISCHARGE DETERMINED FROM A RATING CURVE
    DYMOND, JR
    CHRISTIAN, R
    HYDROLOGICAL SCIENCES JOURNAL-JOURNAL DES SCIENCES HYDROLOGIQUES, 1982, 27 (04): : 493 - 504
  • [35] ACCURACY OF INTRACARDIAC INJECTIONS DETERMINED BY A POSTMORTEM STUDY
    SABIN, HI
    COGHILL, SB
    KHUNTI, K
    MCNEILL, GO
    LANCET, 1983, 2 (8358): : 1054 - 1055
  • [36] SYNTHESIS OF GEARS WITH PRE-DETERMINED ACCURACY
    KOVACS, F
    PERJU, D
    MARUSTER.S
    MISKOVIT.S
    MASCHINENBAU TECHNIK, 1970, 19 (01): : 37 - &
  • [37] Coding Accuracy Is Not Fully Determined by the Neuronal Model
    Kostal, Lubomir
    Lansky, Petr
    NEURAL COMPUTATION, 2015, 27 (05) : 1051 - 1057
  • [38] Assessment of accuracy and precision of Tc-99m-HEPIDA clearances determined by means of a simplified method
    Surma, Marian J.
    NUCLEAR MEDICINE REVIEW, 2009, 12 (01) : 14 - 22
  • [39] Evaluation of Accuracy of Stress Measurements Determined in Biaxial Stress Tests with Cruciform Specimen Using Numerical Method
    Hanabusa, Yasuhiro
    Takizawa, Hideo
    Kuwabara, Toshihiko
    STEEL RESEARCH INTERNATIONAL, 2010, 81 (09) : 1376 - 1379
  • [40] Cyclic Voltammetric Current Functions Determined with a Prescribed Accuracy by the Adaptive Huber Method for Abel Integral Equations
    Bieniasz, Leslaw K.
    ANALYTICAL CHEMISTRY, 2008, 80 (24) : 9659 - 9665