Influences on the accuracy of crystallinities determined by the method of Ruland and Vonk

被引:4
|
作者
Opdenbosch, Daniel Van [1 ]
机构
[1] Tech Univ Munich, Chair Biogen Polymers, Campus Straubing Biotechnol & Sustainabil,Schulgas, D-94315 Straubing, Germany
关键词
X-RAY DETERMINATION; CELLULOSE; ORIENTATION; DISORDER; POLYETHYLENE; SIZE;
D O I
10.1007/s10570-023-05127-6
中图分类号
TB3 [工程材料学]; TS [轻工业、手工业、生活服务业];
学科分类号
0805 ; 080502 ; 0822 ;
摘要
X-ray diffractometry is the method of choice for the determination of crystallinities in non-thermoplastic polymers, prominently in cellulose. Obtaining quantitative measures on a sound theoretical basis includes the integration of intensities scattered by the crystalline phase over volume elements in reciprocal space. This is hampered by the occurrence of diffuse scattering, whose profile is not readily distinguishable from scattering by amorphous phases. The manner of evaluating diffractograms pioneered by Ruland and refined by Vonk allows to determine crystallinities by integrating only the coherently scattered portion of crystalline-phase intensities and extrapolating their proportion to a scattering vector of 0. However, preferred crystallite orientations within measured samples, as well as the range of scattering vectors from which the data are extrapolated, have been pointed out as sources of systematic error. We investigated the influence of these factors at the examples of two crystalline structures of cellulose and two types of technically relevant thermoplastics. We found that the method of Ruland and Vonk is rather robust when applied to cellulose, but decidedly less so when applied to polymers with highly symmetric crystalline phases. We also found that there is a range of scattering vectors that leads systematically to the most accurate measures of crystallinity. We further investigated the influence of the crystallite sizes, the crystallinities themselves and the thermal displacement factors, and found that the latter had a profound effect on the accuracies of determined crystallinities.
引用
收藏
页码:4197 / 4213
页数:17
相关论文
共 50 条
  • [21] The accuracy of supermassive black hole masses determined by the single-epoch spectrum (Dibai) method
    N. G. Bochkarev
    C. M. Gaskell
    Astronomy Letters, 2009, 35 : 287 - 293
  • [22] ACCURACY OF CELL DIMENSIONS DETERMINED BY COHENS METHOD OF LEAST SQUARES AND SYSTEMATIC INDEXING OF POWDER DATA
    LANGFORD, JI
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1973, 6 (JUN1) : 190 - 196
  • [23] The accuracy of supermassive black hole masses determined by the single-epoch spectrum (Dibai) method
    Bochkarev, N. G.
    Gaskell, C. M.
    ASTRONOMY LETTERS-A JOURNAL OF ASTRONOMY AND SPACE ASTROPHYSICS, 2009, 35 (05): : 287 - 293
  • [24] Pole figure measurement plan influence on accuracy ODF coefficients determined by modified harmonic method
    Serebryany, VN
    Kurtasov, SF
    Savyolova, TI
    ICOTOM 14: TEXTURES OF MATERIALS, PTS 1AND 2, 2005, 495-497 : 1693 - 1698
  • [25] Psychophysiological stress influences temporal accuracy
    Cellini, Nicola
    Grondin, Simon
    Stablum, Franca
    Sarlo, Michela
    Mioni, Giovanna
    EXPERIMENTAL BRAIN RESEARCH, 2023, 241 (09) : 2229 - 2240
  • [26] INFLUENCES ON ACCURACY OF NUMERICALLY CONTROLLED LATHES
    RAAB, HH
    WERKSTATTSTECHNIK ZEITSCHRIFT FUR INDUSTRIELLE FERTIGUNG, 1974, 64 (04): : 208 - 211
  • [27] Psychophysiological stress influences temporal accuracy
    Nicola Cellini
    Simon Grondin
    Franca Stablum
    Michela Sarlo
    Giovanna Mioni
    Experimental Brain Research, 2023, 241 : 2229 - 2240
  • [28] Positioning control influences scanning accuracy
    O'Hare, JJ
    MANUFACTURING ENGINEERING, 2004, 132 (06): : 12 - 12
  • [29] A physical model of the thermodilution method: influences of the variations of experimental setup on the accuracy of flow rate estimation
    Ozbek, Mustafa
    Ozel, H. Fehmi
    Ekerbicer, Nuran
    Zeren, Tamer
    BIOMEDIZINISCHE TECHNIK, 2011, 56 (01): : 59 - 64
  • [30] Improving the accuracy of the transient plane source method by correcting probe heat capacity and resistance influences
    Li, Yanning
    Shi, Chunfeng
    Liu, Jian
    Liu, Errui
    Shao, Jian
    Chen, Zhi
    Dorantes-Gonzalez, Dante J.
    Hu, Xiaotang
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2014, 25 (01)