Influences on the accuracy of crystallinities determined by the method of Ruland and Vonk

被引:4
|
作者
Opdenbosch, Daniel Van [1 ]
机构
[1] Tech Univ Munich, Chair Biogen Polymers, Campus Straubing Biotechnol & Sustainabil,Schulgas, D-94315 Straubing, Germany
关键词
X-RAY DETERMINATION; CELLULOSE; ORIENTATION; DISORDER; POLYETHYLENE; SIZE;
D O I
10.1007/s10570-023-05127-6
中图分类号
TB3 [工程材料学]; TS [轻工业、手工业、生活服务业];
学科分类号
0805 ; 080502 ; 0822 ;
摘要
X-ray diffractometry is the method of choice for the determination of crystallinities in non-thermoplastic polymers, prominently in cellulose. Obtaining quantitative measures on a sound theoretical basis includes the integration of intensities scattered by the crystalline phase over volume elements in reciprocal space. This is hampered by the occurrence of diffuse scattering, whose profile is not readily distinguishable from scattering by amorphous phases. The manner of evaluating diffractograms pioneered by Ruland and refined by Vonk allows to determine crystallinities by integrating only the coherently scattered portion of crystalline-phase intensities and extrapolating their proportion to a scattering vector of 0. However, preferred crystallite orientations within measured samples, as well as the range of scattering vectors from which the data are extrapolated, have been pointed out as sources of systematic error. We investigated the influence of these factors at the examples of two crystalline structures of cellulose and two types of technically relevant thermoplastics. We found that the method of Ruland and Vonk is rather robust when applied to cellulose, but decidedly less so when applied to polymers with highly symmetric crystalline phases. We also found that there is a range of scattering vectors that leads systematically to the most accurate measures of crystallinity. We further investigated the influence of the crystallite sizes, the crystallinities themselves and the thermal displacement factors, and found that the latter had a profound effect on the accuracies of determined crystallinities.
引用
收藏
页码:4197 / 4213
页数:17
相关论文
共 50 条
  • [1] Influences on the accuracy of crystallinities determined by the method of Ruland and Vonk
    Daniel Van Opdenbosch
    Cellulose, 2023, 30 : 4197 - 4213
  • [2] Comparison of crystallinities of high density polyethylene determined by different techniques
    Middle East Technical Univ, Ankara, Turkey
    Polym Test, 2 (165-171):
  • [3] Comparison of crystallinities of high density polyethylene determined by different techniques
    Akovali, G
    Atalay, A
    POLYMER TESTING, 1997, 16 (02) : 165 - 171
  • [4] From method to critique: A reply to Vonk and van Vliet
    Wagner, W
    EUROPEAN JOURNAL OF SOCIAL PSYCHOLOGY, 1998, 28 (04) : 669 - 673
  • [5] ACCURACY OF GAS FLOWMETERS DETERMINED BY THE BUBBLE METER METHOD
    WAABEN, J
    STOKKE, DB
    BRINKLOV, MM
    BRITISH JOURNAL OF ANAESTHESIA, 1978, 50 (12) : 1251 - 1256
  • [6] ACCURACY OF STROKE INDEX AS DETERMINED BY TRANSTHORACIC ELECTRICAL IMPEDANCE METHOD
    NAGGAR, CZ
    DOBNIK, DB
    FLESSAS, AP
    KRIPKE, BJ
    RYAN, TJ
    ANESTHESIOLOGY, 1975, 42 (02) : 201 - 205
  • [7] THE DETERMINATION OF THE CRYSTALLINITY IN GLASS-CERAMIC MATERIALS BY THE METHOD OF RULAND
    VONK, CG
    FAGHERAZZI, G
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1983, 16 (APR) : 274 - 276
  • [8] Modified Vonk's Method to Determine Crystallinity and Crystal Distortion in Polymers
    Asano, Tsutomu
    Sano, Shota
    Okabe, Toshihiko
    Sano, Takumi
    Itagaki, Hideyuki
    Sawatari, Chie
    Mina, Md Forhad
    JOURNAL OF MACROMOLECULAR SCIENCE PART B-PHYSICS, 2018, 57 (05): : 317 - 332
  • [9] Method of renal function estimation influences accuracy of DOAC prescribing
    Seidi, M.
    Patel, J.
    Czuprynska, J.
    Roberts, L.
    Patel, R.
    Arya, R.
    BRITISH JOURNAL OF HAEMATOLOGY, 2016, 173 : 64 - 64
  • [10] Leveling influences accuracy
    Yost, C