Modeling and performance analysis of geothermal energy based air conditioning in building in Iraq

被引:4
|
作者
Abed, Fayadh M. [1 ]
Zaidan, Maki H. [1 ]
Hasanuzzaman, M. [2 ]
Kumar, Laveet [3 ]
Qadri, Ibrahim J. [4 ]
Jasim, Abdullah K. [1 ]
机构
[1] Tikrit Univ, Coll Engn, Tikrit, Iraq
[2] Univ Malaya, Higher Inst Ctr Excellence HICoE, UM Power Energy Dedicated Adv Ctr UMPEDAC, Wisma R&D, Level 4,Jalan Pantai Baharu, Kuala Lumpur 59990, Malaysia
[3] Mehran Univ Engn & Technol, Dept Mech Engn, Jamshoro, Pakistan
[4] Minist Water Resources, Directorate Water Resources Tuz, Tuz Khurmatu, Iraq
来源
关键词
Building air conditioning systems; Geothermal technologies; Heat exchangers; Air conditioning system; HEAT-EXCHANGER; EARTH; PROSPECTS;
D O I
10.1016/j.jobe.2023.107420
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In many desert places, like Iraq, summer lasts a long time, with a mean daily high temperature of 45 & DEG;C. Buildings use a lot of electricity to run the air conditioning systems, which is a big part of the total amount of electricity produced. Everywhere in the hot and dry subtropics, a passive method of cooling is a real way to save money on air conditioning. One of these methods, called earth pipe cooling uses the relatively constant temperature of the ground below to cool indoor spaces without using any mechanical equipment. This reduces or eliminates the building's overall energy use and impact on the environment. In a space that was 3 x 3 x 5.5 m, the temperature of the ground and the efficiency of a 31-m-long, 3-m-deep, 6-inch-wide ground heat exchanger were measured. The effect of weather on the temperature of the air coming out of a building depends on the strength of the sun, the temperature of the ocean, and the relative humidity, all of which change depending on where the building is located. Also, the output air temperature and thermal performance change concerning air moving from 4 to 6 m/s. Using MATLAB and ANSYS FLUENT, the researchers carried out the simulations of the cooling system and it was found that the theoretical results were within 1.3% of the actual results. The results showed that climate vari-ables have a big effect on the ground temperature down to a depth of 0.25 m, but at a depth of 3 m, the ground temperature remains the same (21 & DEG;C) all year long. Also, the results exhibited that the temperature of the air coming out of the system increased from 23 & DEG;C to 32 & DEG;C as the air moved faster through the system. Since the geothermal heat exchanger is most effective at cooling at a speed of 4 m/s, slowing the flow speed makes it work better. By using a geothermal heat exchanger, the difference in temperature between the inside and outside air could be cut by 10-16 & DEG;C. The data also showed that the speed and diameter of the air leaving the pipe made it hotter, while length, depth, and conductivity made it cooler.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] An Analysis of Energy Performance of a Commercial Building Using Energy Modeling
    Hamid, Mohd Fairuz Abdul
    Ramli, Nor Azuana
    Kamal, Nik Mohamad Fajarul Syawal Nik Mohd
    2017 3RD IEEE CONFERENCE ON ENERGY CONVERSION (CENCON), 2017, : 105 - 110
  • [22] Performance analysis and working fluid selection for geothermal energy-powered organic Rankine-vapor compression air conditioning
    Bu X.
    Wang L.
    Li H.
    Geothermal Energy, 1 (1)
  • [23] Modeling of Electric Vehicle Air Conditioning System and Analysis of Energy Consumption
    Nan, Jinrui
    Wang, Yao
    Chai, Zhi
    Huang, Junkui
    ELECTRICAL POWER & ENERGY SYSTEMS, PTS 1 AND 2, 2012, 516-517 : 1164 - 1170
  • [24] Energy performance evaluation and application of an air treatment system for conditioning building spaces in tropics
    Cui, X.
    Mohan, B.
    Islam, M. R.
    Chou, S. K.
    Chua, K. J.
    APPLIED ENERGY, 2017, 204 : 1500 - 1512
  • [25] Energy Performance of a University Building for Different Air Conditioning (AC) Technologies: A Case Study
    Balbis-Morejon, Milen
    Cabello-Eras, Juan Jose
    Rey-Martinez, Francisco J.
    Fandino, Jorge Mario Mendoza
    Rey-Hernandez, Javier M.
    BUILDINGS, 2024, 14 (06)
  • [26] Empirical modeling of room air conditioners for building energy analysis
    Cherem-Pereira, G.
    Mendes, N.
    ENERGY AND BUILDINGS, 2012, 47 : 19 - 26
  • [27] Energy consumption research and energy saving potential analysis for an office building Air Conditioning System
    Zhang, Xu
    Wang, Suilin
    FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 392 - 396
  • [28] Reduction of Electrical Load for Air Conditioning by Electronically Controlled Geothermal Energy
    De Nardin, C.
    Fernandes, F. T.
    Longo, A.
    Cunha, S.
    Lima, L. P.
    Farret, F. A.
    Ferranti, E. M.
    39TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2013), 2013, : 1850 - 1855
  • [29] Modeling the performance of air conditioning units based on fuzzy neural network
    Bi, HQ
    Lei, B
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 517 - 524
  • [30] An Air Conditioning Design Strategy of the Stepped Hall Based on Building Performance Simulation
    Chen, Ruijun
    Liu, Yu-Tung
    Tsay, Yaw-Shyan
    BUILDINGS, 2022, 12 (08)