Energy Performance of a University Building for Different Air Conditioning (AC) Technologies: A Case Study

被引:0
|
作者
Balbis-Morejon, Milen [1 ]
Cabello-Eras, Juan Jose [2 ]
Rey-Martinez, Francisco J. [3 ,4 ]
Fandino, Jorge Mario Mendoza [2 ]
Rey-Hernandez, Javier M. [4 ,5 ,6 ]
机构
[1] Univ Costa, DOE, Calle 58 55-66, Barranquilla 080002, Colombia
[2] Univ Cordoba, Dept Ingn Mecan, Carrera 6 77-305, Monteria 230002, Colombia
[3] Univ Valladolid, Engn Sch EII, Dept Energy & Fluid Mech, Paseo Cauce 59, Valladolid 47011, Spain
[4] Consolidated Res Unit UIC053 Castile & Leon, GIRTER Res Grp, Valladolid 47002, Spain
[5] Univ Malaga UMa, Engn Sch, Dept Mech Engn Fluid Mech & Thermal Engines, Malaga 29016, Spain
[6] GEUMA Res Grp TEP139, Malaga 29016, Spain
关键词
air conditioning systems; educational building; energy performance index (EnPI); energy simulation; life cycle cost (LCC); energy performance; HVAC; DESIGN;
D O I
10.3390/buildings14061746
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The study uses four AC technologies to assess the energy performance-this is a case study of an educational building in Barranquilla, Colombia. The building currently has split AC technology high-energy consumers. Therefore, it was necessary to assess a replacement with more efficient technology. Because of the non-seasonal climate in the building location, one month of monitoring of energy consumption was the reference for developing an energy model for the building using EnergyPlus and DesignBuilder software. The model was applied to forecast the building energy performance of our more efficient AC technologies available in the Colombian market, and valuable according to building specifications (Split, VRF, VAV, and Chiller). Results show a reduction in energy consumption of approximately 30% with the technology change and 15% savings in life cycle costs (LCCs), even though the building is already considered to have a low energy consumption according to national regulations. The findings of this study underscore the potential for widespread applicability across all types of buildings, regardless of their energy consumption profile, be it low, medium, or high. This extensive applicability not only highlights the adaptability and versatility of the technology but also underscores its significance in achieving substantial energy savings and cost reductions across the entire building industry, contributing to a more sustainable and economically efficient future.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Energy performance assessment on central air-conditioning system of commercial building: A case study in China
    Zhou Xuan
    Lian Si-zhen
    Yan Jun-wei
    Kang Ying-zi
    JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2015, 22 (08) : 3168 - 3179
  • [2] Energy performance assessment on central air-conditioning system of commercial building: A case study in China
    周璇
    练斯甄
    闫军威
    康英姿
    Journal of Central South University, 2015, 22 (08) : 3168 - 3179
  • [3] Energy performance assessment on central air-conditioning system of commercial building: A case study in China
    Xuan Zhou
    Si-zhen Lian
    Jun-wei Yan
    Ying-zi Kang
    Journal of Central South University, 2015, 22 : 3168 - 3179
  • [4] PERFORMANCE OF AIR CONDITIONING SYSTEM IN EDUCATIONAL BUILDING FOR ENERGY CONSERVATION
    Limphitakphong, Nantamol
    Chaikatetham, Nuttasate
    Khaimook, Therdthai
    Chavalparit, Orathai
    INTERNATIONAL JOURNAL OF GEOMATE, 2019, 16 (56): : 177 - 182
  • [5] Energy-saving technologies for building heating, ventilation, and air conditioning systems
    Qu M.
    Liu X.
    Yang Z.
    Wu F.
    Shi L.
    Liu X.
    Zhang T.
    Liu X.
    Jiang Y.
    Yin H.
    Annual Review of Heat Transfer, 2021, 21 : 147 - 204
  • [6] Study on the compound energy saving technology of building and air conditioning
    Feng, JM
    Lian, ZW
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 1143 - 1147
  • [7] Monthly air-conditioning energy demand calculations for building energy performance rating
    Hitchin, Roger
    BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2016, 37 (03): : 298 - 315
  • [8] Energy efficient air conditioning: case study for Kuwait
    Darwish, MA
    KUWAIT JOURNAL OF SCIENCE & ENGINEERING, 2005, 32 (02): : 209 - 222
  • [9] Effect of different building envelope materials on thermal comfort and air-conditioning energy savings: A case study in Basra city, Iraq
    Homod, Raad Z.
    Almusaed, Amjad
    Almssad, Asaad
    Jaafar, Manar K.
    Goodarzi, Marjan
    Sahari, Khairul S. M.
    JOURNAL OF ENERGY STORAGE, 2021, 34
  • [10] The role of air tightness in assessment of building energy performance: Case study of Lithuania
    Sadauskiene, J.
    Seduikyte, L.
    Paukstys, V.
    Banionis, K.
    Gailius, A.
    ENERGY FOR SUSTAINABLE DEVELOPMENT, 2016, 32 : 31 - 39