Simple analytical considerations on a thermal-flow operating parameters of a heat storage tank

被引:0
|
作者
Dolna, Oktawia [1 ]
Wisniewska, Weronika [2 ]
机构
[1] Polish Acad Sci, Ctr Heat & Power Engn, Heat Transfer Dept, Inst Fluid Flow Machinery, Fiszera 14 St, PL-80231 Gdansk, Poland
[2] Polish Acad Sci, Inst Fluid Flow Machinery, Ctr Heat & Power Engn, Turbine Dept, Fiszera 14 St, PL-80231 Gdansk, Poland
关键词
Heat storage tank; Lumped capacitance method; Dimensionless numbers; ENERGY STORAGE; STRATIFICATION; PERFORMANCE; EFFICIENCY;
D O I
10.1007/s40095-022-00516-2
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A heat storage tank (HST), described in this paper, may be applied to numerous systems used for thermal energy generation and storage. Working principle and heat-flow processes of the HST remain the same and are independent of the systems in which the HST is being used. This paper presents a thermal-flow analysis of a heat storage tank (HST) operating in an air compressor heat pump (ACHP) and a dry cooler (DC) combined cycle. The HST is operated under transient conditions for four different ACHP steady states. The HST was analysed using lumped capacitance method. The heating power of a single coil varied from 2.2 to 3.2 kW. 50% increase in mass flow rate of heating water in the coils increased the HST water mean temperature by 5.6 degrees C. A differential equation for the HST water temperature variation was solved analytically and it was presented with the use of dimensionless numbers. The presented solution is of a general form. An important parameter such as number of the coils may be varied easily. Additionally, a Mathcad computational program was proposed for the estimation of HST-ACHP-DC system thermodynamic and thermal-flow parameters. System dynamics was studied using MATLAB/Simulink. An optimal operating parameters of the HST were found and are presented in the paper. The aforementioned parameters are as follows: mass flow rates of heating and cooling media in all three coils, mass flow rate of freshwater supplying the HST, number of loops in coils and resulting heat transfer area, diameter of the loops of the coils, diameter of the coils, time after which water in the HST reaches a steady value, time period within which the HST may fulfil demand for central heating and domestic hot water (DHW) preparation without being charged simultaneously. The presented analytical model was validated based on the available data in the field literature and a high compliance was reached. For this purpose theoretical model results were compared to results of HST computational fluid dynamics (CFD) simulations. The temperature calculated using the presented model differed from the one obtained by the CFD analysis by 2.96 K.
引用
收藏
页码:387 / 403
页数:17
相关论文
共 50 条
  • [31] Thermal performance of a vertical solar hot water storage tank with a mantle heat exchanger depending on the discharging operation parameters
    Arslan, Mevlut
    Igci, Atila Abir
    SOLAR ENERGY, 2015, 116 : 184 - 204
  • [32] Simple inlet devices and hot water storage tank their influence on thermal stratification in a
    Jose Moncho-Esteve, Ignacio
    Gasque, Maria
    Gonzalez-Altozano, Pablo
    Palau-Salvador, Guillermo
    ENERGY AND BUILDINGS, 2017, 150 : 625 - 638
  • [33] Optimization of operating parameters of sinter waste heat vertical tank based on exergy efficiency
    Zhang S.
    Zhao L.
    Feng J.
    Dong H.
    Zhongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Central South University (Science and Technology), 2021, 52 (04): : 1287 - 1296
  • [34] MULTI-PHYSICS TOPOLOGY OPTIMIZATION FOR THERMAL-FLOW PROBLEMS APPLIED TO ADDITIVELY MANUFACTURED HEAT EXCHANGERS
    Tang, Tsz Ling Elaine
    Xia, Songtao
    Rop, Peter
    de Wispelaere, Steven
    Subramanian, Ramesh
    Koos, Bernd
    PROCEEDINGS OF ASME TURBO EXPO 2021: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, VOL 2D, 2021,
  • [35] Towards a better understanding of 2D thermal-flow processes in a scraped surface heat exchanger
    Blasiak, Przemyslaw
    Pietrowicz, Slawomir
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2016, 98 : 240 - 256
  • [36] NUMERICAL STUDY OF FLOW AND TEMPERATURE STRATIFICATIONS IN A LIQUID THERMAL STORAGE TANK
    GUO, KL
    WU, ST
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 1985, 107 (01): : 15 - 20
  • [37] Numerical analysis of convective flow and thermal stratification in a cryogenic storage tank
    Choi, Sung Woong
    Lee, Woo Il
    Kim, Han Sang
    NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2017, 71 (04) : 402 - 422
  • [38] Analysis of the effects of climatic conditions, loading level and operating temperature on the heat losses of two-tank thermal storage systems in CSP
    Araujo, Arthur K. A.
    Medina, Gabriel I. T.
    SOLAR ENERGY, 2018, 176 : 358 - 369
  • [39] Navier slip effect on the thermal-flow of Walters' liquid B flow due to porous stretching/shrinking with heat and mass transfer
    Anusha, T.
    Mahabaleshwar, U. S.
    Hatami, M.
    CASE STUDIES IN THERMAL ENGINEERING, 2021, 28
  • [40] Discharge of a thermal storage tank using an immersed heat exchanger with an annular baffle
    Haltiwanger, Julia F.
    Davidson, Jane H.
    SOLAR ENERGY, 2009, 83 (02) : 193 - 201