Simple analytical considerations on a thermal-flow operating parameters of a heat storage tank

被引:0
|
作者
Dolna, Oktawia [1 ]
Wisniewska, Weronika [2 ]
机构
[1] Polish Acad Sci, Ctr Heat & Power Engn, Heat Transfer Dept, Inst Fluid Flow Machinery, Fiszera 14 St, PL-80231 Gdansk, Poland
[2] Polish Acad Sci, Inst Fluid Flow Machinery, Ctr Heat & Power Engn, Turbine Dept, Fiszera 14 St, PL-80231 Gdansk, Poland
关键词
Heat storage tank; Lumped capacitance method; Dimensionless numbers; ENERGY STORAGE; STRATIFICATION; PERFORMANCE; EFFICIENCY;
D O I
10.1007/s40095-022-00516-2
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A heat storage tank (HST), described in this paper, may be applied to numerous systems used for thermal energy generation and storage. Working principle and heat-flow processes of the HST remain the same and are independent of the systems in which the HST is being used. This paper presents a thermal-flow analysis of a heat storage tank (HST) operating in an air compressor heat pump (ACHP) and a dry cooler (DC) combined cycle. The HST is operated under transient conditions for four different ACHP steady states. The HST was analysed using lumped capacitance method. The heating power of a single coil varied from 2.2 to 3.2 kW. 50% increase in mass flow rate of heating water in the coils increased the HST water mean temperature by 5.6 degrees C. A differential equation for the HST water temperature variation was solved analytically and it was presented with the use of dimensionless numbers. The presented solution is of a general form. An important parameter such as number of the coils may be varied easily. Additionally, a Mathcad computational program was proposed for the estimation of HST-ACHP-DC system thermodynamic and thermal-flow parameters. System dynamics was studied using MATLAB/Simulink. An optimal operating parameters of the HST were found and are presented in the paper. The aforementioned parameters are as follows: mass flow rates of heating and cooling media in all three coils, mass flow rate of freshwater supplying the HST, number of loops in coils and resulting heat transfer area, diameter of the loops of the coils, diameter of the coils, time after which water in the HST reaches a steady value, time period within which the HST may fulfil demand for central heating and domestic hot water (DHW) preparation without being charged simultaneously. The presented analytical model was validated based on the available data in the field literature and a high compliance was reached. For this purpose theoretical model results were compared to results of HST computational fluid dynamics (CFD) simulations. The temperature calculated using the presented model differed from the one obtained by the CFD analysis by 2.96 K.
引用
收藏
页码:387 / 403
页数:17
相关论文
共 50 条
  • [21] Experimental analysis of parameters influencing thermal stratification in single media single tank storage system with flow distributor
    Gajbhiye, Pravin
    Kedare, Shireesh
    Bose, Manaswita
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2022, 30
  • [22] Developing a simple analytical thermal model for discrete semiconductor in operating condition
    Bouguezzi, Sihem
    Ayadi, Moez
    Ghariani, Moez
    APPLIED THERMAL ENGINEERING, 2016, 100 : 155 - 169
  • [23] Reproducibility of solidification and melting processes in a latent heat thermal storage tank
    Bosholm, F.
    Lopez-Navarro, A.
    Gamarra, M.
    Corberan, J. M.
    Paya, J.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 62 : 85 - 96
  • [24] EFFECT OF SHROUD AND BAFFLE ON HEAT TRANSFER IN A SOLAR THERMAL STORAGE TANK
    Boetcher, S. K. S.
    Kulacki, F. A.
    HT2009: PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE 2009, VOL 1, 2009, : 701 - 709
  • [25] Heat loss from thermal energy storage ventilated tank foundations
    Suarez, C.
    Pino, F. J.
    Rosa, F.
    Guerra, J.
    SOLAR ENERGY, 2015, 122 : 783 - 794
  • [26] INVESTIGATION OF COMBUSTION AND THERMAL-FLOW INSIDE A PETROLEUM COKE ROTARY CALCINING KILN WITH POTENTIAL ENERGY SAVING CONSIDERATIONS
    Zhang, Zexuan
    Wang, Ting
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2011, VOL 4, PTS A AND B, 2012, : 1477 - 1489
  • [27] Investigation of Combustion and Thermal-Flow Inside a Petroleum Coke Rotary Calcining Kiln With Potential Energy Saving Considerations
    Zhang, Zexuan
    Wang, Ting
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2013, 5 (01) : 1 - 10
  • [28] On the verification of one dimensional heat flow in a horizontal thermosyphon storage tank
    Solar Energy Research Cent, Baghdad, Iraq
    Energy Convers Manage, 9 (961-974):
  • [29] On the verification of one dimensional heat flow in a horizontal thermosyphon storage tank
    Khalifa, AJN
    Mehdi, MM
    ENERGY CONVERSION AND MANAGEMENT, 1999, 40 (09) : 961 - 974
  • [30] Study on effect of tank and fin configurations and operating conditions on performance of thermal storage system
    Ramadan, Zaher
    Nguyen, Thanh Phuong
    Park, Chan Woo
    CASE STUDIES IN THERMAL ENGINEERING, 2022, 38