Simple analytical considerations on a thermal-flow operating parameters of a heat storage tank

被引:0
|
作者
Dolna, Oktawia [1 ]
Wisniewska, Weronika [2 ]
机构
[1] Polish Acad Sci, Ctr Heat & Power Engn, Heat Transfer Dept, Inst Fluid Flow Machinery, Fiszera 14 St, PL-80231 Gdansk, Poland
[2] Polish Acad Sci, Inst Fluid Flow Machinery, Ctr Heat & Power Engn, Turbine Dept, Fiszera 14 St, PL-80231 Gdansk, Poland
关键词
Heat storage tank; Lumped capacitance method; Dimensionless numbers; ENERGY STORAGE; STRATIFICATION; PERFORMANCE; EFFICIENCY;
D O I
10.1007/s40095-022-00516-2
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A heat storage tank (HST), described in this paper, may be applied to numerous systems used for thermal energy generation and storage. Working principle and heat-flow processes of the HST remain the same and are independent of the systems in which the HST is being used. This paper presents a thermal-flow analysis of a heat storage tank (HST) operating in an air compressor heat pump (ACHP) and a dry cooler (DC) combined cycle. The HST is operated under transient conditions for four different ACHP steady states. The HST was analysed using lumped capacitance method. The heating power of a single coil varied from 2.2 to 3.2 kW. 50% increase in mass flow rate of heating water in the coils increased the HST water mean temperature by 5.6 degrees C. A differential equation for the HST water temperature variation was solved analytically and it was presented with the use of dimensionless numbers. The presented solution is of a general form. An important parameter such as number of the coils may be varied easily. Additionally, a Mathcad computational program was proposed for the estimation of HST-ACHP-DC system thermodynamic and thermal-flow parameters. System dynamics was studied using MATLAB/Simulink. An optimal operating parameters of the HST were found and are presented in the paper. The aforementioned parameters are as follows: mass flow rates of heating and cooling media in all three coils, mass flow rate of freshwater supplying the HST, number of loops in coils and resulting heat transfer area, diameter of the loops of the coils, diameter of the coils, time after which water in the HST reaches a steady value, time period within which the HST may fulfil demand for central heating and domestic hot water (DHW) preparation without being charged simultaneously. The presented analytical model was validated based on the available data in the field literature and a high compliance was reached. For this purpose theoretical model results were compared to results of HST computational fluid dynamics (CFD) simulations. The temperature calculated using the presented model differed from the one obtained by the CFD analysis by 2.96 K.
引用
收藏
页码:387 / 403
页数:17
相关论文
共 50 条
  • [1] Simple analytical considerations on a thermal-flow operating parameters of a heat storage tank
    Oktawia Dolna
    Weronika Wiśniewska
    International Journal of Energy and Environmental Engineering, 2023, 14 : 387 - 403
  • [2] Thermal-Flow Analysis of a Simple LTD (Low-Temperature-Differential) Heat Engine
    Kim, Yeongmin
    Chun, Wongee
    Chen, Kuan
    ENERGIES, 2017, 10 (04):
  • [3] Heat flow in a horizontal solar thermal storage tank with an auxiliary heater
    Khalifa, AJN
    Hussian, MA
    ENERGY CONVERSION AND MANAGEMENT, 2002, 43 (04) : 549 - 555
  • [4] Characteristics of thermal-flow fields in a PECVD reactor with various operating conditions
    Baek, Jae-Sang
    Kim, Youn-Jea
    Lee, Jong-Chul
    Boo, Jin-Hyo
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2007, 51 (03) : 1113 - 1118
  • [5] Investigations of thermal-flow characteristics of minichannel evaporator of air heat pump
    Kowalczyk, Michal Jan
    Lecki, Marcin
    Romaniak, Artur
    Warwas, Bartosz
    Gutkowski, Artur
    ARCHIVES OF THERMODYNAMICS, 2021, 42 (04) : 261 - 279
  • [6] Experimental and simulation investigation on thermal performance of medium-temperature phase change heat storage tank under different operating modes and parameters
    Kong, Xiangfei
    Zhang, Chengbin
    Wang, Lu
    Yuan, Jianjuan
    JOURNAL OF ENERGY STORAGE, 2025, 113
  • [7] Investigation of thermal-flow characteristics of the minichannel heat exchanger of variable louvers height
    Romaniak, Artur
    Kowalczyk, Michal Jan
    Lecki, Marcin
    Gutkowski, Artur
    Gorecki, Grzegorz
    ARCHIVES OF THERMODYNAMICS, 2023, 44 (03) : 119 - 141
  • [8] Numerical comparison of two operating modes of thermal energy storage tank for compression heat storage in adiabatic compressed air energy storage
    Diyoke, Chidiebere
    Ngwaka, Ugochukwu
    JOURNAL OF ENERGY STORAGE, 2020, 30
  • [9] Numerical Investigation of Thermal-Flow Characteristics in Heat Exchanger with Various Tube Shapes
    Djeffal, Fares
    Bordja, Lyes
    Rebhi, Redha
    Inc, Mustafa
    Ahmad, Hijaz
    Tahrour, Farouk
    Ameur, Houari
    Menni, Younes
    Lorenzini, Giulio
    Elagan, Sayed K.
    Jawa, Taghreed M.
    APPLIED SCIENCES-BASEL, 2021, 11 (20):
  • [10] Effect Evaluation of Filling Medium Parameters on Operating and Mechanical Performances of Liquid Heavy Metal Heat Storage Tank
    Wang, Gang
    Wang, Tong
    SUSTAINABILITY, 2022, 14 (21)