Dual-energy CT iodine overlay improves efficiency of oral contrast leak assessment

被引:0
|
作者
Hinen, Shaun P. [1 ]
Griffith III, Joseph P. [1 ]
Chamberlin, Jordan [1 ]
Waltz, Jeffrey [1 ]
Kocher, Madison [1 ]
Krull, Veronica [1 ]
Young, Tristan [1 ]
Litvin, Cara B. [1 ]
Varga-Szemes, Akos [1 ]
Hardie, Andrew D. [1 ]
机构
[1] Med Univ South Carolina, Dept Radiol & Radiol Sci, 25 Courtenay St MSC 226, Charleston, SC 29401 USA
关键词
Oral contrast; leak; dual-energy computed tomography; ESOPHAGOGRAPHY; ESOPHAGECTOMY; REDUCTION;
D O I
10.1177/02841851231172771
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Evaluation for gastrointestinal leak is a frequent imaging indication, and dual-energy computed tomography (DECT) with oral or rectally administered contrast can be used to improve efficiency and diagnostic confidence. Purpose To assess the value of the DECT iodine overlay (IO) reconstruction as a stand-alone image set compared to routine CT in assessing oral or rectal contrast leak from the gastrointestinal system. Material and Methods A blinded, retrospective audit study was performed by three readers who each interpreted 50 studies performed for assessment of oral or rectal contrast leak that were acquired using DECT. Each reader independently assessed both the routine CT images and the images of the reconstructed IO for contrast leak in random order with a six-week "wash-out period" between readings. Clinical follow-up provided the reference standard. Readers recorded the presence/absence of a leak, diagnostic confidence, image quality score, and interpretation time for each image set. Results Pooled data for overall accuracy in identification of a leak increased from 0.81 (95% confidence interval [CI]=0.74-0.87) for routine CT to 0.91 (95% CI=0.85-0.95) with IO, and the area under the curve (AUC) was significantly higher for IO than routine CT (P = 0.015). Readers required significantly less time to interpret IO than routine CT (median improvement of 12.5 s per image using pooled data; P < 0.001) while maintaining diagnostic confidence and perceived image quality. Conclusion Use of DECT IO reconstructions for identification of oral or rectal contrast leak requires less time to interpret than routine CT with improved accuracy and maintained diagnostic confidence and perceived image quality.
引用
收藏
页码:2357 / 2362
页数:6
相关论文
共 50 条
  • [41] Bowel Peristalsis Artifact on Dual-Energy CT: In Vitro Study on the Influence of Different Dual-Energy CT Platforms and Enteric Contrast Agents
    Obmann, Markus M.
    Sun, Yuxin
    An, Chansik
    Ohliger, Michael A.
    Wang, Zhen J.
    Yeh, Benjamin M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2022, 218 (02) : 290 - 299
  • [42] Quantification of iodine concentration by dual-energy CT in patients with acute pancreatitis
    Utrera Perez, E.
    Tardaguila de la Fuente, G.
    Martinez Rodriguez, C.
    Villanueva Campos, A.
    Jurado Basildo, C.
    Garcia Pouton, N.
    RADIOLOGIA, 2020, 62 (05): : 360 - 364
  • [43] Use of dual-energy CT for renal mass assessment
    Shanigarn Thiravit
    Christina Brunnquell
    Larry M. Cai
    Mena Flemon
    Achille Mileto
    European Radiology, 2021, 31 : 3721 - 3733
  • [44] Use of dual-energy CT for renal mass assessment
    Thiravit, Shanigarn
    Brunnquell, Christina
    Cai, Larry M.
    Flemon, Mena
    Mileto, Achille
    EUROPEAN RADIOLOGY, 2021, 31 (06) : 3721 - 3733
  • [45] Quantitative imaging of Iodine-based contrast agent in dual-energy DBT
    Sidky, Emil Y.
    Wu, Xiangyi
    Duan, Xiaoyu
    Huang, Hailiang
    Zhao, Wei
    Zhang, Leo Y.
    Phillips, John Paul
    Zhang, Zheng
    Chen, Buxin
    Xia, Dan
    Reiser, Ingrid S.
    Pan, Xiaochuan
    17TH INTERNATIONAL WORKSHOP ON BREAST IMAGING, IWBI 2024, 2024, 13174
  • [46] Tumor hypoxia assessment using dual-energy CT derived iodine concentration in head and neck cancer
    Edmund, Jens
    Maare, Christian
    Mortensen, Henriette Klitgaard
    Skougaard, Kristin
    Lonkvist, Camilla Kjaer
    Rechner, Laura Ann
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3842 - S3845
  • [47] Correction to: Liver fibrosis assessment with multiphasic dual-energy CT: diagnostic performance of iodine uptake parameters
    Yasunori Nagayama
    Yuki Kato
    Taihei Inoue
    Takeshi Nakaura
    Seitaro Oda
    Masafumi Kidoh
    Osamu Ikeda
    Toshinori Hirai
    European Radiology, 2021, 31 : 8823 - 8824
  • [48] Iodine Images in Dual-energy CT: Detection of Hepatic Steatosis by Quantitative Iodine Concentration Values
    Beck, Stefanie
    Jahn, Laurenz
    Deniffel, Dominik
    Riederer, Isabelle
    Sauter, Andreas
    Makowski, Marcus R.
    Pfeiffer, Daniela
    JOURNAL OF DIGITAL IMAGING, 2022, 35 (06) : 1738 - 1747
  • [49] Iodine Images in Dual-energy CT: Detection of Hepatic Steatosis by Quantitative Iodine Concentration Values
    Stefanie Beck
    Laurenz Jahn
    Dominik Deniffel
    Isabelle Riederer
    Andreas Sauter
    Marcus R. Makowski
    Daniela Pfeiffer
    Journal of Digital Imaging, 2022, 35 : 1738 - 1747
  • [50] Complementary contrast media for metal artifact reduction in Dual-Energy CT
    Lambert, Jack W.
    Edic, Peter M.
    FitzGerald, Paul
    Torres, Andrew S.
    Yeh, Benjamin M.
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412