Dual-energy CT iodine overlay improves efficiency of oral contrast leak assessment

被引:0
|
作者
Hinen, Shaun P. [1 ]
Griffith III, Joseph P. [1 ]
Chamberlin, Jordan [1 ]
Waltz, Jeffrey [1 ]
Kocher, Madison [1 ]
Krull, Veronica [1 ]
Young, Tristan [1 ]
Litvin, Cara B. [1 ]
Varga-Szemes, Akos [1 ]
Hardie, Andrew D. [1 ]
机构
[1] Med Univ South Carolina, Dept Radiol & Radiol Sci, 25 Courtenay St MSC 226, Charleston, SC 29401 USA
关键词
Oral contrast; leak; dual-energy computed tomography; ESOPHAGOGRAPHY; ESOPHAGECTOMY; REDUCTION;
D O I
10.1177/02841851231172771
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Evaluation for gastrointestinal leak is a frequent imaging indication, and dual-energy computed tomography (DECT) with oral or rectally administered contrast can be used to improve efficiency and diagnostic confidence. Purpose To assess the value of the DECT iodine overlay (IO) reconstruction as a stand-alone image set compared to routine CT in assessing oral or rectal contrast leak from the gastrointestinal system. Material and Methods A blinded, retrospective audit study was performed by three readers who each interpreted 50 studies performed for assessment of oral or rectal contrast leak that were acquired using DECT. Each reader independently assessed both the routine CT images and the images of the reconstructed IO for contrast leak in random order with a six-week "wash-out period" between readings. Clinical follow-up provided the reference standard. Readers recorded the presence/absence of a leak, diagnostic confidence, image quality score, and interpretation time for each image set. Results Pooled data for overall accuracy in identification of a leak increased from 0.81 (95% confidence interval [CI]=0.74-0.87) for routine CT to 0.91 (95% CI=0.85-0.95) with IO, and the area under the curve (AUC) was significantly higher for IO than routine CT (P = 0.015). Readers required significantly less time to interpret IO than routine CT (median improvement of 12.5 s per image using pooled data; P < 0.001) while maintaining diagnostic confidence and perceived image quality. Conclusion Use of DECT IO reconstructions for identification of oral or rectal contrast leak requires less time to interpret than routine CT with improved accuracy and maintained diagnostic confidence and perceived image quality.
引用
收藏
页码:2357 / 2362
页数:6
相关论文
共 50 条
  • [31] In Vivo Differentiation of Complementary Contrast Media at Dual-Energy CT
    Mongan, John
    Rathnayake, Samira
    Fu, Yanjun
    Wang, Runtang
    Jones, Ella F.
    Gao, Dong-Wei
    Yeh, Benjamin M.
    RADIOLOGY, 2012, 265 (01) : 267 - 272
  • [32] Quantifying iodine concentration in the normal bowel wall using dual-energy CT: influence of patient and contrast characteristics
    Majida Nehnahi
    Gabriel Simon
    Romain Moinet
    Gael Piton
    Camille Camelin
    Maxime Ronot
    Éric Delabrousse
    Paul Calame
    Scientific Reports, 13
  • [33] Optimizing dual-energy CT technique for iodine-based contrast-to-noise ratio, a theoretical study
    Terzioglu, Fatma
    Sidky, Emil Y.
    Phillips, John Paul
    Reiser, Ingrid S.
    Bal, Guillaume
    Pan, Xiaochuan
    MEDICAL PHYSICS, 2024, 51 (04) : 2871 - 2881
  • [34] Quantifying iodine concentration in the normal bowel wall using dual-energy CT: influence of patient and contrast characteristics
    Nehnahi, Majida
    Simon, Gabriel
    Moinet, Romain
    Piton, Gael
    Camelin, Camille
    Ronot, Maxime
    Delabrousse, Eric
    Calame, Paul
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [35] Comparison of dual-energy CT-derived iodine content and iodine overlay of normal, inflammatory and metastatic squamous cell carcinoma cervical lymph nodes
    Tawfik, Ahmed M.
    Razek, A. A.
    Kerl, J. Matthias
    Nour-Eldin, N. E.
    Bauer, Ralf
    Vogl, Thomas J.
    EUROPEAN RADIOLOGY, 2014, 24 (03) : 574 - 580
  • [36] Comparison of dual-energy CT-derived iodine content and iodine overlay of normal, inflammatory and metastatic squamous cell carcinoma cervical lymph nodes
    Ahmed M. Tawfik
    A. A. Razek
    J. Matthias Kerl
    N. E. Nour-Eldin
    Ralf Bauer
    Thomas J. Vogl
    European Radiology, 2014, 24 : 574 - 580
  • [37] Dual energy iodine contrast CT with monochromatic x rays
    Dilmanian, FA
    Wu, XY
    Kress, J
    Ren, B
    Chapman, D
    Coderre, JA
    Greenberg, D
    Parsons, E
    Shleifer, M
    Slatkin, DN
    Thomlinson, WC
    Zhong, Z
    Button, TM
    Giron, F
    Liang, J
    Petersen, MJ
    Roque, CT
    Miller, MH
    Weedon, H
    Krus, DJ
    Perna, L
    Yamamoto, K
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 1392 - 1396
  • [38] Use of Dual-Energy CT and Iodine Maps in Evaluation of Bowel Disease
    Fulwadhva, Urvi P.
    Wortman, Jeremy R.
    Sodickson, Aaron D.
    RADIOGRAPHICS, 2016, 36 (02) : 393 - 406
  • [39] Dual-energy CT iodine quantification for characterizing focal thyroid lesions
    Lee, Do Hyung
    Lee, Young Hen
    Seo, Hyung Suk
    Lee, Ki Yeol
    Suh, Sang-il
    Ryoo, Inseon
    You, Sung-Hye
    Kim, Byungjun
    Yang, Kyung-Sook
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2019, 41 (04): : 1024 - 1031
  • [40] Spectral Imaging of Iodine and Gadolinium Nanoparticles Using Dual-Energy CT
    Badea, C. T.
    Holbrook, M.
    Clark, D. P.
    Ghaghada, K.
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573