Non-Enzymatic CO3O4 Nanostructure-Based Electrochemical Sensor for H2O2 Detection

被引:2
|
作者
Mizers, V. [1 ]
Gerbreders, V. [1 ]
Krasovska, M. [1 ]
Sledevskis, E. [1 ]
Mihailova, I. [1 ]
Ogurcovs, A. [1 ,2 ]
Bulanovs, A. [1 ]
Gerbreders, A. [2 ]
机构
[1] Daugavpils Univ, Inst Life Sci & Technol, G Liberts Innovat Microscopy Ctr, Dept Technol, 1a Parades Str, LV-5401 Daugavpils, Latvia
[2] Univ Latvia, Inst Solid State Phys, 8 Kengaraga Str, LV-1063 Riga, Latvia
关键词
Electrochemical sensor; cobalt oxide; cyclic voltammetry; hydrogen peroxide; nanostructures; GRAPHENE OXIDE NANOCOMPOSITE; HYDROGEN-PEROXIDE H2O2; NANOPARTICLES; WATER; PERFORMANCE; MORPHOLOGY; ELECTRODE; SYSTEM; AU;
D O I
10.2478/lpts-2023-0037
中图分类号
O59 [应用物理学];
学科分类号
摘要
This article describes the synthesis of nanostructured cobalt oxide on iron wires and its application for the detection of hydrogen peroxide as working electrode for non-enzymatic electrochemical sensor. Cobalt oxide was obtained by the hydrothermal synthesis method using chloride and acetate anions. The resulting nanostructured coating obtained from the chloride precursor is a uniform homogeneous porous network of long nanofibers assembled into regular honey & scy;omb-like formations. In the case of an acetate precursor, instead of nanofibers, petal-like nanostructures assembled into honeycomb agglomerates are observed. The structure, surface, and composition of the obtained samples were studied using field-emission scanning electron microscopy along with energy-dispersive spectroscopy and X-ray diffractometry.The resultant nanostructured specimens were utilized to detect H2O2 electrochemically through cyclic voltammetry, differential pulse voltammetry, and i-t measurements. A comparative research has demonstrated that the nanostructures produced from the chloride precursor exhibit greater sensitivity to H2O2 and have a more appropriate morphology for designing a nanostructured sensor. A substantial linear correlation between the peak current and H2O2 concentration within the 20 to 1300 mu M range was established. The Co3O(4) electrode obtained exhibits a sensitivity of 505.11 mu A<middle dot>mM(-1), and the electroactive surface area is calculated to be 4.684 cm(2). Assuming a signal-to-noise ratio of 3, the calculated limit of detection is 1.05 mu M. According to the interference study, the prevalent interfering agents, such as ascorbic acid, uric acid, NaCl, and glucose, do not influence the electrochemical reaction. The obtained results confirm that this sensor is suitable for working with complex analytes.The actual sample assessment demonstrated a recovery rate exceeding 95 %.
引用
收藏
页码:63 / 84
页数:22
相关论文
共 50 条
  • [31] Catalytic behavior of Co3O4 in electroreduction of H2O2
    Cao, Dianxue
    Chao, Jundang
    Sun, Limei
    Wang, Guiling
    JOURNAL OF POWER SOURCES, 2008, 179 (01) : 87 - 91
  • [32] Non-enzymatic CuCr2O4/GCE amperometric sensor for high sensing and rapid detection of nM level H2O2
    Kong, De-Rui
    Xin, Yu-Ying
    Li, Bo
    Zhang, Xian-Fa
    Deng, Zhao-Peng
    Gao, Shan
    MICROCHEMICAL JOURNAL, 2023, 194
  • [33] Progress of Advanced Nanomaterials in the Non-Enzymatic Electrochemical Sensing of Glucose and H2O2
    Thatikayala, Dayakar
    Ponnamma, Deepalekshmi
    Sadasivuni, Kishor Kumar
    Cabibihan, John-John
    Al-Ali, Abdulaziz Khalid
    Malik, Rayaz A.
    Min, Booki
    BIOSENSORS-BASEL, 2020, 10 (11):
  • [34] Progress of Advanced Nanomaterials in the Non-Enzymatic Electrochemical Sensing of Glucose and H2O2
    Thatikayala D.
    Ponnamma D.
    Sadasivuni K.K.
    Cabibihan J.-J.
    Al-Ali A.K.
    Malik R.A.
    Min B.
    Biosensors, 2020, 10 (11):
  • [35] A non-enzymatic sensor for sensitive determination of H2O2 using biomimetic nanocomposite
    Mukherjee, Atripan
    Ashrafi, Amir
    Richtera, Lukas
    Adam, Vojtech
    MENDELNET 2019: PROCEEDINGS OF 26TH INTERNATIONAL PHD STUDENTS CONFERENCE, 2019, : 585 - 590
  • [36] Hydrothermally synthesized Co3O4 microflakes for supercapacitor and non-enzymatic glucose sensor
    O. C. Pore
    A. V. Fulari
    R. K. Kamble
    A. S. Shelake
    N. B. Velhal
    V. J. Fulari
    G. M. Lohar
    Journal of Materials Science: Materials in Electronics, 2021, 32 : 20742 - 20754
  • [37] Hollow Co3O4 microspheres assembled with nanocrystals for non-enzymatic glucose sensor
    Yin, Haoyong
    He, Xiaolong
    Cui, Zhenzhen
    Nie, Qiulin
    MICRO & NANO LETTERS, 2016, 11 (03): : 151 - 155
  • [38] Hydrothermally synthesized Co3O4 microflakes for supercapacitor and non-enzymatic glucose sensor
    Pore, O. C.
    Fulari, A., V
    Kamble, R. K.
    Shelake, A. S.
    Velhal, N. B.
    Fulari, V. J.
    Lohar, G. M.
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2021, 32 (15) : 20742 - 20754
  • [39] Synthesis of Bimetallic Ni-Co Phosphide Nanosheets for Electrochemical Non-Enzymatic H2O2 Sensing
    Wang, Zhi-Yuan
    Chang, Han-Wei
    Tsai, Yu-Chen
    NANOMATERIALS, 2023, 13 (01)
  • [40] Fabrication of hollow CuO/PANI hybrid nanofibers for non-enzymatic electrochemical detection of H2O2 and glucose
    Liu, Tianjiao
    Guo, Yuqi
    Zhang, Zhenfang
    Miao, Zhicong
    Zhang, Xiaoyuan
    Su, Zhiqiang