Arterial to end-tidal CO2 gradients during isocapnic hyperventilation

被引:2
|
作者
Jouwena, Jennifer [1 ,2 ,3 ]
Eerlings, Sarah A. [1 ,2 ,3 ]
De Wolf, Andre M. [4 ]
Van Hoovels, Lieve [5 ]
Neyrinck, Arne [2 ,3 ]
Van de Velde, Marc [2 ,3 ]
Hendrickx, Jan F. A. [1 ,2 ,3 ,6 ]
机构
[1] Onze Lieve Vrouw Hosp, Dept Anesthesiol, Aalst, Belgium
[2] UZLeuven, Dept Anesthesiol, Herestr 49, B-3000 Leuven, Belgium
[3] KULeuven, Dept Cardiovasc Sci, Leuven, Belgium
[4] Northwestern Univ, Feinberg Sch Med, Dept Anesthesiol, Chicago, IL 60611 USA
[5] Onze Lieve Vrouw Hosp, Dept Lab Med, Aalst, Belgium
[6] Univ Ghent, Dept Basic & Appl Med Sci, Ghent, Belgium
关键词
Isocapnic hyperventilation; Dead space ventilation; Rebreathing; Gradient; Capnometry; CO2;
D O I
10.1007/s10877-022-00893-3
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Isocapnic hyperventilation (ICHV) is occasionally used to maintain the end-expired CO2 partial pressure (PETCO2) when the inspired CO2 (PICO2) rises. Whether maintaining PETCO2 with ICHV during an increase of the PICO2 also maintains arterial PCO2 (PaCO2) remains poorly documented. 12 ASA PS I-II subjects undergoing a robot-assisted radical prostatectomy (RARP) (n = 11) or cystectomy (n = 1) under general endotracheal anesthesia with sevoflurane in O-2/air (40% inspired O-2) were enrolled. PICO2 was sequentially increased from 0 to 0.5, 1.0, 1.5 and 2% by adding CO2 to the inspiratory limb of the circle system, while increasing ventilation to a target PETCO2 of 4.7-4.9% by adjusting respiratory rate during controlled mechanical ventilation. Pa-ETCO2 gradients were determined after a 15 min equilibration period at each PICO2 level and compared using ANOVA. Mean (standard deviation) age, height, and weight were 66 (6) years, 171 (6) cm, and 75 (8) kg, respectively. Capnograms were normal and hemodynamic parameters remained stable. PETCO2 could be maintained within 4.7-4.9% in all subjects at all times except in 1 subject with 1.5% PICO2 and 5 subjects with 2.0% PICO2; data from the one subject in whom both 1.5 and 2.0% PICO2 resulted in PETCO2 > 5.1% were excluded from analysis. Pa-ETCO2 gradients did not change when PICO2 increased. The effect of a modest rise of PICO2 up to 1.5% on PETCO2 during RARP can be readily overcome by increasing ventilation without altering the Pa-ETCO2 gradients. At higher PICO2, airway pressures may become a limiting factor, which requires further study.
引用
收藏
页码:311 / 317
页数:7
相关论文
共 50 条
  • [31] Misleading end-tidal CO2 tensions
    Kerry Brandis
    Canadian Journal of Anaesthesia, 1999, 46 : 998 - 998
  • [32] Misleading end-tidal CO2 tensions
    Brandis, K
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1999, 46 (10): : 998 - 998
  • [33] THE FEF END-TIDAL CO2 DETECTOR
    WEE, MYK
    ANAESTHESIA, 1990, 45 (03) : 251 - 251
  • [34] Misleading end-tidal CO2 tensions
    Wahba, RWM
    Tessler, MJ
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1996, 43 (08): : 862 - 866
  • [35] An Update on End-Tidal CO2 Monitoring
    Selby, Samuel T.
    Abramo, Thomas
    Hobart-Porter, Nicholas
    PEDIATRIC EMERGENCY CARE, 2018, 34 (12) : 888 - 892
  • [36] Arterial to end-tidal CO2 gradient as an indicator of silent pulmonary embolism
    Taniguchi, S
    Irita, K
    Sakaguchi, Y
    Takahashi, S
    LANCET, 1996, 348 (9039): : 1451 - 1451
  • [37] CORRELATION OF END-TIDAL CO2 MEASUREMENTS TO ARTERIAL PACO(2) IN NONINTUBATED PATIENTS
    BARTON, CW
    WANG, ESJ
    ANNALS OF EMERGENCY MEDICINE, 1994, 23 (03) : 560 - 563
  • [38] End-tidal CO2 and transcutaneous CO2: Are we ready to replace arterial CO2 in awake children?
    Dicembrino, Manuela
    Alejandra Barbieri, Irene
    Pereyra, Carla
    Leske, Vivian
    PEDIATRIC PULMONOLOGY, 2021, 56 (02) : 486 - 494
  • [39] Measuring end-tidal CO2 during intentional rebreathing - Response
    Chassard, D
    Tournadre, JP
    ANESTHESIA AND ANALGESIA, 1996, 83 (03): : 660 - 660
  • [40] CORRELATION OF END-TIDAL CO2 TO CEREBRAL PERFUSION DURING CPR
    LEWIS, LM
    STOTHERT, J
    STANDEVEN, J
    CHANDEL, B
    KURTZ, M
    FORTNEY, J
    ANNALS OF EMERGENCY MEDICINE, 1992, 21 (09) : 1131 - 1134