Arterial to end-tidal CO2 gradients during isocapnic hyperventilation

被引:2
|
作者
Jouwena, Jennifer [1 ,2 ,3 ]
Eerlings, Sarah A. [1 ,2 ,3 ]
De Wolf, Andre M. [4 ]
Van Hoovels, Lieve [5 ]
Neyrinck, Arne [2 ,3 ]
Van de Velde, Marc [2 ,3 ]
Hendrickx, Jan F. A. [1 ,2 ,3 ,6 ]
机构
[1] Onze Lieve Vrouw Hosp, Dept Anesthesiol, Aalst, Belgium
[2] UZLeuven, Dept Anesthesiol, Herestr 49, B-3000 Leuven, Belgium
[3] KULeuven, Dept Cardiovasc Sci, Leuven, Belgium
[4] Northwestern Univ, Feinberg Sch Med, Dept Anesthesiol, Chicago, IL 60611 USA
[5] Onze Lieve Vrouw Hosp, Dept Lab Med, Aalst, Belgium
[6] Univ Ghent, Dept Basic & Appl Med Sci, Ghent, Belgium
关键词
Isocapnic hyperventilation; Dead space ventilation; Rebreathing; Gradient; Capnometry; CO2;
D O I
10.1007/s10877-022-00893-3
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Isocapnic hyperventilation (ICHV) is occasionally used to maintain the end-expired CO2 partial pressure (PETCO2) when the inspired CO2 (PICO2) rises. Whether maintaining PETCO2 with ICHV during an increase of the PICO2 also maintains arterial PCO2 (PaCO2) remains poorly documented. 12 ASA PS I-II subjects undergoing a robot-assisted radical prostatectomy (RARP) (n = 11) or cystectomy (n = 1) under general endotracheal anesthesia with sevoflurane in O-2/air (40% inspired O-2) were enrolled. PICO2 was sequentially increased from 0 to 0.5, 1.0, 1.5 and 2% by adding CO2 to the inspiratory limb of the circle system, while increasing ventilation to a target PETCO2 of 4.7-4.9% by adjusting respiratory rate during controlled mechanical ventilation. Pa-ETCO2 gradients were determined after a 15 min equilibration period at each PICO2 level and compared using ANOVA. Mean (standard deviation) age, height, and weight were 66 (6) years, 171 (6) cm, and 75 (8) kg, respectively. Capnograms were normal and hemodynamic parameters remained stable. PETCO2 could be maintained within 4.7-4.9% in all subjects at all times except in 1 subject with 1.5% PICO2 and 5 subjects with 2.0% PICO2; data from the one subject in whom both 1.5 and 2.0% PICO2 resulted in PETCO2 > 5.1% were excluded from analysis. Pa-ETCO2 gradients did not change when PICO2 increased. The effect of a modest rise of PICO2 up to 1.5% on PETCO2 during RARP can be readily overcome by increasing ventilation without altering the Pa-ETCO2 gradients. At higher PICO2, airway pressures may become a limiting factor, which requires further study.
引用
收藏
页码:311 / 317
页数:7
相关论文
共 50 条
  • [21] End-tidal CO2 detection during cadaveric ventilation
    Coats, T. J.
    Morgan, B.
    Robinson, C.
    Biggs, M.
    Adnan, A.
    Rutty, G.
    EMERGENCY MEDICINE JOURNAL, 2015, 32 (09) : 753 - 754
  • [22] A low end-tidal CO2/arterial CO2 ratio during cardiopulmonary resuscitation suggests pulmonary embolism
    Aagaard, Rasmus
    Lofgren, Bo
    Caap, Philip
    Mygind-Klausen, Troels
    Botker, Morten T.
    Granfeldt, Asger
    RESUSCITATION, 2018, 133 : 137 - 140
  • [23] PREDICTABILITY OF THE ARTERIAL TO END-TIDAL CO2 PARTIAL-PRESSURE DIFFERENCE DURING ANESTHESIA
    FREI, FJ
    KONRAD, R
    ANAESTHESIST, 1990, 39 (02): : 101 - 106
  • [24] End-tidal CO2 after CO2 embolism
    Jose Eduardo Tanus-Santos
    Canadian Journal of Anaesthesia, 1998, 45 : 913 - 914
  • [25] End-tidal CO2 after CO2 embolism
    Tanus-Santos, JE
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1998, 45 (09): : 913 - 914
  • [26] ARTERIAL TO END-TIDAL CARBON-DIOXIDE GRADIENTS
    SOSIS, M
    ANESTHESIA AND ANALGESIA, 1988, 67 (05): : 486 - 486
  • [27] Arterial to end-tidal gradients in pregnant subjects - Reply
    Cruz, AM
    Crone, LA
    Southerland, LC
    Duke, T
    Ferguson, JG
    ANESTHESIOLOGY, 1997, 87 (06) : 1597 - 1598
  • [28] Abnormal end-tidal CO2 waveforms
    Jonathan L. Benumof
    Canadian Journal of Anaesthesia, 2003, 50
  • [29] Nasal end-tidal CO2 monitoring
    Weeks, DB
    ANESTHESIOLOGY, 1998, 88 (02) : 547 - 547
  • [30] Abnormal end-tidal CO2 waveforms