High-resolution feature based central venous catheter tip detection network in X-ray images

被引:2
|
作者
Wang, Yuhan [1 ]
Lam, Hak Keung [1 ]
Hou, Zeng-Guang [2 ,3 ]
Li, Rui-Qi [2 ,3 ]
Xie, Xiao-Liang [2 ,3 ]
Liu, Shi-Qi [2 ,3 ]
机构
[1] Kings Coll London, Dept Engn, London WC2R 2LS, England
[2] Chinese Acad Sci, Inst Automat, State Key Lab Management & Control Complex Syst, Beijing 100190, Peoples R China
[3] Univ Chinese Acad Sci, Sch Artificial Intelligence, Beijing 100049, Peoples R China
基金
英国工程与自然科学研究理事会;
关键词
Catheter tip; X-ray based detection; Position detection; Convolutional Neural Network (CNN); TRACKING; POSITION;
D O I
10.1016/j.media.2023.102876
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Hospital patients can have catheters and lines inserted during the course of their admission to give medicines for the treatment of medical issues, especially the central venous catheter (CVC). However, malposition of CVC will lead to many complications, even death. Clinicians always detect the malposition based on position detection of CVC tip via X-ray images. To reduce the workload of the clinicians and the percentage of malposition occurrence, we propose an automatic catheter tip detection framework based on a convolutional neural network (CNN). The proposed framework contains three essential components which are modified HRNet, segmentation supervision module, and deconvolution module. The modified HRNet can retain high resolution features from start to end, ensuring the maintenance of precise information from the X-ray images. The segmentation supervision module can alleviate the presence of other line-like structures such as the skeleton as well as other tubes and catheters used for treatment. In addition, the deconvolution module can further increase the feature resolution on the top of the highest-resolution feature maps in the modified HRNet to get a higher-resolution heatmap of the catheter tip. A public CVC Dataset is utilized to evaluate the performance of the proposed framework. The results show that the proposed algorithm offering a mean Pixel Error of 4.11 outperforms three comparative methods (Ma's method, SRPE method, and LCM method). It is demonstrated to be a promising solution to precisely detect the tip position of the catheter in X-ray images.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] High-resolution X-ray spectroscopy of θ Carinae
    Naze, Y.
    Rauw, G.
    ASTRONOMY & ASTROPHYSICS, 2008, 490 (02) : 801 - 806
  • [32] HIGH-RESOLUTION IMAGING X-RAY DETECTOR
    KELLOGG, E
    HENRY, P
    MURRAY, S
    VANSPEYBROECK, L
    BJORKHOLM, P
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1976, 47 (03): : 282 - 290
  • [33] High-resolution compact X-ray microscopy
    Takman, P. A. C.
    Stollberg, H.
    Johansson, G. A.
    Holmberg, A.
    Lindblom, M.
    Hertz, H. M.
    JOURNAL OF MICROSCOPY, 2007, 226 (02) : 175 - 181
  • [34] A 'static' high-resolution X-ray diffractometer
    Fewster, PF
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2005, 38 : 62 - 68
  • [35] HIGH-RESOLUTION X-RAY AND ELECTRON SPECTROMETER
    ELAD, E
    NAKAMURA, M
    NUCLEAR INSTRUMENTS & METHODS, 1966, 41 (01): : 161 - +
  • [36] HIGH-RESOLUTION X-RAY CHARACTERIZATION OF MATERIALS
    LISCHKA, K
    FANTNER, EJ
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 1994, 58 (03): : 119 - 120
  • [37] HIGH-RESOLUTION X-RAY PROJECTION MICROSCOPY
    NIXON, WC
    PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL AND PHYSICAL SCIENCES, 1955, 232 (1191): : 475 - &
  • [38] HIGH-RESOLUTION X-RAY SPECTROSCOPY AT JET
    GIANNELLA, R
    JOURNAL DE PHYSIQUE, 1988, 49 (C-1): : 283 - 291
  • [39] High-resolution X-ray diffraction and imaging
    Fewster, Paul F.
    Baidakova, Marina V.
    Kyutt, Reginald
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2013, 46 : 841 - 841
  • [40] Change detection in high-resolution images based on feature importance and ensemble method
    Wang, Xin
    Du, Peijun
    Liu, Sicong
    Lu, Gang
    Gao, Xiaoming
    ARABIAN JOURNAL OF GEOSCIENCES, 2019, 12 (14)