Forehead monitoring of heart rate in neonatal intensive care

被引:1
|
作者
Stockwell, S. J. [1 ]
Kwok, T. C. [2 ]
Morgan, S. P. [1 ]
Sharkey, D. [2 ]
Hayes-Gill, B. R. [1 ]
机构
[1] Univ Nottingham, Fac Engn, Opt & Photon Res Grp, Nottingham, England
[2] Univ Nottingham, Ctr Perinatal Res Lifespan & Populat Hlth, Sch Med, Nottingham, England
基金
英国工程与自然科学研究理事会; 英国医学研究理事会;
关键词
photoplethysmogram; PPG; neonatal; heart rate; forehead; reflectance-mode; pulse oximeter Min; 5-Max; 8; NICU (neonatal intensive care unit);
D O I
10.3389/fphys.2023.1127419
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Heart rate is an extremely important physiological parameter to measure in critically unwell infants, as it is the main physiological marker that changes in response to a change in infant condition. Heart rate is routinely measured peripherally on a limb with a pulse oximeter. However, when infants are critically unwell, the blood supply to these peripheries is reduced in preference for central perfusion of vital organs such as the brain and heart. Measurement of heart rate with a reflection mode photoplethysmogram (PPG) sensor on the forehead could help minimise this problem and make it easier for other important medical equipment, such as cannulas, to be placed on the limbs. This study compares heart rates measured with a forehead-based PPG sensor against a wrist-based PPG sensor in 19 critically unwell infants in neonatal intensive care collecting 198 h of data. The two heart rates were compared using positive percentage agreement, Spearman's correlation coefficient and Bland-Altman analysis. The forehead PPG sensor showed good agreement with the wrist-based PPG sensor with limits of agreement of 8.44 bpm, bias of -0.22 bpm; positive percentage agreement of 98.87%; and Spearman's correlation coefficient of 0.9816. The analysis demonstrates that the forehead is a reliable alternative location for measuring vital signs using the PPG.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Monitoring of heart rate characteristics to detect neonatal sepsis
    Laura Rio
    Anne-Sylvie Ramelet
    Pierluigi Ballabeni
    Corinne Stadelmann
    Sandra Asner
    Eric Giannoni
    Pediatric Research, 2022, 92 : 1070 - 1074
  • [32] Heart Rate Characteristics Monitoring and Central Neonatal Apnea
    D E Lake
    K D Fairchild
    J B Delos
    H Lee
    C G Rusin
    L E Guin
    M T Clark
    J Kattwinkel
    J R Moorman
    Pediatric Research, 2011, 70 : 689 - 689
  • [33] MONITORING OF INFUSION PRESSURES IN NEONATAL INTENSIVE-CARE UNIT
    GUY, B
    DEVINCENT, JFP
    PEDIATRIE, 1992, 47 (06): : 487 - 492
  • [34] A COT MONITORING-SYSTEM FOR NEONATAL INTENSIVE-CARE
    BASS, CA
    MCINTOSH, N
    DUCKER, DA
    INTENSIVE CARE MEDICINE, 1987, 13 (06) : 436 - 436
  • [35] Arrhythmias and Cardiac Bedside Monitoring in the Neonatal Intensive Care Unit
    McMullen, Sherri L.
    CRITICAL CARE NURSING CLINICS OF NORTH AMERICA, 2016, 28 (03) : 373 - +
  • [37] EEG monitoring in the neonatal intensive care unit: A critical juncture
    Boylan, Geraldine B.
    CLINICAL NEUROPHYSIOLOGY, 2011, 122 (10) : 1905 - 1907
  • [38] An algorithm for QT interval monitoring in neonatal intensive care units
    Helfenbein, Eric D.
    Ackerman, Michael J.
    Rautaharju, Pentti M.
    Zhou, Sophia H.
    Gregg, Richard E.
    Lindauer, James M.
    Miller, David
    Wang, John J.
    Kresge, Scott S.
    Babaeizadeh, Saeed
    Feild, Dirk Q.
    Michaud, Francis P.
    JOURNAL OF ELECTROCARDIOLOGY, 2007, 40 (06) : S103 - S110
  • [39] Development of criteria for gentamicin monitoring in a neonatal intensive care unit
    Stach, Leslie M.
    Pallotto, Eugenia
    Sandritter, Tracy L.
    AMERICAN JOURNAL OF HEALTH-SYSTEM PHARMACY, 2012, 69 (15) : 1319 - 1325
  • [40] Is NIRS enough to improve hemodynamic monitoring in the neonatal intensive care?
    Gatelli, Italo Francesco
    Vitelli, Ottavio
    Martinelli, Stefano
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2022, 35 (20): : 4028 - 4029